Gas Chromatography is widely use for trace toxics analysis, monitoring and research in environmental protection, atmosphere and water source pollution;analysis, monitoring, research of toxicological; biochemistry; clinical application; pathology and virus research; food fermentation; Petroleum & Chemical; petroleum processing; oil analysis; geology, prospecting research; organic chemistry; synthesis; health and quarantine; analysis and research of public hazard detection .
1 English Large-screen LCD display.Easy to learn.
2 with self-diagnosis, over-temperature shutdown protection, file storage, call, fifth-order temperature-programmed functions, with a single column automatic compensation function; can guarantee the stability of the temperature-programmed analysis at baseline.
instrument is equipped with dual packed column inlet capillary column three, three separate gas line.
3 region has six independent temperature control, intelligent door system after cooling is very fast; various gasification chamber, detector and amplifier are modular in design, installation and replacement is very convenient.
4 capillary with a separate analysis of the complete system, independent of the capillary split injector (including membrane cleaning, and tail blowing shunt regulator).Optional capillary split / splitless injector.
5 instrument equipped with a flame ionization detector, thermal conductivity detector, flame photometric detector, electron capture detector, nitrogen phosphorus detector five kinds of detectors, three detectors can be installed, the user can according to their own self-analysis requires optional , six-way valve may also increase the sample, like the reformer unit; detector and to achieve the series and parallel operation.
The main technical indicators
Temperature Indicators
1, Temperature Zone: Column box, injector, detector
2,Temperature range: room temperature 5 °C ~ 450 °C (increments of 1 °C)
3, Temperature accuracy: better than ± 0.1 °C
4, temperature program: Eight-order rate 0.1 °C ~ 40 °C / min (increments of 0.1 °C)
FGC-1070 detector major technical indicators
Index detector | Sensitivity | Drift | Linear |
FID flame | Mt<5 × 10-12g / s (n-hexadecane) | <0.2mv / h | > 106 |
TCD TCD | S> 10000mv.ml/mg (n-hexadecane) | <20uv | > 104 |
ECD electron capture | Mt<1 × 10-13g / ml (r-666) | <15uv | > 106 |
FPD flame photometric | Mt<2 × 10-11g / s (the thiophene S) Mt<1 × 10-11g / s (methyl parathion in P) | <3% of full scale | > 103 |
1. What's the warranty?
Normally 12 months
2.Does the power supply can customized?
YES ,if you need customized power supply,pls tell us when you put the order.
3.What's the production time?
Usually10 days for production, some equipments need extra time to debug.if have Stock can delivery within one week
4.What's the Dlivery method ?
Light-weight cargo is usually by express , Air transport and sea shipping is acceptable (provide with safty packing)
5.What's the delivery time?
According to different method and country , express will be 3~15 days
6. How to install and operate?
According to each instruction manual which sent with equipment. ( We also provide after-sale technical support)