Meet SAE-AMS-DTL -23053/5
Class 1 and 3
Property | Test Method | Typical Performance |
---|---|---|
Tensile strength ( MPa ) | ASTM D 2671 | ≥10.4 |
Ultimate elongation ( % ) | ASTM D 2671 | ≥ 2 00 |
Tensile strength after heat aged ( MPa ) | 1 75 ℃×168h | ≥7.3MPa |
Ultimate elongation after heat aged ( % ) | 1 75 ℃×168h | ≥100 |
Longitudinal chang(%) | ASTM D 2671 | -5% ~ +5% |
Flammability | ASTM D 2671 C method | VW-1 |
Voltage withstand | UL 224, 2500V, 60s | No breakdown |
Heat shock | UL 224 , 250℃×4h | No cracks, flowing or dripping |
Dielectric strength ( kV/mm) | ASTM D 149 | ≥ 15 |
Volume resistivity ( Ω·cm) | ASTM D 876 | ≥ 1014 |
Wallwav Technology was established in 2012. The company is committed to becoming a first-class service provider of wire harness products for automobiles, rail transit, white goods.etc., adhering to a unique and innovative business concept, filling the gap of one-stop service of insulating materials, creating a service chain with insulating products as its core. Insulation pro tection solutions for electrical connections in power, aerospace, automobiles, rail transit, etc.the customers served involve many well-known domestic and foreign large-scale production ises