Enquiries
Message
Home > Products > Other
WSL-GS200 erba biochemistry machine price fully auto biochemistry analyzer clinical analyzer
  • WSL-GS200 erba biochemistry machine price fully auto biochemistry analyzer clinical analyzer

WSL-GS200 erba biochemistry machine price fully auto biochemistry analyzer clinical analyzer

FOB Reference Price
Purchase quantity ()
Minimum order quantity
Payment
Meorient Import & Export  Co.LTD
Meorient Import & Export Co.LTD
China - Hangzhou
Trading Company
Trade Capacity
Export Percentage
Nearest Port
Hangzhou,Shanghai
Accepted Delivery Terms
Employees
5-10人
Accepted Payment Currency
USD,CNY
Average Lead Time
45 Day(s)
Certifications
Product Specifications
--
Product Description
Overview
Quick Details
Type:
Biochemical Analysis System
Brand Name:
MEILISONG
Model Number:
WSL-GS200
Place of Origin:
China
Instrument classification:
Class II
Warranty:
2 years
After-sale Service:
Online technical support
Supply Ability
Supply Ability:
100000 Strand/Strands per Month
Packaging & Delivery
WSL-GS200 erba biochemistry machine price fully auto biochemistry analyzer clinical analyzer
Product Description
Specifications
Type: Fully AutomatedSample Tests/Hour: 200testsSize: Floor Standing Type
System function
Throughput: Up to 225 tests/Hour(not including ISE tests)
Test Method: End point, Fixed time, Kinetic
Test Sequence: Discrete, Random access, STAT can be inserted at anytime. Test sequence can be
sorted by samples or items
Spectrometer: enclosed array of spectrometer and photodiodes, maintenance free.
Reaction detect: monitor 81 cuvettes’s reaction at the same time
Photometric process: the interval time between two consecutive photometric points are exactly the
same.
Pipeline system: pressure auto released pumps and double filters to protect pumps and valves
Gearing: plastic gear leads lower noise and accuracy of positioning of moving parts
Environmental resistance: resistant form dust and water vapor

Sample/Reagent/Stirrer system
Sample volume:2μL~30μL,step by 0.1μL
Sample tray: 12 positions for primary tubes and secondary cups on one tray, provide two trays
convenient for alternate use.
Reagent volume:20μL~300μL, step by 1μL
Reagent tray: embed refrigerated tray provide 30 reagent bottle positions
Reagent bottle: particular reagent bottle without dead volume
Reagent Cooling: continuous cooling system according to the principle of peltier
Probe: inner and outer walls are highly polished leads carry-over <0.1%, level detection and
vertical and horizontal collision protection
Stirrer: paddle stirrer coated with Teflon, stir immediately after the sample was added in.
Water consume: <1.5L/hour
Carry over:Optimized item test sequence and reinforced washing process, lower the carry over and avoid probe being clotted
Reaction system
Cuvette material: UV free plastic
Reaction disc: Discal reaction disc with 81 disposable cuvettes
Reaction volume:150μL~600μL
Heater: solid and sealed heater leads temperature raise rapidly and steady and maintenance free
Temperature: 37℃±0.1℃
Optical system
Light source: 12V 20W, halogen lamp with lifetime more than 2000 hours
Spectrometer: post spectrometer with arrayed and sealed filters, maintenance free
Wavelength: 340nm、405nm、450nm、510nm、546nm、578nm、630nm、670nm
Absorbance range: 0~6
Calibration/QC
Calibration type: single point linear、two points linear、multi-points linear、Logit-4P、Logit-5P、
Spline、Exponential 5P、Polynomial 5P, auto choose the best fittest calibration
curve.
QC type: real time QC、daily QC、day to day QC
QC chart: L-J、Cumulative sum check、Twin Plot
QC rule: Customized QC rule in order to adapt different item’s requirements
Operational system
Operational system: VISTA、Windows XP、Windows2000
Memory: auto save and recover the results
Report format: Customized report format
Status Check: real time check the working status of the analyzer

Power/ Dimension
Voltage: AC 85V~264V, 55Hz±8Hz, Auto adapt according to the input voltage
Power Consume: ≤350VA
Dimension: 815 mm×625 mm×1100mm(L×W×H)Net weight: 90Kg

