Basic Info:Waterproof Toroid 220V 120V 12V 24V Transformer Outdoor 15a 200W 250W 300W 500W 800W 1000W for outddor lighting
Type | Waterproof Transformer |
Frequency Characteristics | low frequency |
Output | 220-240VAC |
Shape of Core | ring |
Transport Package | Expoort Standard Carton |
IP Rating | IP64 IP66 Rating for Outdoor Use |
Product Description:
What is electrical datas about Waterproof Toroid 220V 120V 12V 24V Transformer Outdoor 15a 200W 250W 300W 500W 800W 1000W for lighting?
What is the material of Waterproof Toroid 220V 120V 12V 24V Transformer Outdoor 15a 200W 250W 300W 500W 800W 1000W for lighting?
1. Waterproof outdoor toroidal Transformer's Spcification:
WORKING AND SAFETY PROTEETION
Eiectrostatic Shield Magnetic Shield
TemperatureProtection OverCurrent Protection
2. INSULATION
Insulation resistance test(type test):Pri.~sec.500V DC 100 MΩMIN.
HI-POT TEST(100% test):Pass ourdielectric strength test, without any breakdown
Pri.~sec.AC 3.8kV for 5 seconds (leakage current 5mAMAX)
3.TEMPERATURE RISE
Ta=25ºCTest by resistance method At rated load
PRI.& SEC.WINDINGS'TEMPERATURE RISE 75ºCMAX.
4.MAJOR MEASUREMENT FACILITIES:
HI-POT TESTER:CJ2670
INSULATION-RESISTANCE METER:ZC-7
VOL TMETER:T19-V
DC-RESISTANCE METER:QJ44
AMPEREMETER:T19/1-A
5. MAIN PARAMETERS:
Input Voltage:AC 220V 230v 110v (Define the voltage)
Output voltage:AC 12V / 24V (Define the voltage)
Power range:105VA-1KVA
6. Waterproof toroidal Transformer's materials:
* Annular core:Cold rolling directional silicon steel
* Insulation protection:Mylar
* Core Insulation:Polyester 7C
* Primary/Secondary Winding:Enamelled copper wire
* Terminal cannula:PVC canula
* Termial uderlay:Polyester 19C
* Temperature Protection:Thermal Switch
* Pri.Insulation:Polyester 7C
* Insulation protection:Mylar
* Coating insulation:Polyester 5C
* Lead:UL WIRE
* Potted resin:Potted resin
* Body:PP+GFRP
7. Standard conditions and components:
* Transformer should meet "Short-circuit-proof safety isolating transformer (inherently
Or non-inherently) IEC 61558-2-6:09"
* Thermal Switch 17AM 211 120°C Sensata Technologies or equivalent (UL E15962)
* Thermal Fuse A7-5A-F 5A/138°C Aupo Electronics or equivalent (UL E140847)
* Transformer is double insulated (Class II) with Insulation Class B 120°C
* Insulation tests 500VDC 100M ohm min and 4kV for 5 seconds at 5mA max leakage current
8. Application:
9.PACKAGE AND PRODUCTION LINES:
About us
1.We have passed ISO9001:2015,CB,SGS approval and IEC report
2. Flow chart of trading activities:
NO | Step | Days need |
1 | Request for quotation | 1 day |
2 | Making quotations | 1 day |
3 | Offer and counter offer | 3 days |
4 | Sending and receiving samples | 3-10 days |
5 | Sample confirmation | 3 days |
6 | Placing a firm order | 1 day |
7 | Paying and receiving the down payment | 1-4 day |
8 | Factory production & Quality inspection | 15-20 days |
9 | Paying and receiving the balance | 4 days |
10 | Delivery of goods | 1 days |
Contact Information:
Alice
Tianjin Grewin Technology Co.,Ltd.
Website:www.grewin-tech.com
Salesmanager(at)grewin-tech.com