Features
Technical data
Parameter
Parameter | Functions | Set range | Default |
E1 | lower set point | -45C~set range | 00C |
E2 | higher set point | set range~50C | 12C |
E3 | temp.hysteresis | 01~20C | 04C |
E4 | comp.start delay time | 0~10min | 2min |
E5 | offset on room temp. | -10~10C | 00C |
F1 | max defrost duration | 01~60min | 15min |
F2 | defrost interval time | 00~24hr | 03hr |
F4 | display durning defrost | 00=normal display 01=last value before defrost | 01 |
C2 | high temperature alarm | C3~50C | 40C |
C3 | low temperature alarm | -45C~C2 | -40 |
C4 | alarm time delay | 01~90~01min | 60min |
H1 | fan control | H1=01 parallel with comp.except defrost H1=02 parallel with comp. H1=03 continuous running H1=04 continuouos running except defrost | 03 |
H2 | fan control delay time | 00~240s | 00s |