System function
Throughput: Up to 225 tests/Hour(not including ISE tests)
Test Method: End point, Fixed time, Kinetic
Test Sequence: Discrete, Random access, STAT can be inserted at anytime. Test sequence can be
sorted by samples or items
Spectrometer: enclosed array of spectrometer and photodiodes, maintenance free.
Reaction detect: monitor 81 cuvettes’s reaction at the same time
Photometric process: the interval time between two consecutive photometric points are exactly the
same.
Pipeline system: pressure auto released pumps and double filters to protect pumps and valves
Gearing: plastic gear leads lower noise and accuracy of positioning of moving parts
Environmental resistance: resistant form dust and water vapor

Sample/Reagent/Stirrer system
Sample volume:2μL~30μL,step by 0.1μL
Sample tray: 12 positions for primary tubes and secondary cups on one tray, provide two trays
convenient for alternate use.
Reagent volume:20μL~300μL, step by 1μL
Reagent tray: embed refrigerated tray provide 30 reagent bottle positions
Reagent bottle: particular reagent bottle without dead volume
Reagent Cooling: continuous cooling system according to the principle of peltier
Probe: inner and outer walls are highly polished leads carry-over <0.1%, level detection and
vertical and horizontal collision protection
Stirrer: paddle stirrer coated with Teflon, stir immediately after the sample was added in.
Water consume: <1.5L/hour
Carry over:Optimized item test sequence and reinforced washing process, lower the carry over and avoid probe being clotted
Reaction system
Cuvette material: UV free plastic
Reaction disc: Discal reaction disc with 81 disposable cuvettes
Reaction volume:150μL~600μL
Heater: solid and sealed heater leads temperature raise rapidly and steady and maintenance free
Temperature: 37℃±0.1℃
Optical system
Light source: 12V 20W, halogen lamp with lifetime more than 2000 hours
Spectrometer: post spectrometer with arrayed and sealed filters, maintenance free
Wavelength: 340nm、405nm、450nm、510nm、546nm、578nm、630nm、670nm
Absorbance range: 0~6
Calibration/QC
Calibration type: single point linear、two points linear、multi-points linear、Logit-4P、Logit-5P、
Spline、Exponential 5P、Polynomial 5P, auto choose the best fittest calibration
curve.
QC type: real time QC、daily QC、day to day QC
QC chart: L-J、Cumulative sum check、Twin Plot
QC rule: Customized QC rule in order to adapt different item’s requirements
Operational system
Operational system: VISTA、Windows XP、Windows2000
Memory: auto save and recover the results
Report format: Customized report format
Status Check: real time check the working status of the analyzer

Power/ Dimension
Voltage: AC 85V~264V, 55Hz±8Hz, Auto adapt according to the input voltage
Power Consume: ≤350VA
Dimension: 815 mm×625 mm×1100mm(L×W×H)Net weight: 90Kg

System function
Throughput: Up to 225 tests/Hour(not including ISE tests)
Test Method: End point, Fixed time, Kinetic
Test Sequence: Discrete, Random access, STAT can be inserted at anytime. Test sequence can be
sorted by samples or items
Spectrometer: enclosed array of spectrometer and photodiodes, maintenance free.
Reaction detect: monitor 81 cuvettes’s reaction at the same time
Photometric process: the interval time between two consecutive photometric points are exactly the
same.
Pipeline system: pressure auto released pumps and double filters to protect pumps and valves
Gearing: plastic gear leads lower noise and accuracy of positioning of moving parts
Environmental resistance: resistant form dust and water vapor

