XGN15-12/24 Fixed Type Metal-clad Switchgear Break Switch
XGN15-12/24 series of unit-type metal-enclosed switchgear takes FLNO-12/24 type SF6 load break switch as the main switch, and the entire cabinet is air-insulated, suitable for distribution automatic, compact and expandable metal-enclosed loop network switchgear. It has features of simple structure, flexible operation, reliable interlocking, easy installation and so on. It can provide satisfactory technical solutions for a variety of different applications and different user requirements which comply to IEC 62271.
XGN15-12/24 series of unit-type metal-enclosed switchgear takes FLN36-12/24 or produced by our company or SFG SF6-type load switch produced by ABB company as the main switch, it can also equip VS1 type, VD4/S type, ISM type vacuum circuit breaker or HD4/S5 SF6 circuit breaker according to the needs of users. Load break switch and circuit breaker can be manually or electrically operated, and can achieve power distribution automation when being equipped with optional electric operating mechanism, PT, CT, FTU and communication devices.
MODEL AND MEANING
Technical Sheet
Rated Voltage |
kV |
12 |
24 |
||
Rated lightning impulse withstand voltage |
Phase to phase, phase to earth |
kV |
75 |
125 |
|
Across open contacts |
kV |
85 |
145 |
||
1 min P.F. withstand voltage |
Phase to phase, phase to earth |
kV |
42 |
65 |
|
Across open contacts |
kV |
48 |
79 |
||
Rated frequency |
Hz |
50 |
50 |
||
Rated current |
Main bus-bar |
A |
630 |
630 |
|
Branch line |
A |
630 |
630 |
||
Rated short circuit withstand current |
LBS |
kA |
20 |
20 |
|
ES |
kA |
20 |
17.4 |
||
Rated duration of short-circuit withstand current |
S |
4* |
4 |
||
Rated peak withstand current |
kA |
50** |
50 |
||
Transfer current |
A |
1700 |
1200 |
||
Protection degree |
—— |
IP3X |
>IP3X |
||
Load break switch mechanical life |
time |
>5000 |
>5000 |
||
Earthing switch mechanical life |
time |
>2000 |
2000 |
||
Load switchgear |
Width |
mm |
375,500,750 |
600 |
|
Depth |
mm |
1000 |
1130 |
||
Height |
mm |
1635,1885 |
2000 |
||
LV chamber |
Height |
mm |
350,450 |
710 |
|
Circuit breaker cabinet |
Width |
mm |
800 |
—— |
|
Depth |
mm |
1000 |
—— |
||
Height |
mm |
2000 |
—— |
OUTLINE DIMENSION AND FOUNDATION INSTALLATION DIMENSION
Q: Can we get a sample for reference?
A: Yes, as long as the goods are conventional type, and you will be charged sample cost plus related shipping cost. Once you place an order to us, we can return or deduct the sample cost to you.
Q: How to solve the quality problems after sales?
A: Take photos of the quality problems and send to us for our checking and confirming, we will make a satisfied solution for you within 3 days.
Q: What is the lead time?
A: The lead time depends on the quantities ordered, generally within 25-35days upon the receipt of advance payment.
Q: What is your terms of payment ?
A: We accept West Union, T/T, irrevocable L/C at sight. Prefer T/T 30% deposit before production, the balance against copy of B/L.
Q: Can you print our brand on the product?
A: Yes, of course, we also do OEM to print client’s brand on the product