1. 100% unbalance loads design.
2. Low frequency, pure sine wave output.
3. Wide AC voltage input range, AVR output.
4. Peak power more than 3 times.
5. LCD display for all working datas.
6. AC prior/EC mode/Battery prior selectable.
7. AC charge current 0~45A selectable.
8. Seven battery type selectable, RS232/RS485/APP/SNMP/GSM communication port optional.
Specification | |||||||
Model HDSX | 30248 | 30296 | 302192 | 50248 | 50296 | 502192 | |
Rated Power | 3KW | 3KW | 3KW | 5KW | 5KW | 5KW | |
N.W.(kg) | 58 | 58 | 58 | 73 | 73 | 73 | |
G.W.(kg) | 71 | 71 | 71 | 86 | 86 | 86 | |
Battery Voltage | 48VDC | 96VDC | 192VDC | 48VDC | 96VDC | 192VDC | |
Size(L*W*Hmm) | 565*300*775 | ||||||
Packing Size(L*W*Hmm) | 625*360*895 | ||||||
Parameter | |||||||
Input | Battery Input Voltage Range | 42V~60V for 48V system; 84V~120V for 96V system; 168V~240V for 192V system | |||||
AC Input Voltage Range | 380Vac/400Vac±10%(customized 190Vac/200Vac) | ||||||
AC Input Frequency Range | 45Hz-65Hz | ||||||
Phase | 3/N/PE | ||||||
Output | Efficiency(Battery Mode) | ≥85% | |||||
Output Voltage(Battery Mode) | 380Vac/400Vac±10%(customized 190Vac/200Vac) | ||||||
Output Frequency(Battery Mode) | 50/60Hz ±1% | ||||||
Output Wave(Battery Mode) | Pure Sine Wave | ||||||
Output waveform distortion | Linear load≤3% | ||||||
Efficiency(AC Mode) | >99% | ||||||
Output Voltage(AC Mode) | Conforming to AC input | ||||||
Output Frequency(AC Mode) | Conforming to AC input | ||||||
Phase | 3/N/PE | ||||||
AC charger | AC charging current | 0~45A selectable | |||||
AC charging method | Three-stage(constant current, constant voltage, floating charge) | ||||||
Battery type (Optional) |
U0: Gel U.S.A | Charge Voltage: 56V for 48V system, 112V for 96V system, 224V for 192V system; Float Voltage: 54.8V for 48V system, 109.6V for 96V system, 219.2V for 192V system. |
|||||
U1: A.G.M.1 | Charge Voltage: 56.4V for 48V system, 112.8V for 96V system, 225.6V for 192V system; Float Voltage: 53.6V for 48V system, 107.2V for 96V system, 214.4V for 192V system. |
||||||
U2: A.G.M.2 | Charge Voltage: 58.4V for 48V system, 116.8V for 96V system, 233.6V for 192V system; Float Voltage: 54.8V for 48V system, 109.6V for 96V system, 219.2V for 192V system. |
||||||
U3: Sealed lead Acid | Charge Voltage: 57.6V for 48V system, 115.2V for 96V system, 230.4V for 192V system; Float Voltage: 54.4V for 48V system, 108.8V for 96V system, 217.6V for 192V system. |
||||||
U4: Gel European | Charge Voltage: 57.6V for 48V system, 115.2V for 96V system, 230.4V for 192V system; Float Voltage: 55.2V for 48V system, 110.4V for 96V system, 220.8V for 192V system. |
||||||
U5: Open lead Acid | Charge Voltage: 59.2V for 48V system, 118.4V for 96V system, 236.8V for 192V system; Float Voltage: 54V for 48V system, 108V for 96V system, 216V for 192V system. |
||||||
U6: Calcuim(open) | Charge Voltage: 60.4V for 48V system, 120.8V for 96V system, 241.6V for 192V system; Float Voltage: 54.4V for 48V system, 108.8V for 96V system, 217.6V for 192V system. |
||||||
U7: Sulphation cycle | 15.5V for 4hrs | ||||||
customize battery | Charge and discharge parameters of different types of batteries (such as lithium batteries, etc.) can be customized according to user requirements. | ||||||
Working Mode(Selectable) | AC prior(d1) | Under AC prior mode, device will always use utility source and through regulator to supply loads as well as charge battery(charging current selectable); when utility power is with high/low/serious distortion or other abnormal, device will auto converter battery source to supply loads. | |||||
EC mode(d2) | Under Energy saving mode, device dedects load, when the load is <10% rated power, device will auto on/off AC output; when the load is > 10% rated power, device will start AC output. | ||||||
Battery prior(d3) | Under Battery prior mode, device will always use battery source to coverter high quality electricity for load; when battery source is failed, device will auto use utility source and through regulator to supply loads. | ||||||
Protection | Battery low voltage alarm | 44V for 48V system, 88V for 96V system, 176V for 192V system | |||||
Battery low voltage protection | 42V for 48V system, 84V for 96V system, 168V for 192V system | ||||||
Battery high voltage alarm | 60V for 48V system, 120V for 96V system, 240V for 192V system | ||||||
Battery high voltage protection | 68V for 48V system, 136V for 96V system, 272V for 192V system | ||||||
Battery high voltage recover | 58V for 48V system, 116V for 96V system, 232V for 192V system | ||||||
Overload protection | Automatic protection (battery mode), circuit breaker or insurance (AC mode) | ||||||
Inverter output short circuit protection | Automatic protection (battery mode), circuit breaker or insurance (AC mode) | ||||||
Temperature protection | >90°C(Shut down output) | ||||||
Alarm | A | Normal working condition, buzzer has no alarm sound | |||||
B | Buzzer sounds 4 times per second when battery failure, voltage abnormality, overload protection | ||||||
C | When the machine is turned on for the first time, the buzzer will prompt 5 when the machine is normal | ||||||
Transfer Time | ≤4ms | ||||||
Display | LCD | ||||||
Thermal method | Cooling fan in intelligent control | ||||||
Communication | RS232/RS485/APP/SNMP/GSM(Optional) | ||||||
Environment | Operating temperature | -10℃~40℃ | |||||
Storage temperature | -15℃~60℃ | ||||||
Noise | 2000m(More than derating) | ||||||
Elevation | ≤65dB | ||||||
Humidity | 0%~95% ,No condensation | ||||||
Note: All specifications are subject to change without prior notice |
1. Battery number and capacity should be configured according to the rated voltage of the solar power system or invertor;
2. We offer 3 optional working modes (transfer time≤4ms):
01 Grid priority mode: When the grid and battery are connected to the invertor, grid will supply power to the loads directly after voltage being stabilized and charge batteries via invertor. When the grid is cut off, the battery will automatically continue to supply power via invertor.
