Features:
1:Provide LED display and local data query
2:Programmable current transformation ratio
3:Support switch input,switch output and analog output
4.There are various choices of dimensions to meet the reaquirements of different electrical circuit enclosure.
Technical index:
Accuracy Measurement :Current Class:0.5
Input Measurement:
Wiring: 3-phase 3-wire, 3-phase 4-wire
Ratio value :AC 1A AC5A
Overload: Sustained: 1.2times; Instantaneous:10times/5s
Power consumption: <0.4VA(per phase)
Impedance<20mΩ
Ferquency: 45~65Hz
Power supply:
Working range: AC/DC 80V~270V,AC220V,AC380V,AC100V
Power consumption: <4VA
Functional Module :
Communication interface: 1 loop RS-485 Communication, MODBUS-RTU protocol
Baud rate: 2400~19200bps, Default :2400bps
Switching value input : 4 loop switching value input ,dry joint.
Switching value output: 3 loop relay output, capability: AC 250V/5A. DC30V/5A
Transmission output: 3 loop analog output :0/4~20mA or 0~5/10V
Environment :
Operational environment :-10°c~+55°c
Storage environment: -25°c~+70°c
Relative humidity :<=93%, in the place without corrosive gas
Height above sea level :<=2500m
Safety:
Insulation resistance: >100MΩ
AC withstand voltage: AC 2KV
Electro Magnetic Compatibility:
Electro-Static discharge: class 4
Electrical Fast Transient pulse train : class 4
Electrical surge: class 4
Outline Dimesion
Extetrnal Dimension(mm) 120*120 80*80 96*48 96*96 80*80 48*48 120*60 160*80
Cutout Dimension(mm) 111*111 76*76 92*45 92*92 68*68 45*45 114*56 152*76
Note: The number of optional extended functions would be the maximum number we can extend in normal conditions. If you have any special request, please contact with our technical department.