Enquiries
Message
Home > Products > Other
high quality ISO 22412 1-10000nm Nano particle size analyzer instrument
  • high quality ISO 22412 1-10000nm Nano particle size analyzer instrument

high quality ISO 22412 1-10000nm Nano particle size analyzer instrument

FOB Reference Price
Purchase quantity ()
Minimum order quantity
Payment
Meorient Import & Export  Co.LTD
Meorient Import & Export Co.LTD
China - Hangzhou
Trading Company
Trade Capacity
Export Percentage
Nearest Port
Hangzhou,Shanghai
Accepted Delivery Terms
Employees
5-10人
Accepted Payment Currency
USD,CNY
Average Lead Time
45 Day(s)
Certifications
Product Specifications
--
Product Description
Overview
Quick Details
Place of Origin:
Shandong, China
Brand Name:
SKZ
Product name:
ISO 22412 1-10000nm Nano particle size analyzer instrument
Measuring range:
1--10000nm
Accuracy:
<1%
Repeatability:
<1%
Concentration range:
0.1mg/L --100mg/L
Detector:
Photomultiplier tube (PMT)
Scattering angle:
90°
Sample cell:
10mm*10mm , 4ml
Temperature range:
5-90 ° C (accuracy ± 0.1 ° C)
Rated voltage:
AC110V/ AC220V
Packaging & Delivery
Product Description

 

High quality ISO 22412 1-10000nm Nano particle size analyzer instrument

 

We can offer high quality 1-10000nm Nano particle size analyzerdigital  Nano particle size analyzer with high accuracy, doing Nano particle size analyzer for your best choice. 

 

Features:

*Advanced optical path design: SKZ1062C-2 adopts concentrated light Fourier transform test technology to ensure the maximum range in the shortest focal length, effectively improve the resolution of the instrument; unique high-density detection unit, so that SKZ1062C-2 has super small particles Test capability, high-density detection unit uses the SKZ1062C-2 with superior full-scale seamless testing capability.

 

* Single-lens single-lens design: The newly designed optical path adopts the latter lens acquisition technology, which realizes no blind zone detection from 0.01 to 170 degrees, and the measurement range is from 0.01 micron to 2000 micron.

 

*Aluminum alloy optical platform: high-precision all-aluminum optical platform, long-term stable and reliable; optical path system is fully enclosed, effectively solve the dust pollution problem; the instrument design meets the international laser safety regulations, with laser beam automatic protection.

 

*Operational protection function: The newly designed SKZ1062C-2 has misoperation protection function. The instrument has non-response function to the operator's wrong command, which avoids the damage of the instrument caused by misoperation and greatly improves the stability of the instrument test result.

 

* Large-caliber lens: Large-caliber Fourier transform lens, more efficient implementation of optical signal Fourier transform, more accurate and more effective.

 

* Ultrasonic anti-dry: SKZ1062C-2 realizes the waterless ultrasonic self-protection function of the sample cell to avoid damage to the ultrasound; at the same time, the ultrasonic power can be adjusted within the range of 0 to 50 watts.

 

 

* Dustproof and shockproof design: The whole instrument has been sealed and designed to greatly improve the service life of internal components. The unique suspension structure can effectively avoid the interference of external vibration to the instrument, and make the result test more stable and reliable.

 

* Strong anti-corrosion design (optional): It can be equipped with acid, alkali, oil (including all solvent oil) and organic solvent (such as acetone, phenol, n-hexane and other organic solvents) according to the actual needs of customers.

 

*Imported fiber-optic semiconductor laser: SKZ1062C-2 adopts high-stability, long-life imported high-power fiber-optic output semiconductor laser. Excellent monochromaticity and stability make SKZ1062C-2 have excellent test repeatability; laser has self-checking The power change self-regulation function keeps the laser constant power output. (wavelength 635 nm; power greater than 5 mw).

 

*Automatic alignment: The exclusive use of the combination of mechanical center and optical center, the optical path automatically adjusts the positioning more accurately, reaching the micron level; at the same time, the optical path adjustment speed is faster and faster and can be adjusted in 15 seconds. The self-developed automatic alignment system consists of stepper motor, precision guide rail, precision controller and software system. The minimum step distance is 0.2 microns, ensuring that the focus of the laser beam always passes through the center point of the detector, improving the accuracy of the test results and testing of Repeatability.

 

* Split design: SKZ1062C-2 adopts split design, the optical path part is more stable and effective, avoids the influence of the vibration of the dispersing device, and greatly improves the test repeatability of the instrument.

 

* Free bubble design: The new design makes no bubbles enter the test sample window during the whole test process, avoiding air bubble interference.

 

* Sample no residue design: The instrument pipeline and drainage structure have been optimized. There is no residual liquid in the instrument pipeline and circulating pump to avoid the impact on the next test data. The dry test also has no residue design. 

