YJV YJV22 YJV32 Copper XLPE/PVC/SWA Power Cable 3x16+1x10 mm2
1.Standard:
Chinese standard (GB) and international standard (IEC),
ISO 9001:2008
CCC certificate
Apply for indoor, underground and conduit
2.General Characteristics:
1) The long time working temperature of cable should not be higher than 70°C .
2) When core is in short circuit(max5s) the temperature should not exceed 160°C.
3) While installation the ambient temperature should not be lower than 0°C,and
the bending radius should not be less than 10 times of outer diameter of cable.
4) Perfect chemical stability, resistant against acids, alkalis, grease and organic solvents, and flame retardance.
5) Light weight, perfect bending properties, installed and maintained easily and conveniently.
6) Voltage rating: 0.6/1KV, 3.6/6KV
3. Technical Requirements:
XLPE Insulated PVC Sheathed Power Cables
Standards: IEC60502, GB/T12706-2002
4.Application:
It is suitable to be installed indoors, in duct, tray or direct burial, with rated low voltage of U0/U (0.6/1KV) and medium voltage of U0/U (6/6KV; 6/10 KV; 8.7/10 KV; 8.7/15 KV; 26/35 KV; 26/45KV) for transmitting electricity.
XLPE insulated power cable has a number of advantages over PVC insulated cable. XLPE cable has high electric strength, mechanical strength, high-ageing resisting, environmetal stress resisting, antichemical corrossion. It can be laid with no drop restriction.
Rated voltage(KV) |
3.6/6 |
6/6 |
6/10 |
8.7/10 |
8.7/15 |
12/15 |
12/20 |
18/20 |
18/30 |
21/35 |
26/35 |
|
Core Number |
1 core, 3 core |
|||||||||||
Cross-section mm2 |
1C |
25~800 |
35~800 |
|||||||||
3C |
25~400 |
35~400 |
Type | Discription | Rated Voltage (KV) | Number of cores | Nominal Cross-sectional Area (mm2) | |
Cu | Al | ||||
YJV YJLV |
YJV: Copper conductor XLPE insulated and PVC sheathed power cables. YJLV: Aluminium conductor XLPE insulated and PVC sheathed power cables. |
0.6/1KV | 1 | 1.5~1200 | 4~1200 |
2 | 1.5~300 | 4~300 | |||
3 | 1.5~300 | 4~300 | |||
4 | 1.5~300 | 4~300 | |||
5 | 1.5~300 | 4~300 | |||
3+1 | 1.5~300 | 4~300 | |||
3+2 | 1.5~300 | 4~300 | |||
4+1 | 1.5~300 | 4~300 | |||
Media voltage power cable | 6/6; 6/10; 8.7/10; 8.7/15; 26/35; 26/45 | 1 | 25~630 | 35~630 | |
3 | 25~400 | 35~400 | |||
YJV22 YJLV22 |
YJV22: Copper conductor XLPE insulated and PVC sheathed steel tap armoured power cables. YJLV22: Aluminium conductor XLPE insulated and PVC sheathed steel tap armoured power cables. | 0.6/1KV | 1 | 10~500 | 10~500 |
2 | 2.5~300 | 4~300 | |||
3 | 2.5~300 | 4~300 | |||
4 | 2.5~300 | 4~300 | |||
5 | 2.5~300 | 4~300 | |||
3+1 | 2.5~300 | 4~300 | |||
3+2 | 2.5~300 | 4~300 | |||
4+1 | 2.5~300 | 4~300 | |||
High voltage power cable | 6/6; 6/10; 8.7/10; 8.7/15; 26/35; 26/45 | 1 | 25~630 | 35~630 | |
3 | 25~300 | 35~300 | |||
YJV32 YJLV32 |
YJV32: Copper conductor XLPE insulated and PVC sheathed steel wire armoured power cables. YJLV32: Aluminium conductor XLPE insulated and PVC sheathed steel wire armoured power cables. | 0.6/1KV | 1 | 50~500 | 50~500 |
2 | 35~300 | 50~185 | |||
3 | 25~300 | 35~300 | |||
4 | 25~300 | 35~300 | |||
5 | 25~240 | 35~240 | |||
3+1 | 25~300 | 35~300 | |||
3+2 | 25~300 | 35~300 | |||
4+1 | 25~240 | 35~240 | |||
Media voltage power cable | 6/6; 6/10; 8.7/10; 8.7/15; 26/35; 26/45 | 1 | 50~630 | 50~630 | |
3 | 25~300 | 35~300 |