Main Technical Data
category | series | parameters | note | |
|
| Input voltage(V AC) | Output voltage(V DC) |
|
Ordinary rectifier | ZL1-96 | 220±10% | 96±10% | Half wave rectifier |
| ZL1-170 | 380±10% | 170±10% |
|
| ZL2-96 | 220±10% | 96±10% | Half wave rectifier |
| ZL2-170 | 380±10% | 170±10% |
|
| ZL3 series | 220±10% | 96±10% | Half wave rectifier Built-in spark suppressor |
|
| 380±10% | 170±10% |
|
| ZL5 series | 220±10% | 198±10% | All the wave (rectifier bridge type) Built-in spark suppressor |
|
| 380±10% | 342±10% |
|
Variable pressure rectifier (after excitation) | BZL3 series | 220±10% | 198→ 96±10% | Output voltage in 1.5 seconds from the entire wave into half wave. |
|
| 380±10% | 342→170±10% |
|
Fast brake rectifier | KZL1-96 | 220±10% | 96±10% | Half wave rectifier Built-in high quality mosfet |
| KZL1-170 | 380±10% | 170±10% |
|
| KZL2-1 | 220±10% | 96±10% | Half wave rectifier Built-in schneider relays |
| KZL3 series | 220±10% | 96±10% | Half wave rectifier, high quality mosfet and spark suppressor |
Rectifier matters need attention
l rectifier input power frequency 50HZ must access the power, for bidden access frequency conversion power.
l rectifier output dc voltage must be rated voltage matching with brakes.
l rectifier maximum allowable dc current 2.5 A.
l BZL3 rectifier and brake voltage matching see table below:
name | parameters | use | |
The input voltage(V.AC) | Output voltage(V.DC) | ||
BZL3 Variable pressure rectifier | 220±10% | 198→96±10% | 1. Brake for DC170V, voltage temperature can reduce brakes. 2. Brake for DC96V, brake voltage open soon. |
380±10% | 342→170±10% | 1. Brake for DC340V, voltage temperature can reduce brakes. 2. Brake for DC170V, brake voltage open soon. |