fault passage indicator for overhead lines
  • fault passage indicator for overhead lines

fault passage indicator for overhead lines

FOB Reference Price
Purchase quantity ()
Minimum order quantity
Payment
Meorient Import & Export  Co.LTD
Meorient Import & Export Co.LTD
China - Hangzhou
Trading Company
Trade Capacity
Export Percentage
Nearest Port
Hangzhou,Shanghai
Accepted Delivery Terms
Employees
5-10人
Accepted Payment Currency
USD,CNY
Average Lead Time
45 Day(s)
Certifications
Product Specifications
--
Product Description
Overview
Quick Details
Place of Origin:
China
Brand Name:
Four-Faith
Model Number:
JJZ-FFX-C/JYZ-FFX-C/JJW-FFX-C
Short circuit fault indicator:
yes
Ground fault indicator:
yes
Local fault alarm:
yes
Remote fault alarm:
yes
Supply Ability
Supply Ability:
1000 Set/Sets per Month fault passage indicator for overhead lines
Packaging & Delivery

fault passage indicator for overhead lines

 

Product Description

Smart Electricity Distribution Network Monitoring System

Smart electricity distribution network monitoring system is the use of electronic information and communication technology to detect the distribution network’s short circuits and single-phase ground faults. It enables real-time monitoring, threshold warnings, fault session detection and sending out the fault message. This allows technical personnel to arrive on-site and fix the relevant problems quickly. This system can reduce the reliance on technician experience to identify faults, increase equipment stability and management efficiency. 

                  

 

Application Scenarios

 

Widely used in cities with overhead electricity lines, cable lines, oil fields, switchgears and other boxed equipments.

                  

 

System Composition

The system consists of the fault indicator (acquisition unit), collecting unit and main station server.

Fault indicator (acquisition unit):

Fault indicator is the basis of the whole system; it’s used for collecting real-time data from all test sites.

Collecting unit: When fault indicator detects short circuit or earth fault, the turnover alarm and flashing red light will be triggered immediately, at the same time, the fault information will be transferred to the collecting unit wirelessly through 433M/Lora, and the collecting unit will report it to the main station server through GPRS/CDMA (2G/3G/4G).

Main station server: When the main station server receives the fault information, together with GIS system, the system will provide the time and location information where the fault occurs, to help the maintenance staff identify the fault and fix it in a timely manner.

Abnormal Monitoring Indicators, Automatic Flashing, Turnover Alarm And Sending To Main Station Server

 

When there is a fault in the electricity line, the LED light will flash immediately and the alarm will sound. At the same time the fault information is transmitted to the main station server. Once the fault information is received, in combination with the GIS system, the fault location and time will be sent out to a technician who will then rush on-site to fix the problem.

                                       

Visible Faulty Site and Clear Line Status

 

When the main station server receives the fault information from the terminal, it will perform a topology analysis, calculating, together with the GIS system to display the fault sites graphically, and clearly displaying the line status.

                                     

Powerful Electricity Solutions

1. Powered by electricity line: 10A+ current from the electricity line would be enough for the fault line indicator, extra battery power is not needed in this case.

 

2. Powered by solar energy: The terminal is powered by solar energy, backed up with a high-capacity lithium battery, can operate normally for 30 days in wet/raining weather conditions.

 

3. Low power optimization: The indicator uses an ultra-low power consumption design; average power consumption is less than 20 uA.

 

4. Battery power detection: System will detect power of the backup battery automatically, and will report to the main station server when the power is lower than the preset threshold value, and will have a reminder for you to change the battery.

 

Detailed image of fault passage indicator for overhead lines

 

Parameter Table of fault Indicator Features 

Product JJZ-FFX-CJJW-FFX-CJYZ-FFX-CJYW-FFX-CJYL-FFX-C
NameOverhead On the Spot(transient)Overhead On the Spot(External Signal)Overhead Long Distance(transient)Overhead Long Distance(External Signal)Overhead Long Distance(Transient Recording)
Basic Function
Short Circuit fault indicator
Ground fault indicator
Local fault alarm
Remote fault alarm––––
Fault status reset
Transient fault blocking alarm
Low battery alarm––––
Self-checking––––
Automatic monitoring of load fluctuation
Automatic suppression of inrush current
Electric installation and disassemble
Minimum reclosing time
Heartbeat function––––
Remote upgrade and maintenance––––
Advancde Function
Electrical monitoring––––√*√*
Online recording function ––––––––
Clock synchronization––––
Remarks: Optional Function 

 

Collect Unit Featuress

Product JYW-FFD-H/JYZ-FFD-HJYZ-FFD-H
NameCollection Unit(Transient Characteristics External Signals)Collection Unit(Transient Recording)
Basi Function
Short-circuit & ground fault
Time upgrade load current 
Low battery alarm
Fault indicator status monitoring
Heartbeat function
Response master message
Remote modify parameters
Clock synchronization
Historical data storage
Local and remote maintenance
Protocal parameter configuration
Advanced function
Remote signal data acquisition√*√*
GPS time synchronization√*√*
Phase time synchroization––
Zero sequence current synthesis––
Zero sequence voltage synthesis––

 

No desirable products?
Sourcing assistant>
How to start your business
  • Step 1
    Find your interested products by search keywords
  • Step 2
    Contact the supplier by clicking ”Enquire” or “request meeting” button, otherwise, you also could consult our import consultant.
  • Step 3
    After verifying your email, get response from suppliers or our trade manager will contact you as soon as possible
  • Step 4
    Set up meeting with the Chinese supplier without language barrier
Send Enquiry
ToLily Liu
Meorient Import & Export Co.LTD
Enquire
Popular Searches
lathersbuchertether.thermosatherosfortherusherfinetherhb thermfortherthoraether.thermoslocherfletcher