02 Energy saving mode: If the power of the connected AC loads is lower than 5% of the invertor’s rated power, there will be no output from the invertor. Only the chip of invertor is working. The power consumption of the invertor is only 1~6W. The LCD shows the output voltage 0. If the power of the connected loads is over 5%, within 5S the invertor will automatically convert DC to AC to supply power for the loads . The LCD shows the output voltage.
03 Battery priority mode: When the grid and battery are connected to the invertor, battery will supply power to the loads first. When battery capacity is not enough, the grid will continue to supply power automatically.
Package
Carton Box for packaging, or Wooden Box advised for Samples to protect in transportations.
Shipping
1. Fedex/ DHL/ TNT/ UPS for samples, door-to-door.
2. By air or by sea for batch goods, for CFL, Air port/ Port receiving.
3. Customers specifying freight forwarders or negotiable shipping methords.
4. Delivery time: 7 days for samples; 10 to 25 days for batch goods.
Payment | ||
T/T | EXW | 30% T/T in advance, balance paid before dispatch |
FOB | ||
CNF(CFR) | 30% T/T in advance, balance paid against copy of B/L | |
CIF | ||
L/C, D/A, D/P, Money Gram, Western Union, Paypal (Optional) |
Guangdong Xindun Power Technology Co.,Ltd | |
Factory Location |
Foshan,Guangdong,China |
Industry Experience |
13-year manufacturer, 16-year trading, 8-year alibaba gold supplier |
Product Range |
solar inverter, hybrid inverter, ups, solar charge controller, solar power system, mini solar dc system |
Main Market | Africa, Middle East, Asia & South America. (Ukraine, Russia, Vietnam, Pakistan, Nigeria, Kenya, South Afriac, Ghana, Thailand, Philippines, etc.) |
Factory | 6000 Square Meters, 60+ workers |
Department | R&D, Production, Sales, Marketing, Purchasing, QA, After-sale service department |
Certificate | ISO9001:2015, CE, IEC, etc. |
Patent | Software Paten, Design Patent, Project Pantent |
Q1: Are you a factory?
A: Yes, we are ISO9001:2015 manufacturing with qualifications of TUV, CE, ROHS & CCC. main products including inverter, solar controller and solar energy system solution.
Q2: Are you inverter pure sine wave output?
A: Yes, all of our inverter are pure sine wave output.
Q3: What kind of output you can do?
A: Normally, we produce inverter with 110v/ 50Hz, 120V/ 60Hz, 220v/ 50Hz, 230v/ 50Hz, 240V/50Hz.
If you have special requirements, pls tell us for engineer consulting.
Q4: What appliances your inverters can load?
A4: Our inverter can load household appliances other inductive load such as refrigerator, air condition, water pump, etc.
Q5: How long is your factory?
It's over 10 years. at the beginning our factory focused on domestic market.
From 2012, we set up our oversea sales department.
Q6: What' s the difference between low frequency and high frequency inverter?
A: Low frequency inverter has various protections, strong ability to adapt to the environment. more reliable, with voltage regulation.
Q7: What's the difference between pure sine wave inverter and modified sine wave inverter?
A: Pure sine wave output inverter is just as good as the Public power grid. Even better. Low repaired rate, long lifespan, Without harmonic pollution, enviromental-friendly and appliances protected.
Modified sine wave output has a negative impact on appliances and can't load inductive load, such as air contition, refrigerator and etc. Certain motor control circuits don't like the modified wave.
Q8: How to solve the technical problem?
A: 24 hours after-service consultancy just for you and to make your problem to solveeasily.
Q9: What to do if the product is broken?
A: Usually we do standard exporting package and insurance in case of broken. If any product is faulty, please send us the picture or video, we will study it and supply the spare parts of PCB board free for after sale service.