hiv testing equipment elisa test kit hiv 1 2,
Packaging & Shipping&Delivery
Packaging | Neutral packing with cartons ; 96 tests/kit |
Shipping | According to your requirement |
Delivery | Usually 10 workdays after payment |
INTENDED USE
This EIA kit is the third generation double antigen sandwich method for the detection of circulating antibodies to Human Immunodeficiency Virus Type 1 (HIV-1) and/or Human Immunodeficiency Virus Type 2 (HIV-2) in Human serum or plasma and is indicated as a screening test for serum or plasma and as an aid in the diagnosis of potential infection with HIV-1 and/or HIV-2.
REAGENTS
Materials provided with the kits:
Item | Description | 96T | 480T |
1 | Micro titer Well | 1 | 5 |
2 | Sample Diluents | 6ml | 30ml |
3 | Enzyme Conjugate | 12ml | 60ml |
4 | Negative Control | 1ml | 5ml |
5 | Positive Control(HIV-1) | 1ml | 5ml |
6 | Positive Control(HIV-2) | 1ml | 5ml |
7 | Wash Buffer Concentrate (20x) | 30ml | 150ml |
8 | Substrate Solution A | 6ml | 30ml |
9 | Substrate Solution B | 6ml | 30ml |
10 | Stop Solution | 6ml | 30ml |
11 | User manual | 1 copy | 5 copy |
Materials required but not provided:
1. Micropipettes: 0.02, 0.05, 0.10, 0.15, 0.20, and 1.0 ml.
2. Disposable pipette tips.
3. Distilled or deionized water.
4. Humidified Box capable of maintaining 37 °C
5. Absorbent paper or paper towel.
6. Micro titer plate or strip-well washer
7. Micro titer plate reader with 450nm (or 450 nm/630 nm)wavelength
8. Timer
PRECAUTION FOR USERS
1. For in-vitro diagnostic use only.
2. Do not use kit beyond expiration date.
3. Do not mix components from kits with different lot number.
4. Avoid microbial contamination of reagents.
5. Do not pipet reagent by mouth and no smoking or eating while performing assays.
6. Wear gloves during the whole process and avoid reagents or specimen spilling-out.
7. Wipe up the spills using 5% hypochlorite solution.
8. Decontaminate all liquids or solid wastes before deposing.
SPECIMEN COLLECTION AND PREPARATION
Serum should be prepared from a whole blood specimen obtained by acceptable medical techniques. Either serum or plasma can be used in this test. Remove serum or plasma from the clot or blood cells as soon as possible to avoid hemolysis. Specimen with extensive particulate should be clarified by centrifugation prior to use. Specimen frozen at -20°C or colder may be used. Avoid repeated freeze thaw.
STORAGE OF TEST KIT
Unopened test kits should be stored at 2-8C. DO NOT FREEZE KIT COMPONNETS. The microtiter plate should be kept in a sealed bag to minimize exposure to damp air. Use up the reagents as soon as possible
after the kit is unpacked.
1.Samples:free
2.OEM services: we accept customized services, OEM Service Offered, Design Service Offered, Buyer Label Offered