Enquiries
Message
Home > Products > Other
animal doppler blood pressure meter ultrasonic veterinary doppler blood moniotring equipment animal doopler blood pressure kit
  • animal doppler blood pressure meter ultrasonic veterinary doppler blood moniotring equipment animal doopler blood pressure kit

animal doppler blood pressure meter ultrasonic veterinary doppler blood moniotring equipment animal doopler blood pressure kit

FOB Reference Price
Purchase quantity ()
Minimum order quantity
Payment
Meorient Import & Export  Co.LTD
Meorient Import & Export Co.LTD
China - Hangzhou
Trading Company
Trade Capacity
Export Percentage
Nearest Port
Hangzhou,Shanghai
Accepted Delivery Terms
Employees
5-10人
Accepted Payment Currency
USD,CNY
Average Lead Time
45 Day(s)
Certifications
Product Specifications
--
Product Description
Overview
Quick Details
Place of Origin:
Anhui, China
Brand Name:
JNR
Model Number:
DS-200
Instrument classification:
Class I
Type:
Blood Pressure Monitor
cuff:
5 size
Packaging & Delivery

 Veterinary doppler blood pressure machine 

 

JNR COMPANY 

Hefei Golden Brains Optical Instrument Co.,Ltd.

 

 

 

 

 

 

 

 

 

Doppler machine, ultrasonic principle.

 

 

Technical Parameters:

 

1. Measuring range:0mGs~199.9mGs

 

2. Frequency of the probe: 8MHz

 

3. Specification of the blood pressure cuff

 

Range: No.1 4.2cm-7.1cm

 

No.2 5.4cm-9.1cm

 

No.3 6.9cm-11.7cm

 

No.4 9.0cm-13.0cm

 

No.5 12.0cm-16.cm

 

No.6 17.0cm-22.0cm

 

4. Rechargeable battery voltage: 7.4V, 1500mAh

 

5. AC Input: 100-240V 50/60Hz DC Output DC8.4v, 1000mA

 

6. Continuous working time : > 8 hours

 

7. Speaker: 4Ω, 1W

 

 

 

 

 

 

PACKAGE DETAIL:

 

1.the Doppler Blood Pressure Meter 

2. the valve on the blood pressure meter which is used to control inflating and deflating

3. gasbag on the blood pressure meter which is used for inflating and deflating

4.the high-sensitive probe 

5. different sizes of cuffs

6. charger of for the main machine 

7. earphone 

8. medical ultrasonic couplant

9. the aluminum box which is used to contain all of the parts and for carrying

 

 

 

The main machine of the Doppler blood pressure meter

 

 

 

The 1. on the main machine is the on and off switch also it can be used to control the volume of the sound   The 2. on the main machine is a power indicator light.(which indicate whether it is connected with the charger) 3. hole for earphone 4.Speaker 5. connector for the high sensitive probe  6. hole for the charger 

 

 

 

 

 

 

OPERATION DETAIL:

 

 

Note:

 

1.Cutting off fur on volar pad especially fur beneath the first toe and the cleaner, the better. And then smear couplant on the midline of the foot.

 

2.Smearing much couplant on probe and put the probe on the midline. Then you can hear sound like “so -so -so”.If not ,please remove the probe till the sound can be heard .

 

3.When pets in examination in the section of outpatient ,they are always in tension .At this time ,It is advice to do the examination with 3 medical staffs :one person is to keep pets quiet , one is to use the probe to find pets pulse and the third person is to inflate and deflate the pressure meter .

 

When monitoring pets in operation, there is needing only one person to do blood pressure meter every 5-10 minutes.

 

4.Cuff should be placed above the pet forelimb wrist (proximal to the heart ).The indicatrix on the end of cuff should be in the range of the circumference. If not,the tested blood pressure will be much higher (the cuff is large compared with the limb ) or much lower ( the cuff is small  compared with the limb )   

 

5.Close the walve and begin the inflation. When you do not hear the sound like “so-so-so”,continue to inflate 20mmHg more and then open the walve and begin to record the systolic pressure .

 

6.When in slow and continuous deflation, diastolic pressure can be recorded .However ,diastolic pressure is easily affected by many factors such as probe’s position ,degree of tightness and so on so that it is not easy to hear the sound of the diastolic pressure . And this is due to the Doppler theory. But a experienced doctor with many times practice may can test the diastolic pressure .

 

7. It is advice to do the examination in room with heating installation in winter because room temperature is below 10°C or pets’skin temperature is too low , the examination will be influenced and it is not easy to hear the sound of “so -so -so”. I f pets are too small or their vessels are narrow ,it is usual that blood flow can not be heard .

 

8.The usual blood pressure range for cats and dogs is from 110mmHg to 160mmHg .

 

 

 

 

 

 

No desirable products?
Sourcing assistant>
How to start your business
  • Step 1
    Find your interested products by search keywords
  • Step 2
    Contact the supplier by clicking ”Enquire” or “request meeting” button, otherwise, you also could consult our import consultant.
  • Step 3
    After verifying your email, get response from suppliers or our trade manager will contact you as soon as possible
  • Step 4
    Set up meeting with the Chinese supplier without language barrier
Send Enquiry
ToLily Liu
Meorient Import & Export Co.LTD
Enquire
Popular Searches
lathersbuchertether.thermosatherosfortherusherfinetherhb thermfortherthoraether.thermoslocherfletcher