sphygmomanomet arm blood pressure
Features:
Easy to operate | Measure the wrist joint ,Smart pressurization |
HD English voice broadcast | Built-in lithium battery, can be used multiple times when fully charged |
USB cycle charging, no pollution, environmental protection and fast, trustworthy | Over pressure protection |
WHO blood pressure health status warning strip | Arrhythmia prompt function |
90 sets of data memory function for two people | Query the memory data in sequence |
LCD HD display | The operation is automatically turned off for 1 minute without operation |
Accuracy: blood pressure ± 3% heart rate ± 5% | Measuring range: blood pressure 0 ~ 280mmHg pulse 40 ~ 199 times / minute |
the elbow may lead to errors in blood pressure measurement.
The cuff pipe should not be suspended and should be placed securely.
Body movement and limb activity during measurement can seriously affect the accuracy and repeatability of blood pressure readings.
This is because the oscillometric electronic sphygmomanometer relies on very weak changes in cuff pressure. Any disturbance can affect the collection of the signal. In addition to active hand movements, passive movements such as ambulance vibrations and bed movement may also affect the accuracy of blood pressure readings.
The accuracy of oscillometric electronic sphygmomanometers in measuring blood pressure is questionable when the pulse is weak, such as in patients in shock, hypovolemia, and peripheral vascular disease. In addition, the oscillometric electronic sphygmomanometer encounters challenges in the measurement of blood pressure in newborns, which requires a special design to address such problems.
Ambient noise such as ambulance movement signals can sometimes be greater than the physiological pulse signal to be detected, resulting in measurement errors. Fortunately, current oscillometric electronic sphygmomanometers are equipped with sound insulation settings that can reduce the interference of ambient noise to some extent.
Although existing oscillometric electronic sphygmomanometers are designed with some degree of heart rate variability in mind, the more severe heart rate variability can significantly affect the accuracy of oscillometric electronic sphygmomanometer blood pressure measurements. The most obvious example of this is atrial fibrillation.
Diabetes mellitus, renal failure, pre-eclampsia, peripheral vascular disease, etc.
The accuracy of the oscillometric electronic sphygmomanometer may also be affected to some extent due to variations in vascular performance. To further address such issues, system procedures need to be optimized for a more reliable calculation method based on a large number of patient measurements.
Some poor quality oscillometric electronic blood pressure monitors are also relatively inaccurate and less stable due to the quality of their components and the lack of certification of their system procedures for bulk data. Blood pressure measurements may be inaccurate when the battery is close to depletion and the voltage is low.
Only those oscillometric electronic blood pressure monitors that have been validated to international standards should be used in clinical and home use.
1,In a quiet, relaxed, natural environment, the subject was seated upright with the feet flat against the floor
2. Remove all clothing at the wrist so that the wristband can be wrapped directly around bare skin.
3. Ask the patient to hold the hand straight out with the palm up. At 1 cm from the palm of the hand, put the sphygmomanometer on the patient's wrist with the display upward and fasten the wrist strap as tightly as the patient feels comfortable.
4. Bend your forearm upward and place it close to your chest so that your wristband is flush with your heart, and lightly rest your left elbow with your right hand.
5,Press the start button, and when it is automatically inflated and completely deflated, you can read the blood pressure data directly from the display and record the data.
dinamap blood pressure monitor
Responsibility Honesty Professional Innovation Win-win
YouWeMed CO., LTD. specializes in the development and design of medical devices, with a particular focus on the medical phototherapy. It is a high-quality supplier of phototherapy manufacturing solutions. YouWeMed Co., Ltd. consistently timely delivery of quality products for our customers and excellence in service. All of our products have CFDA and Medical CE, ISO13485.
Q1: How is the quality of your products?
Q2. Can I order samples of this product? Answer: Yes, we welcome to order samples to test and check the quality. Mixed samples are acceptable.
Q3: How long is the delivery time? Answer: Quantity (unit) 1-100 units, shipped within 7 days. Mass production of more than 1,000 orders requires 2 weeks of production time.
Q4. Do you have a minimum order quantity limit for product orders? Answer: The minimum order quantity can provide 1 sample for inspection.
Q5. How do you ship the goods and how long will it take to arrive? Answer: First of all, you can choose sea or air transportation. Air transportation is usually delivered by DHL, UPS, FedEx or TNT. The specific time will appear directly when you purchase the goods.
Q6: What is the warranty period? |