Sample/Reagent/Stirrer system
Sample volume:2μL~30μL,step by 0.1μL
Sample tray: 12 positions for primary tubes and secondary cups on one tray, provide two trays
convenient for alternate use.
Reagent volume:20μL~300μL, step by 1μL
Reagent tray: embed refrigerated tray provide 30 reagent bottle positions
Reagent bottle: particular reagent bottle without dead volume
Reagent Cooling: continuous cooling system according to the principle of peltier
Probe: inner and outer walls are highly polished leads carry-over <0.1%, level detection and
vertical and horizontal collision protection
Stirrer: paddle stirrer coated with Teflon, stir immediately after the sample was added in.
Water consume: <1.5L/hour
Carry over:Optimized item test sequence and reinforced washing process, lower the carry over and avoid probe being clotted
Reaction system
Cuvette material: UV free plastic
Reaction disc: Discal reaction disc with 81 disposable cuvettes
Reaction volume:150μL~600μL
Heater: solid and sealed heater leads temperature raise rapidly and steady and maintenance free
Temperature: 37℃±0.1℃
Optical system
Light source: 12V 20W, halogen lamp with lifetime more than 2000 hours
Spectrometer: post spectrometer with arrayed and sealed filters, maintenance free
Wavelength: 340nm、405nm、450nm、510nm、546nm、578nm、630nm、670nm
Absorbance range: 0~6
Calibration/QC
Calibration type: single point linear、two points linear、multi-points linear、Logit-4P、Logit-5P、
Spline、Exponential 5P、Polynomial 5P, auto choose the best fittest calibration
curve.
QC type: real time QC、daily QC、day to day QC
QC chart: L-J、Cumulative sum check、Twin Plot
QC rule: Customized QC rule in order to adapt different item’s requirements
Operational system
Operational system: VISTA、Windows XP、Windows2000
Memory: auto save and recover the results
Report format: Customized report format
Status Check: real time check the working status of the analyzer

Power/ Dimension
Voltage: AC 85V~264V, 55Hz±8Hz, Auto adapt according to the input voltage
Power Consume: ≤350VA
Dimension: 815 mm×625 mm×1100mm(L×W×H)Net weight: 90Kg

System function
Throughput: Up to 225 tests/Hour(not including ISE tests)
Test Method: End point, Fixed time, Kinetic
Test Sequence: Discrete, Random access, STAT can be inserted at anytime. Test sequence can be
sorted by samples or items
Spectrometer: enclosed array of spectrometer and photodiodes, maintenance free.
Reaction detect: monitor 81 cuvettes’s reaction at the same time
Photometric process: the interval time between two consecutive photometric points are exactly the
same.
Pipeline system: pressure auto released pumps and double filters to protect pumps and valves
Gearing: plastic gear leads lower noise and accuracy of positioning of moving parts
Environmental resistance: resistant form dust and water vapor

Sample/Reagent/Stirrer system
Sample volume:2μL~30μL,step by 0.1μL
Sample tray: 12 positions for primary tubes and secondary cups on one tray, provide two trays
convenient for alternate use.
Reagent volume:20μL~300μL, step by 1μL
Reagent tray: embed refrigerated tray provide 30 reagent bottle positions
Reagent bottle: particular reagent bottle without dead volume
Reagent Cooling: continuous cooling system according to the principle of peltier
Probe: inner and outer walls are highly polished leads carry-over <0.1%, level detection and
vertical and horizontal collision protection
Stirrer: paddle stirrer coated with Teflon, stir immediately after the sample was added in.
Water consume: <1.5L/hour
Carry over:Optimized item test sequence and reinforced washing process, lower the carry over and avoid probe being clotted
Reaction system
Cuvette material: UV free plastic
Reaction disc: Discal reaction disc with 81 disposable cuvettes
Reaction volume:150μL~600μL
Heater: solid and sealed heater leads temperature raise rapidly and steady and maintenance free
Temperature: 37℃±0.1℃
Optical system
Light source: 12V 20W, halogen lamp with lifetime more than 2000 hours
Spectrometer: post spectrometer with arrayed and sealed filters, maintenance free
Wavelength: 340nm、405nm、450nm、510nm、546nm、578nm、630nm、670nm
Absorbance range: 0~6
Calibration/QC
Calibration type: single point linear、two points linear、multi-points linear、Logit-4P、Logit-5P、
Spline、Exponential 5P、Polynomial 5P, auto choose the best fittest calibration
curve.
QC type: real time QC、daily QC、day to day QC
QC chart: L-J、Cumulative sum check、Twin Plot
QC rule: Customized QC rule in order to adapt different item’s requirements
Operational system
Operational system: VISTA、Windows XP、Windows2000
Memory: auto save and recover the results
Report format: Customized report format
Status Check: real time check the working status of the analyzer

Power/ Dimension
Voltage: AC 85V~264V, 55Hz±8Hz, Auto adapt according to the input voltage
Power Consume: ≤350VA
Dimension: 815 mm×625 mm×1100mm(L×W×H)Net weight: 90Kg