* Dry computer remote control feeding: When SKZ1062C-2 dry test, testers can control the feeding speed through the computer remotely, which greatly reduces the labor intensity of testers.

 

* Sample window quick change device: The newly designed sample window quick change device makes the sample window replacement more convenient and quick.

 

Software: Compliance with Pharmacopoeia GMP regulations, with electronic signature, permission settings, data tracking, data can not be changed and other functions.

 

Specifications:

 

Standard

ISO 13320-1:1999

Test Range

Wet method: 0.01μm-2000μm

Dry method: 0.1μm-2000μm

Number of detector channels

Wet method 127

Dry method 100

accuracy

<± 1% (national standard D50)

Repeatability

<± 0.5% (national standard D50)

Free bubble

With bubble-free design, no bubble interference data is more accurate

Misoperation protection

With a self-protection function of misoperation, and does not respond to misoperation.

Laser parameter

Imported fiber output high power laser λ= 650nm, p>10mW

Lens

Import Canon lens

Operating mode

Dry and wet software one-button automatic operation

Optical path calibration

Optical path auto-calibration

Wet dispersion

Ultrasound

Frequency: f=40KHz, power: p=80W, time: freely adjustable; with ultrasonic anti-dry

Circulation, mixing

Cycle mixing integrated design, speed: 100-3950rpm adjustable

Circulating flow

Rated flow: 0-10L/min adjustable Rated power: 25W

Sample cell

Self-designed boiling sample cell, better dispersion effect, capacity: 190-600mL can be tested normally

Shading detection

The instrument has a unique real-time detection function of opacity to ensure more accurate sample loading.

Micro-injection

Can be equipped with a micro automatic test device, 10 ml can be cycled test (optional)

Dry dispersion

Dispersion method

High pressure air dispersion

Feeding method

Mechanical stepless speed regulation vibration feeding, software control

Oil-free silent air compressor

With dust filtering to ensure test accuracy

Cold dryer

The refrigerated dryer filters the moisture in the air to ensure dispersion

Software

Analysis mode

Including free distribution, R-R distribution and lognormal distribution, according to the hierarchical statistical model, to meet the different requirements of different industries for the statistical method of sample size measurement

Statistical methods

Volume distribution and quantity distribution to meet different statistical methods for particle size distribution in different industries

Statistical comparison

Statistical comparison and analysis can be carried out for multiple test results, which can obviously compare the difference between different batches of samples, samples before and after processing and test results at different times, which has a strong practical significance for the quality control of industrial raw materials.

Self-DIY display template

The user customizes the data to be displayed, based on the particle size, the particle size according to the percentage, or the percentage according to the particle size interval to meet the characterization of the particle size test in different industries. Span, consistency, interval accumulation, etc.

Testing report

The test report can export various forms of documents such as Word, Excel, Picture (Bmp) and Text (Text), which can be used to view test reports and research results in scientific research articles in any situation.

Multi-language support

Chinese and English language interface support, and other language interfaces can be embedded according to user requirements.

Intelligent operation mode

In the real no-intervention operation, the user only needs to add the sample to be tested according to the prompt, and the test result is more repeatable.

Operating mode

computer control operation

Test speed

<1min/time (without sample dispersion time)

 

Principle:

Nano theory with full-scale, fully taking into account the refractive index of the optical properties of the particles and the dispersion medium measured particle size distribution data, depending on the size of the particles in each angle scattered light intensity changes on the anti-particle group performances.

Particle sizing calculations are generally divided into unconstrained fitting inversion and the constrained fitting inversion. Constrained fitting inversion before the calculation assumes that match a certain distribution of particle group, according to the law of inverse particle size distribution. This type of operation is relatively simple, but because of prior assumptions inevitably exists between the reality of bias, thereby testing the constrained fitting data do not reflect the actual particle size distribution of the particles.

Unconstrained fitting inversion test before the particle does not make any assumptions, by light intensity directly and accurately calculate the size distribution of particles. Such assumptions are reasonable detector and particle classification, to make high demands on the device itself. SKZ1062 laser particle size Analyzer, using optimum of non-uniform cross-dimensional fan-shaped array of detector arrays and reasonable size grading, making it possible to accurately measure particle size distribution.

               

Packaging & Shipping

 

Customer SHOW

 

FAQ

 

No desirable products?
Sourcing assistant>
How to start your business
  • Step 1
    Find your interested products by search keywords
  • Step 2
    Contact the supplier by clicking ”Enquire” or “request meeting” button, otherwise, you also could consult our import consultant.
  • Step 3
    After verifying your email, get response from suppliers or our trade manager will contact you as soon as possible
  • Step 4
    Set up meeting with the Chinese supplier without language barrier
Send Enquiry
ToLily Liu
Meorient Import & Export Co.LTD
Enquire
Popular Searches
lathersbuchertether.thermosatherosfortherusherfinetherhb thermfortherthoraether.thermoslocherfletcher