Enquiries
Message
Home > Products > Other
water treatment plant HQ-4040DFR salt purification system sea water desalination for  water filter
  • water treatment plant HQ-4040DFR salt purification system sea water desalination for  water filter

water treatment plant HQ-4040DFR salt purification system sea water desalination for water filter

FOB Reference Price
Purchase quantity ()
Minimum order quantity
Payment
Meorient Import & Export  Co.LTD
Meorient Import & Export Co.LTD
China - Hangzhou
Trading Company
Trade Capacity
Export Percentage
Nearest Port
Hangzhou,Shanghai
Accepted Delivery Terms
Employees
5-10人
Accepted Payment Currency
USD,CNY
Average Lead Time
45 Day(s)
Certifications
Product Specifications
--
Product Description
Overview
Quick Details
Condition:
New
Applicable Industries:
Hotels, Garment Shops, Building Material Shops, Manufacturing Plant, Machinery Repair Shops, Food & Beverage Factory, Farms, Restaurant, Retail, Food Shop, Printing Shops, Construction works , Energy & Mining, Food & Beverage Shops, Advertising Company, sewage treatment
Showroom Location:
United States, Pakistan, India
Video outgoing-inspection:
Provided
Machinery Test Report:
Provided
Marketing Type:
New Product 2021
Warranty of core components:
3 years
Core Components:
Reverse osmosis plant
Place of Origin:
Guangdong, China
Brand Name:
Walchin
Material:
standard export package, Reverse osmosis plant
Weight:
3-10ton
Size:
331*100*170cm, 4 inches
Power:
1.5-30
Warranty:
1 Year
Productivity:
320L/Hour
Weight (KG):
2.7 kg
Product name:
HQ-4040
Application:
Brackish water purification
Function:
Remove Salt TDS
RO membrane:
40-40In
Technology:
USA Technology
Key words:
Waste Water Treatment Machine
Operation:
16GPM
Brand:
Walchin
Packaging & Delivery

General Specifications of Residential Membrane Elements


1.RO Element HQ-4040DFR 1)Brief Introduction Aromatic polyamide RO element is developed by Walchin for treatment of brackish water. It has the characteristics of low-pressure in operation, high permeate flow and excellent rejection performance in removing of solvable salts, TOC, sio2etc.It is especial suitable for the preparation of high purity water in electronics and power industry.


water treatment plant HQ-4040DFR salt purification system sea water desalination for  water filter from China supplier
water treatment plant HQ-4040DFR salt purification system sea water desalination for  water filter from China supplier
water treatment plant HQ-4040DFR salt purification system sea water desalination for  water filter from China supplier
water treatment plant HQ-4040DFR salt purification system sea water desalination for  water filter from China supplier
water treatment plant HQ-4040DFR salt purification system sea water desalination for  water filter from China supplier
water treatment plant HQ-4040DFR salt purification system sea water desalination for  water filter from China supplier

2)Dimensions:
water treatment plant HQ-4040DFR salt purification system sea water desalination for  water filter from China supplier
Notes: RO elements placed in pressure vessels with nominal diameter of 4(101.6mm) inches
3)Properties and Testing Conditions
water treatment plant HQ-4040DFR salt purification system sea water desalination for  water filter from China supplier
Notes: Permeate of single element may vary within [-15%]~[+15%] Testing Conditions:
Testing Pressure-psi(bar)
150(1.03)
Temperature of Testing Solution
25℃
Concentration of Testing Solution (NaCl)
1500ppm
pH of Testing Solution
7.5
Recovery of Single Element
15%

4)Working Limits
Membrane Type
Polyamide thin-film composite
Maximum Operating Temperature
45℃
Maximum Operating Pressure
600psi(4.14MPa)
Maximum Influent Flow
16GPM(3.6m³/h)
Minimum Concentrated Water Flow
3GPM(0.7m³/h)
pH Range
2-11
pH Range for Chemical Cleaning
1-13
Maximum Feed SDI
5
Maximum Feed Turbidity
1
Free Chlorine Tolerance (mg/L)
0.1
FAQ Notes : 1. Important information: (1) When the membrane system is ready to be put into operation, it is very necessary to start the reverse osmosis water treatment system correctly in order to prevent damage to the membrane elements caused by feed water overcurrent or hydraulic shock. Following the correct startup sequence helps to ensure that the system operating parameters meet the design specifications, so that the system water quality and water volume can reach the established design goals. (2) Before the membrane system starts the startup procedure for the first time, the pretreatment system debugging of the membrane system, the filling of membrane elements, the calibration of the instrument and other system inspections should be completed. 2.Operation guide: In order to prevent potential membrane damage during start-up, shutdown, cleaning or other processes, any sudden pressure or cross-flow changes in the roll element should be avoided. During the start-up process, we recommend to gradually put into operation from a static state according to the following process: (1) The feed water pressure should gradually increase within a time range of 30 to 60 seconds. (2) The value of the cross-flow velocity should be gradually reached within 15-20 seconds. (3) The product water in the first hour should be discarded. General information: (1) Once the component is wet, it should always be kept wet. (2) If the user does not strictly follow the operating limits and guidelines set by this specification, the limited warranty will be invalid. (3) When the system is shut down for a long time, in order to prevent the growth of microorganisms, it is recommended to immerse the membrane element in the protective liquid. The standard preservation solution contains 1.5% (weight) of sodium bisulfite (food grade). (4) The user should be responsible for the influence of incompatible chemicals and lubricants on the components. (5) The maximum allowable pressure drop of a single pressure vessel is 50psi (3.4 bar). (6) Avoid back pressure on the water side of the product at all times. Remark: The use of this product itself does not guarantee the effective removal of cysts and pathogens in the water. The effective removal of cysts and pathogens depends on the overall system design and system operation and maintenance.
water treatment plant HQ-4040DFR salt purification system sea water desalination for  water filter from China supplier
No desirable products?
Sourcing assistant>
How to start your business
  • Step 1
    Find your interested products by search keywords
  • Step 2
    Contact the supplier by clicking ”Enquire” or “request meeting” button, otherwise, you also could consult our import consultant.
  • Step 3
    After verifying your email, get response from suppliers or our trade manager will contact you as soon as possible
  • Step 4
    Set up meeting with the Chinese supplier without language barrier
Send Enquiry
ToLily Liu
Meorient Import & Export Co.LTD
Enquire
Popular Searches
lathersbuchertether.thermosatherosfortherusherfinetherhb thermfortherthoraether.thermoslocherfletcher