China ambulatory ultrasonic veterinary blood pressure meter finger blood pressure monitor for pets
Product Specification:
1. Measuring range:0mGs~199.9mGs
2. Frequency of the probe: 8MHz
3. Specification of the blood pressure cuff
Range: No.1 4.2cm~7.1cm
No.2 5.4cm~9.1cm
No.3 6.9cm~11.7cm
No.4 9cm~13cm
No.5 12cm~16cm
(17cm~22cm ,( No.6 :17cm~22cm optical additional charge $15)
4. Rechargeable battery voltage:7.4V ,1500mAh)
5. AC input: 100~240V 50/60Hz DC output DC8.4V,1000mA
6.Continuous working time :> 8 hours
7.Speaker: 4Ω, 1W
8.Gross Weight: 3.86kg
9.Package size: 45*35*23cm
We're a leading R&D manufacturer for Vet equipements in the world.
Wecome to visit our website: www.goldenbrains.com
Components&Product size
Doppler blood presssure meter compenents | 1.a power switch /volume control: turn on the instrument and adjust the volume. 2.the power indicator: Indicates power connected or not connected. 3.headphone jack: mainly used to connect headphones. |
Product Size | Host: 192mm (L) x 84mm (W) x 30mm (H) Probe: 20mm (D) × 120mm (L) Weight: about 300 grams (including battery and probe) Outer packing: 37cm (L) x 31cm (W) x 14cm (H) |
Product Package | aluminum box: 45*35*23cm |
Doppler Blood Pressure Meters Accessories
1. blood pressure table 2. deflation switch 3. the balloon was inflated 4. the probe 5. the cuff (pressure cuff) 6. the charging adapter 7. headphones 8. the ultrasonic coupling agent 9. the box |
( Note: The five differents specifications of the cuff is suitable for different small animals. )
The Doppler host operating instructions:
1.the probe cable to connect to the probe interface, turn the power switch, the equipment to begin testing.
2.to ensure that the power indicator is lit, turn the volume control rotation to a minimum, and then increase the volume slowly.
3. smear the ultrasound gel on the skin of the probe at the top and the measurement region.
4.the probe is placed in the measurement area, and then moved slowly to find the highest value of the Doppler sound intensity.
5.in the case of headphones are connected, automatically turn off the loudspeaker, and help us to better listen to the Doppler tone.
6.the power light does not shine, you need to recharge the battery.
Sphygmomanometer operation:
1. inflatable steps: in the case of the deflation valve closed, pinch the inflatable capsule softly, to the cuff inflated.
2. deflated steps: in accordance with the direction of the arrow, gently touch and press to release the gas switch, slowly open the deflate valve, until the cuff gas discharged; loose open air switch, put the gas valve closes automatically, can be re-inflated.
In end of deflation, continue a little harder to press the switch, the valve is fully open, remove your finger, the valve does not close automatically, this state will not be able to cuff inflation; need direction of the arrow a little harder to the touch pressure above the deflation switch in order to close the valve, the next inflation.
3,the cuff connection steps:
Clinical application skills:
1,It is recommended not tape the sensor fixed at a certain position, because of the foot or leg slightly move will cause the sensor to shake, making the arterial sound disappears; with your thumb, press and hold the sensor, if the arterial sound disappears slowly move the thumb re-positioning, than open the tape again fixed in order to save time. 2,In order to make the sensor contact with the skin as possible, you need to apply some pressure, but not too much pressure, because this may cause the artery to stop the flow.
3, It is recommended that the inspection process using headphones, and can more easily hear the Doppler tone, while prevent loudspeaker harsh sound to scare the cat to be tested; In addition, the use of headphones to check, you can also reduce the surgical procedure to sick animals caused by pressure.
4, If the use of loudspeakers, the volume adjusted to make the ears feel more comfortable on the contrary, the volume is too small will lead to miss some voice to listen to the process.
5, To the appropriate leg extension commence, because the arterial blood flow measurements of bending the legs of sick animals, will be unusual restrictions, resulting in low readings or error reading.
6,Generally require seven measurements, remove the highest and lowest values to calculate the other five times the average of measurements, this is called the systolic blood pressure values, measurement units of mm Hg; some tense cat microphone in the inspection process slowly relax down several times during testing, the first few values may be very high, behind will be low. We usually will be in front of several numerical ignored behind several times as the correct value.
Note:
A probe is used in skin, we should turn off the power switch in time after using; probe is very thin and fragile, so be sure to pay attention not to damage the top of the probe (and is also very expensive to replace them) ;
if collided with sharp objects, it is broken easily, so be careful. Ultrasonic coupling agent is usually in the testing process with the ultrasonic coupling agent, can not use ECG gel or baby oil, because these substances will corrode the sensor surface, as not only can not generate the correct Doppler tone, and it will damage the probe. When the battery power is low, the power light began to fade, and similarly, the amplifier will stop the voice, this time to recharge the battery.
Cleaning:
1. To clean up the ultrasound gel above the probe after used, use cotton balls dipped in alcohol wipe. Before the use of disinfectants or fungicides, we should ask the producer whether it is appropriate.
2. in the process of cleaning body, we need to prevent the body from water.