Specification:
1. Environment Temperature:0~50°C,RH<95%
2.Relay contact: 5A/240VAC
3.Power Supply:Fit for all parts of the worlds
4.Display:4 LED display
5.Measuring Range: 0.00~14PH
6.Resolution: 0.01PH
7.Accuracy: ±0.1%+2Digital
8.Setting Range: 3.50~10.50PH
9.Calibration:double points
10.Power Consumption:2 watts
Remark(Instruction for Cleaning And Maintenance)
1)There is a protection "dead band" for output ot action. The control output in action when the PH measuring value goes above the set value 3~5 digitals.The control output off when the PH measuring value below the set value 3-5 digitals.(when slide HI/LO switch in "HI" position.)
2) The Control output will be automatic turned off when slide the {PH/SET} function switch in "SET" position while adjusting the set value.
3)It must to pull out the power plug( turn off) when cleaning the controller.
4)Please wipe the housing with drying when cleaning, do not wipe with wetting.
5)It had better cleaning the PH electrode sensor with soft brush and calibrate the PH electrode during 2-3 weeks to make sure the reading within accuracy when mwasuring in a long time.
6)In door use only.
Note: Please use this controller away from electronic ballast.