Main Features
High Accuracy;±0.075%F.S
Good stability;
2-wire type;
Solid components, plug-in printed circuit boards;
Small size, light weight, strong and anti-vibration;
The range and zero point are continuously adjustable externally; smart models need to be equipped with Hart handheld programmer/software or adjustment in the shell
The positive migration can reach 500%, the negative migration can reach 600%; the intelligent turndown ratio is 100:1
Adjustable damping;
Good one-way overload protection characteristics;
No mechanical moving parts, less maintenance work;
Unified structure of the whole series; strong interchangeability of parts and components;
Diaphragm material in contact with the medium can be selected (316L, tantalum, Hastelloy C, Monel and other corrosion-resistant materials)
Application
Widely used in pharmaceutical, medical equipment, oil, gas, chemical, urban construction power, metallurgy, textile, aerospace, scientific research, leak detection, automation equipment and other fields.
Measuring medium |
liquid, gas |
Measuring range |
Range 3 0-1.3~7.5kPa |
Range 4 0-6.2~37.4kPa |
|
Range 5 0-31~186.8kPa |
|
Range 6 0-117~690kPa |
|
Range 7 0-345~2068kPa |
|
Range 8 0-1170~6890kPa |
|
Range 9 0-3480~20680kPa |
|
Range 0 0-6890~41370kPa |
|
Accuracy |
±0.1% URL ±0.2% URL |
Signal output |
4~20mA 4~20mA with HART |
Supply voltage |
24VDC(12VDC~45VDC) Explosion-proof type:12~28VDC |
Stability |
±0.1 URL in six months |
Medium temperature |
-40~+100°C |
Storage temperature |
-40~+100°C(without LCD display) -40~+70°C(with LCD display) |
Operating temperature |
-40~+85°C(without LCD display) -30~+60°C(with LCD display) |
Ambient temperature |
-0~-100% relative humidity |
Temperature impact |
±(0.2%URL+0.18%inspection range)/56°C |
Power supply effect |
Less than 0.0059% / V of the output range |
Load effect |
No load is affected unless the supply voltage changes |
Vibration effect |
The vibration effect is ± 0.05% URL / g at 200 Hz in any axial direction. |
EMI/RFI effect |
Between 20 to 1000MHz;field strength up to 30V / M; the output drift less than ± 0.1% range; |
Installation site effect |
Maximum Zero drift is ± 0.25kPa; all zero drift can be corrected. |
Zero point positive and negative migration |
When zero is moving, the minimum range must be larger than or equal to - URL, the maximum range must be less than or equal to + URL. The calibration range must be greater than or equal to the minimum range. |
Zero and range |
Zero and range can be adjusted with the instrument range and zero button, or with the HART handhold remote adjustment. |
Static pressure and over-pressure limit |
Transmitter on any side plus 0 to 13.79MPa pressure will not cause damage. In the 0kPa to the transmitter range of the upper limit of the work to meet the performance requirements. |
Damping time constant |
The time constant is adjustable, incremented by 0.1 seconds, from minimum to 16.0 seconds. |
Explosion-proof grade |
Intrinsically safe: Exia II CT6 Flameproof: Exd II BT5 |
Protection grade |
IP65 |