The main chip of LORAWAN communication module adopts the high-performance embedded ARM cortex-m3 32-bit RISC controller, which
ensures the stability of the device with multilevel software detection and multiple hardware protection mechanisms.It is composed
of the powerful ARM cortex-m3 32-bit RISC microcontroller and Lorawan wireless spread spectrum chip .
(2)Product features:
1. measurement function
* real-time pulse counter accumulates flow
* strong magnetic detection trigger alarming info.
2. historical data store locally
* the data during latest 90 days store every one hour
* the data during the latest 180 days stores everyday
* the data during the latest 1 year stores every month
3. Power supply: one main battery for supplying daily , another one for spare battery
4. Main battery capacity level indicator
* In each measurement data consumption on the road up the service reported to the battery capacity level suffixü
* Low battery threshold :when the battery capacity is less than 20%, it will trigger low battery alarm and the low battery
alarming info.will be reported every 24 hours untill spare battery switch threshold
* Battery switch threshold : capacity of 10% will trigger the switch of spare battery
5. Spare battery switch only in the following cases; otherwise, use the main battery.
* Pull out the battery or the battery does not exist
* the main battery theshold is 10%
* The switch of spare battery is automatic so that i will not be outage
6. Spare battery function
* Water flow control partial measurement
* historical data storage
* spare battery exceeds 7 days at least
* When spare battery is used , the alarming info. Of spare battery will be reported to server
7. The spare battery protection in transportation
* Prior to on-site activation, the meter is equipped with only spare batteries, and in the warehouse or during transportation,
protection will be provided to prevent the consumption of the spare batteries.
8. Battery life: 6
9. operating temp.:-5~+ 85℃
10. LED indicator: indicates LORA event
11. Manual triggering lorawan uplink for testing
12. Wireless technology: lorawan in EU868
13. LoRaWAN class: class A
14. LoRaWAN reports regularly measured data for a period of 24 hours by default
The message payload includes
* the latest accumulated measured data
* statue of meter: valve,power, strong magnetic detection
* battery capacity
* lorawan downlink signal indicator RSSI/SNR
15. LoRaWAN fixed time metering data report (ON/OFFconfigurable).LoRaWAN metering data report is triggered every day at fixed time
(e.g. 23:00, configurable), and the message payload is the same as the periodic report
* the latest accumulated measured data
* statue of meter: valve,power, strong magnetic detection
* battery capacity
* lorawan downlink signal indicator RSSI/SNR
16. LoRaWAN alarming info. Uplink report
* low battery alarm
* spare battery switch alarm
* valve error alarm
* strong magnetic detection alarm
17. LoRaWAN downlink set/inquire
* Set up/query LoRaWAN periodic metering data report cycle
* Fixed time measurement data report/switch/set up/inquiry/time
* Modify accumulated water flow data for calibration
* read the data of current accumulated water flow
* battery capacity reading
* valve control switch