System function
Throughput: Up to 225 tests/Hour(not including ISE tests)
Test Method: End point, Fixed time, Kinetic
Test Sequence: Discrete, Random access, STAT can be inserted at anytime. Test sequence can be
sorted by samples or items
Spectrometer: enclosed array of spectrometer and photodiodes, maintenance free.
Reaction detect: monitor 81 cuvettes’s reaction at the same time
Photometric process: the interval time between two consecutive photometric points are exactly the
same.
Pipeline system: pressure auto released pumps and double filters to protect pumps and valves
Gearing: plastic gear leads lower noise and accuracy of positioning of moving parts
Environmental resistance: resistant form dust and water vapor

Sample/Reagent/Stirrer system
Sample volume:2μL~30μL,step by 0.1μL
Sample tray: 12 positions for primary tubes and secondary cups on one tray, provide two trays
convenient for alternate use.
Reagent volume:20μL~300μL, step by 1μL
Reagent tray: embed refrigerated tray provide 30 reagent bottle positions
Reagent bottle: particular reagent bottle without dead volume
Reagent Cooling: continuous cooling system according to the principle of peltier
Probe: inner and outer walls are highly polished leads carry-over <0.1%, level detection and
vertical and horizontal collision protection
Stirrer: paddle stirrer coated with Teflon, stir immediately after the sample was added in.
Water consume: <1.5L/hour
Carry over:Optimized item test sequence and reinforced washing process, lower the carry over and avoid probe being clotted
Reaction system
Cuvette material: UV free plastic
Reaction disc: Discal reaction disc with 81 disposable cuvettes
Reaction volume:150μL~600μL
Heater: solid and sealed heater leads temperature raise rapidly and steady and maintenance free
Temperature: 37℃±0.1℃
Optical system
Light source: 12V 20W, halogen lamp with lifetime more than 2000 hours
Spectrometer: post spectrometer with arrayed and sealed filters, maintenance free
Wavelength: 340nm、405nm、450nm、510nm、546nm、578nm、630nm、670nm
Absorbance range: 0~6
Calibration/QC
Calibration type: single point linear、two points linear、multi-points linear、Logit-4P、Logit-5P、
Spline、Exponential 5P、Polynomial 5P, auto choose the best fittest calibration
curve.
QC type: real time QC、daily QC、day to day QC
QC chart: L-J、Cumulative sum check、Twin Plot
QC rule: Customized QC rule in order to adapt different item’s requirements
Operational system
Operational system: VISTA、Windows XP、Windows2000
Memory: auto save and recover the results
Report format: Customized report format
Status Check: real time check the working status of the analyzer

Power/ Dimension
Voltage: AC 85V~264V, 55Hz±8Hz, Auto adapt according to the input voltage
Power Consume: ≤350VA
Dimension: 815 mm×625 mm×1100mm(L×W×H)Net weight: 90Kg
System function
Throughput: Up to 225 tests/Hour(not including ISE tests)
Test Method: End point, Fixed time, Kinetic
Test Sequence: Discrete, Random access, STAT can be inserted at anytime. Test sequence can be
sorted by samples or items
Spectrometer: enclosed array of spectrometer and photodiodes, maintenance free.
Reaction detect: monitor 81 cuvettes’s reaction at the same time
Photometric process: the interval time between two consecutive photometric points are exactly the
same.
Pipeline system: pressure auto released pumps and double filters to protect pumps and valves
Gearing: plastic gear leads lower noise and accuracy of positioning of moving parts
Environmental resistance: resistant form dust and water vapor

Sample/Reagent/Stirrer system
Sample volume:2μL~30μL,step by 0.1μL
Sample tray: 12 positions for primary tubes and secondary cups on one tray, provide two trays
convenient for alternate use.
Reagent volume:20μL~300μL, step by 1μL
Reagent tray: embed refrigerated tray provide 30 reagent bottle positions
Reagent bottle: particular reagent bottle without dead volume
Reagent Cooling: continuous cooling system according to the principle of peltier
Probe: inner and outer walls are highly polished leads carry-over <0.1%, level detection and
vertical and horizontal collision protection
Stirrer: paddle stirrer coated with Teflon, stir immediately after the sample was added in.
Water consume: <1.5L/hour
Carry over:Optimized item test sequence and reinforced washing process, lower the carry over and avoid probe being clotted
Reaction system
Cuvette material: UV free plastic
Reaction disc: Discal reaction disc with 81 disposable cuvettes
Reaction volume:150μL~600μL
Heater: solid and sealed heater leads temperature raise rapidly and steady and maintenance free
Temperature: 37℃±0.1℃
Optical system
Light source: 12V 20W, halogen lamp with lifetime more than 2000 hours
Spectrometer: post spectrometer with arrayed and sealed filters, maintenance free
Wavelength: 340nm、405nm、450nm、510nm、546nm、578nm、630nm、670nm
Absorbance range: 0~6
Calibration/QC
Calibration type: single point linear、two points linear、multi-points linear、Logit-4P、Logit-5P、
Spline、Exponential 5P、Polynomial 5P, auto choose the best fittest calibration
curve.
QC type: real time QC、daily QC、day to day QC
QC chart: L-J、Cumulative sum check、Twin Plot
QC rule: Customized QC rule in order to adapt different item’s requirements
Operational system
Operational system: VISTA、Windows XP、Windows2000
Memory: auto save and recover the results
Report format: Customized report format
Status Check: real time check the working status of the analyzer

