600W pure sine wave DC to AC power inverter | ||||||||||||||
MODEL | NP600-112 | NP600-124 | NP600-148 | NP600-212 | NP600-224 | NP600-248 | ||||||||
Output | AC Voltage | 100/110/120VAC | 220/230/240VAC | |||||||||||
Rated Power | 600W | |||||||||||||
Surge Power | Load 120~150%(3min.);1200W(3sec;resistive) | |||||||||||||
Waveform | Pure Sine Wave(THD<3%) | |||||||||||||
Frequency | 50/60Hz ±0.05% | |||||||||||||
AC Regulation | ±5% | ±10% | ||||||||||||
Power Factor Allowed | COSθ-90°~COSθ+90° | |||||||||||||
Standard Receptacles | USA/British/Franch/Schuko /UK/Australia/Universal etc. optional | |||||||||||||
LED Indicator | Green for power on, red for faulty status | |||||||||||||
USB port | 5V 2.1A | 5V 2.1A | ------ | 5V 2.1A | 5V 2.1A | ------ | ||||||||
Input | No Load Current Draw | ≤0.60A | ≤0.60A | ≤0.60A | ≤0.60A | ≤0.60A | ≤0.60A | |||||||
DC Voltage | 12VDC | 24VDC | 48VDC | 12VDC | 24VDC | 48VDC | ||||||||
Voltage Range | 10.5~15VDC | 21~30VDC | 42~60VDC | 10.5~15VDC | 21~30VDC | 42~60VDC | ||||||||
Efficiency(Typ.) | 89%~93% | |||||||||||||
Fuse | 50A×2 | 25A×2 | 15A×2 | 50A×2 | 25A×2 | 15A×2 | ||||||||
Remote Control | Function (optional) | |||||||||||||
Protection | BAT. Low Alarm | 10.5±0.5VDC | 21±1.0VDC | 42±2.0VDC | 10.5±0.5VDC | 21±1.0VDC | 42±2.0VDC | |||||||
BAT. Low Shutdown | 10±0.5VDC | 20±1.0VDC | 40±2.0VDC | 10±0.5VDC | 20±1.0VDC | 40±2.0VDC | ||||||||
Over Load | Shut down output voltage , restart to recover | |||||||||||||
Over Voltage | 15.5±0.5VDC | 31±1.0VDC | 62±2.0VDC | 15.5±0.5VDC | 31±1.0VDC | 62±2.0VDC | ||||||||
Over Temperature | Shut down output voltage , recover automatically after temperature goes down | |||||||||||||
Output Short | Shut down output voltage , restart to recover | |||||||||||||
DC Input Reverse Polarity | By fuse | |||||||||||||
Earth Fault | Shut off o/p when the load has electrical leakage | |||||||||||||
Soft Start | Yes, 3-5 Seconds | |||||||||||||
Environment | Working Temp. | 0~+50℃ | ||||||||||||
Working Humidity | 20~90%RH non-condensing | |||||||||||||
Storage Temp.&Humidity | -30~+70℃,10~95%RH | |||||||||||||
Safety & EMC | Safety Standards | Certified UL 458(only for "GFCI" receptacles) | Certified EN 60950-1; 2006+A11: 2009+A1: 2010+A12: 2011+A2: 2013. | |||||||||||
Isolation Resistance | I/P-O/P:100M Ohms/500VDC | |||||||||||||
EMI Conduction & Radiation | Certified FCC class A | Certified EN 62040-2:2006,EN61000-3-2; EN61000-3-3; | ||||||||||||
EMS Immunity | ------ | Certified IEC61000-4-3, IEC61000-4-6 | ||||||||||||
E-MARK | ------ | Certified ECE RIO.05:2014 | ||||||||||||
Others | Dimension(L×W×H) | 250×168×96mm | ||||||||||||
Packing | 2.1kg;6pcs/13.2kg/0.054m³ | |||||||||||||
Cooling | Load control fan or by thermal control fan | |||||||||||||
Application | Home and Office appliances,Portable Power Equipment,Vehicle,Yacht and Off-Gid Solar power systems…etc. |