Model | Economy type | Standard type | Upgrade type |
Accuracy | ±0.5% | ±0.5% | ±0.3% |
Display | Cumulative flow: 9 digits Instantaneous flow: 5 digits | Cumulative flow: 9 digits Instantaneous flow: 5 digits | Cumulative flow: 10 digits Instantaneous flow: 5 digits |
Alarm | Empty pipe alarm Flow upper/lower limit alarm | Empty pipe alarm Flow upper/lower limit alarm | Empty pipe alarm Flow upper/lower limit alarm Excitation limit alarm |
Power failure record | - | - | YES |
Configuration | Button | Button | Infrared remote/Button |
Communication | RS485 Modbus RTU | RS485 Modbus RTU | RS485 with lighting protection HART/Profibus/Modbus optional |
Converter | ||||
Compact Type | IP65 | |||
Remote Type | IP65(IP68 optional) | |||
Measurement sensor | ||||
Nominal Diameter | DN15-DN1000 | |||
Pressure rating (High pressure can be customized) | DN6 - DN80, PN<4.0MPa | |||
DN100 - DN150, PN<1.6MPa | ||||
DN200 – DN1000, PN<1.0MPa | ||||
DN1200 – DN2000, PN<0.6MPa | ||||
Lining Material | Chloroprene rubber (CR), Polytetrafluoroethylene (PTFE/F4), Fluorinated ethylene propylene (FEP/F46), Teflon(PFA) | |||
Electrode Material | 316L Stainless Steel, Hastelloy C, Hastelloy B, Ti, Ta, Pt | |||
Ingress protection | IP68 | IP65 | ||
Medium temperature | -25 – 180℃ | -10 – 80℃ | ||
Serial communications | RS-485 | |||
Output | Current (4-20 mA) , pulse , frequency , state switch | |||
Max measuring error | Measurement value ±0.5%(Flow speed > 1m/s); Measurement value ±0.5% ±2mm/s(Flow speed <1m/s) | |||
Repetitiveness | 0.15% | |||
Power supply | 100-240VAC,50/60Hz, 22VDC—26VDC | |||
Power consumption | Max 15VA | |||
Signal cable | Apply only to remote type | |||
Shielded cable | Signal section,wire: 0.5mm2 Cu /AWG20 |