Power/ Dimension
Voltage: AC 85V~264V, 55Hz±8Hz, Auto adapt according to the input voltage
Power Consume: ≤350VA
Dimension: 815 mm×625 mm×1100mm(L×W×H)Net weight: 90Kg
System function
Throughput: Up to 225 tests/Hour(not including ISE tests)
Test Method: End point, Fixed time, Kinetic
Test Sequence: Discrete, Random access, STAT can be inserted at anytime. Test sequence can be
sorted by samples or items
Spectrometer: enclosed array of spectrometer and photodiodes, maintenance free.
Reaction detect: monitor 81 cuvettes’s reaction at the same time
Photometric process: the interval time between two consecutive photometric points are exactly the
same.
Pipeline system: pressure auto released pumps and double filters to protect pumps and valves
Gearing: plastic gear leads lower noise and accuracy of positioning of moving parts
Environmental resistance: resistant form dust and water vapor

Sample/Reagent/Stirrer system
Sample volume:2μL~30μL,step by 0.1μL
Sample tray: 12 positions for primary tubes and secondary cups on one tray, provide two trays
convenient for alternate use.
Reagent volume:20μL~300μL, step by 1μL
Reagent tray: embed refrigerated tray provide 30 reagent bottle positions
Reagent bottle: particular reagent bottle without dead volume
Reagent Cooling: continuous cooling system according to the principle of peltier
Probe: inner and outer walls are highly polished leads carry-over <0.1%, level detection and
vertical and horizontal collision protection
Stirrer: paddle stirrer coated with Teflon, stir immediately after the sample was added in.
Water consume: <1.5L/hour
Carry over:Optimized item test sequence and reinforced washing process, lower the carry over and avoid probe being clotted
Reaction system
Cuvette material: UV free plastic
Reaction disc: Discal reaction disc with 81 disposable cuvettes
Reaction volume:150μL~600μL
Heater: solid and sealed heater leads temperature raise rapidly and steady and maintenance free
Temperature: 37℃±0.1℃
Optical system
Light source: 12V 20W, halogen lamp with lifetime more than 2000 hours
Spectrometer: post spectrometer with arrayed and sealed filters, maintenance free
Wavelength: 340nm、405nm、450nm、510nm、546nm、578nm、630nm、670nm
Absorbance range: 0~6
Calibration/QC
Calibration type: single point linear、two points linear、multi-points linear、Logit-4P、Logit-5P、
Spline、Exponential 5P、Polynomial 5P, auto choose the best fittest calibration
curve.
QC type: real time QC、daily QC、day to day QC
QC chart: L-J、Cumulative sum check、Twin Plot
QC rule: Customized QC rule in order to adapt different item’s requirements
Operational system
Operational system: VISTA、Windows XP、Windows2000
Memory: auto save and recover the results
Report format: Customized report format
Status Check: real time check the working status of the analyzer

Power/ Dimension
Voltage: AC 85V~264V, 55Hz±8Hz, Auto adapt according to the input voltage
Power Consume: ≤350VA
Dimension: 815 mm×625 mm×1100mm(L×W×H)Net weight: 90Kg
System function
Throughput: Up to 225 tests/Hour(not including ISE tests)
Test Method: End point, Fixed time, Kinetic
Test Sequence: Discrete, Random access, STAT can be inserted at anytime. Test sequence can be
sorted by samples or items
Spectrometer: enclosed array of spectrometer and photodiodes, maintenance free.
Reaction detect: monitor 81 cuvettes’s reaction at the same time
Photometric process: the interval time between two consecutive photometric points are exactly the
same.
Pipeline system: pressure auto released pumps and double filters to protect pumps and valves
Gearing: plastic gear leads lower noise and accuracy of positioning of moving parts
Environmental resistance: resistant form dust and water vapor

