Wifi Remote Control Thermostat Temperature And Humidity Controller For Medical Cooler
Features
1.Humidity display/ Temperature control
2.Through mobile phones, PC-side control
3.Refrigerator temperature and humidity in real time
4.Over temperature limit / over time limit the App alarm
5.All data stored in the cloud platform
6.Easy for check and analysis,Running status monitoring
7.Monitor and record temperature, humidity
8.Server storage data unlimited
9.Real-time remote monitoring, upload, print, manage records
10.Defrost control/ Light control
11.Power switch/ Value storing
12.Self-testing/ Evap. Fan control
Technical data
1.Temperature display range: -45~99℃
2.Set temperature range: -45~+75℃
Accuracy: ±01℃
3.Temperature sensor: NTC, one sensor(neither positive nor negative)2m(L)
4.Compressor relay : 30A/250VAC
5.Heater: N.O. 10A/250VAC
6.Others: N.O. 5A/250VAC
7.Dimension: 181mm(L)×41mm(W)×47mm(D)
8.Mounting hole dimension: 138mm(L )×32.5mm(W)
9.Main frame dimension: 150mm(L)×110mm(W)×57mm(D)
Circuit diagram
Parameter
Parameter | Function | Set range | Default |
PA | Menu password | 00~50~99 | 82 |
E1 | Lower set point limit | -45℃~retain freshness set temp. | 02℃ |
E2 | Higher set point limit | retain freshness set temp.~75℃ | 30℃ |
E3 | Refrigeration Hysteresis | 01~20℃ | 04℃ |
E4 | Heating hysteresis | 01~20℃ | 06℃ |
E5 | Refrigeration start delay time | 00~10Min | 02Min |
E6 | Heating start delay time | 00~10Min | 00Min |
E7 | Refrigeration and heating | 00~90Min | 15Min |
E8 | Offset on room sensor | -20~20℃ | 00℃ |
E9 | Offset on humidity sensor | -20~20% | 00% |
P1 | Light duration time | 00~180 min 00 is infinite length | 00min |
C1 | High temp. alarmvalue | C2~75℃ | 45℃ |
C2 | low temp. alarmvalue | -45℃~C1 | -35℃ |
C3 | Alarm delay time | 00~60min | 2min |
C4 | Alarm hysteresis | 01~10℃ | 02℃ |
F1 | Defrost duration | 01~90min | 20min |
F2 | Defrost interval | 00~24hours | 4hr |
F4 | Display when defrost | 00=normal display 01=locked display | 00 |
H1 | Fan control | H1=01synchronized with heater and comp., off when defrost H1=02synchronized with heater and comp., open when defrost H1=03 keep running, open when defrost H1=04 keep running, close when defrost | 02 |
A1 | Lowest humidity display | 00~50% | 35% |
A2 | Higher humidity display | 50~99% | 75% |
A3 | Set humidity | 10~85% | 60% |
A4 | Humidify hysteresis | 01~30% | 10% |
A5 | Dehumidify hysteresis | 05~30% | 15% |
A6 | Humidify dehumidify switch time | 01~90min | 10min |
b1 | Dehumidify temp. hysteresis | 01~10℃ | 02℃ |
b2 | Dehumidify duration | 01~20min | 03min |
T1 | Force dehumidify interval | 30~90min | 50min |
T2 | Force dehumidify duration | 01~60min | 10min |
CPA | Change menu password | 00~99(if set to 00, means cancel the password) | 82 |
Relative products