Ⅰ. Products of Escalator Brief Introduction
SAFE escalator adopts advanced drive system, fault self diagnosis and display device technology, automatic lubrication system and special frequency conversion technology. Our products can meet European standards and Chinese standards, it is designed and manufactured with new materials and advanced technology. The diversified design style is integrated with the building, reflecting the noble and elegant comfort. Safe commercial escalator is suitable for culturaland sports, commercial center, logistics center, hotel club, medical care and other construction sites.
Ⅱ. Superior performance of escalator
● The truss utilizes first class rectangle steel with unique structure, high strength and nice anti-corruption durable features
● The overall design is concise and smooth and compatible
● The advanced international craftsmanship ensures the accuracy of steps
● The large size dimeter of step roller operates minimizes the noise and extend the product life
● The human-oriented handrail entrance is secured by brush
● The skirt together with interior and outside deck uses dulex stainless steel
● Stamping stainless steel front panels are available with various varieties It adopts belt braking system controlled by braking motor
which brake smoothly and reliable
● The super CPU main board monitors the operation in real time. if any abnormal situation occurs. it automatically brakes and records the malfunctions code
● Customer can choose VVVF drive to control running speed, the energy saving performance is obvious. It can prolong product life and reduce the operation cost
Ⅲ. Two Types of Standard Construction Layout Drawing of Escalator (35° & 30 °)
Ⅳ. The Functions Details of Escalator
Standard Functions
● Skirt panel brush
The skirt board brushes . mounted on both sides of the skirt boards and located above the steps , can not only avoid the passengers , shoes to collide on the skirt boards but also effectively avoid the entry of foreign objects into the steps.
● Handrail inlet
The escalator is richly endowed with the intelligence and popularity by the novel , distinctive , elegant , tensile and modernized streamline handrail inlet and outlet design model . It appears to be more beautiful in the outer appearance . It displays the nobleness and imposing manner of the conveying constructions.
● Automatic oiling
PLC control automatic oiling and lubricating system fulfills the idea automatic lubrication to the transmission chain during the running process of the escalator . It not only reduces the daily repair and maintenance word load , but also prolongs the service life of the driving mechanism.
● Side guide high accuracy step guide rail system
High rigidity big profile guide rail with nose used as transverse step positioning guarantee the minimum gap between the skirt and step, decrease the possibility of objects clamp in between.
● Driver protection strand breaks
When the drive chain excessive tensile fracture , the escalator stops automatically to protect the safety.
● Fault display
When some defect takes place , the trouble code will be displayed in the defect screen , it ensures the effective and accurate trouble position within the shortest time possible. In this way , It greatly enhances the repair and maintenance efficiency.
● Handrail speed
When handrail running speed and running speed ratio exceeds cascade system settings , escalators stopped running.
● Handrail Color: Black (Standard)
● The glass wainscot color: Colorless and transparent (Standard)
● Balustrade height:1000mm is standard specification
Optional Functions
● Comb lighting
Lighting was installed near the apron panel beside the comb plate , to provide lighting for the steps and the comb plate to facilitate passengers safe ride.
● Skirt-board Lighting
Two sides LED lighting lamp, with the clear effect on the evening of step running.
● Running direction indication
The running direction and forbidden display mark have been placed in the intel and outlet of the handrail . The obvious running or forbidden instruction ensures the safe riding of the passengers with great ease.
● Heating device
Each escalator usually installs three heating devices , One is beside the host in the upper machine room . It mainly heats the host The second is installed in the mid escalator And the third is in the lower part . It mainly heats the whole escalator.
● Voice man machine interface system
It will be installed in the entrance. When the passengers pass , the voice prompts to take precautions.
Ⅴ. Standard Safety Device
Standard Safety Device
1. Lack of phase, error phase protection
If lack of phase or error phase has been checked out, the escalator (moving-walk) will automatically stop the operation.
2. Motor over-load protection
When the current exceeds 15% of the current rating, the escalator will automatically stop the operation.
3. Electrical appliance loop protection
If offfers the automatic circuit disconnecting device to protect the circuit the and mains components of the escalator(moving-walk)
4. handrail inlet protection
When some foreign substance has been clipped in the handrail inlet, escalator (moving-walk)will automatically stop the operation.
5.comb plate safety device panel
When some foreign substance has been clipped in or between the combs, the escalator (moving-walk) will automatically stop the operation.
6. Step sagging protection device
When there is abnormal step bending, the escalator)moving-walk) will stop the operation before the step entering into the comb plate.
7. Broken drive-chain safety device
When the drive-chain has been over-stretched or it is broken, the escalator (moving-walk) will automatically stop the operation.
8. Broken step chain protection
When the step (plate) chain has been over-stretched or it is broken, the escalator(moving walk) will automatically stop the operation.
9. Over-speed protection
When there is over-speed to the escalator (moving walk), it will automatically stop the operation.
10.Dirction reversal protection
When it comes the unintentional reversal of the direction of travel, the escalator (moving walk) will automatically stop the operation.
11.Security line
The yellow synthetic resin security line is located in the front position and two sides of the escalator tread so that the passengers will not tread in-between the edge of the adjacent step and the lift group lengthened skirt panel. The security line on both sides of the step is higher than the tread surface. (The moving-walk offers the selective yellow spray-painted security line)
12. Emergency stop button
When the button has been pressed down, the escalator (moving-walk) will stop the operation.
13 .Skirt panel protection
When some foreign substance has been clipped in between the skirt panel and the step , the escalator ( moving-walk will automatically stop theoperation
14 . Brake protection
When the electric force falls short of supply or it acts any of the safety levice , the brake function goes into effect by the safety device through the spring resilience action , in this way , the escalator ( moving-walk ) stop the operation
15 . Safety inspection switch
It is a safety device to prevent from the escalator starting during the inspection and maintenance
16 . Step illumination
Illumination exists in the upper and lower ends of the escalator , in the lower part of the step in order to remind the passengers of the security matters
17 .Alarm bell starting device
The alarm bell rings when it starts the escalator in order to remind the passengers of the security matters
18. Control device for handrail breakage
When the handrail is broken , the escalator will automatically stop the
19. Handrail speed monitor
When the handrail speed versus step is slower than certain percentage the escalator(moving-walk )will stop the operation
20. Skirt panel brush
It is a selective safety device. The brush that has been installed between the skirt panel and the step will prevent the passengers from touching the kirt panel, (it is not merely restricted to the escalator.)
21.Double independent control systems
It brings about the safer and the more stable escalator travel
22. Step loss detection device
Safety device to protect the passengers
23. Tread swart switch
When it opens the tread and maintains the escalator, the escalator stops and is under security condition
24. Detection of brake distance
If braking distance is 1.2 times longer than stipulation of national standard, after trouble locking and reset, it starts again. If necessary, please check breaking system before manual reset and apply correction measures
25. Brake release detection Brake
adding detection switch prevents from the motor running without brake release so that it avoids burning the host or fire disaster.
Optional Safety Device