Type | KG316(or KG316T) | ||
Working Voltage | 100, 110, 115, 120, 127 VAC | 220, 230, 240 VAC | 12, 24, 36 VDC |
Resistance Load Switch Capacity | 40A | 25A | 40A |
Power Consumption | <2W | <4W | <2W |
Voltage Range | 85~110% | ||
Power Source Frequency | 50/60HZ | / | |
Power Reserve Time | 5 Years | ||
Contact Capacity(Resistance) | 25A 250VAC | ||
Control Electrical Life | 105 Times | ||
Mechanical Life | 107 Times | ||
Battery Type | AAA Battery with 1.5V | ||
Display | LCD | ||
Setting Switch | 10 Times Open nd 10 Times Off | ||
Timing Control Range | 1 min - 168 hours(1 week) | ||
Average Error | 0.5s/24h at 25℃ | ||
Minimum Interval | 1 min | ||
Main Color | White(or Gray), Black | ||
Temperature | -25℃ ~ +60℃ | ||
Relative Humidity | <95% | ||
Weight | 205g | ||
Dimensions | 120mm * 75mm * 51mm | ||
Installation | Guide Rail & Wall Mounting & Panel | ||
Housing Material | PC Material, Proof Flame |
Q: How to choose the right model of the timers?
A: 1. Three basic types of timers: Digital, mechanical, astronomical timers.
It depends on your preference. Mechanical timers can be set more intuitively. While digital timers have smaller time intervals.
If the timer should be adjusted along with the season changes, an astronomical timer is the only option.
2. Dimensions.
Check up the space for installation. And compare the space with the dimensions of the timers. Make sure the timer can be fit in.
3. Load capacity: Max. voltage, max. current.
For digital types of timers, KG316 has larger load capacity than THC15A and CN101A. If there is enough space for installation, KG316 will be a better choice for large load capacity.
Times can be customized with higher load capacity. Contact us if you have a special requirement.