Sample/Reagent/Stirrer system
Sample volume:2μL~30μL,step by 0.1μL
Sample tray: 12 positions for primary tubes and secondary cups on one tray, provide two trays
convenient for alternate use.
Reagent volume:20μL~300μL, step by 1μL
Reagent tray: embed refrigerated tray provide 30 reagent bottle positions
Reagent bottle: particular reagent bottle without dead volume
Reagent Cooling: continuous cooling system according to the principle of peltier
Probe: inner and outer walls are highly polished leads carry-over <0.1%, level detection and
vertical and horizontal collision protection
Stirrer: paddle stirrer coated with Teflon, stir immediately after the sample was added in.
Water consume: <1.5L/hour
Carry over:Optimized item test sequence and reinforced washing process, lower the carry over and avoid probe being clotted
Reaction system
Cuvette material: UV free plastic
Reaction disc: Discal reaction disc with 81 disposable cuvettes
Reaction volume:150μL~600μL
Heater: solid and sealed heater leads temperature raise rapidly and steady and maintenance free
Temperature: 37℃±0.1℃
Optical system
Light source: 12V 20W, halogen lamp with lifetime more than 2000 hours
Spectrometer: post spectrometer with arrayed and sealed filters, maintenance free
Wavelength: 340nm、405nm、450nm、510nm、546nm、578nm、630nm、670nm
Absorbance range: 0~6
Calibration/QC
Calibration type: single point linear、two points linear、multi-points linear、Logit-4P、Logit-5P、
Spline、Exponential 5P、Polynomial 5P, auto choose the best fittest calibration
curve.
QC type: real time QC、daily QC、day to day QC
QC chart: L-J、Cumulative sum check、Twin Plot
QC rule: Customized QC rule in order to adapt different item’s requirements
Operational system
Operational system: VISTA、Windows XP、Windows2000
Memory: auto save and recover the results
Report format: Customized report format
Status Check: real time check the working status of the analyzer

Power/ Dimension
Voltage: AC 85V~264V, 55Hz±8Hz, Auto adapt according to the input voltage
Power Consume: ≤350VA
Dimension: 815 mm×625 mm×1100mm(L×W×H)Net weight: 90Kg
System function
Throughput: Up to 225 tests/Hour(not including ISE tests)
Test Method: End point, Fixed time, Kinetic
Test Sequence: Discrete, Random access, STAT can be inserted at anytime. Test sequence can be
sorted by samples or items
Spectrometer: enclosed array of spectrometer and photodiodes, maintenance free.
Reaction detect: monitor 81 cuvettes’s reaction at the same time
Photometric process: the interval time between two consecutive photometric points are exactly the
same.
Pipeline system: pressure auto released pumps and double filters to protect pumps and valves
Gearing: plastic gear leads lower noise and accuracy of positioning of moving parts
Environmental resistance: resistant form dust and water vapor

Sample/Reagent/Stirrer system
Sample volume:2μL~30μL,step by 0.1μL
Sample tray: 12 positions for primary tubes and secondary cups on one tray, provide two trays
convenient for alternate use.
Reagent volume:20μL~300μL, step by 1μL
Reagent tray: embed refrigerated tray provide 30 reagent bottle positions
Reagent bottle: particular reagent bottle without dead volume
Reagent Cooling: continuous cooling system according to the principle of peltier
Probe: inner and outer walls are highly polished leads carry-over <0.1%, level detection and
vertical and horizontal collision protection
Stirrer: paddle stirrer coated with Teflon, stir immediately after the sample was added in.
Water consume: <1.5L/hour
Carry over:Optimized item test sequence and reinforced washing process, lower the carry over and avoid probe being clotted
Reaction system
Cuvette material: UV free plastic
Reaction disc: Discal reaction disc with 81 disposable cuvettes
Reaction volume:150μL~600μL
Heater: solid and sealed heater leads temperature raise rapidly and steady and maintenance free
Temperature: 37℃±0.1℃
Optical system
Light source: 12V 20W, halogen lamp with lifetime more than 2000 hours
Spectrometer: post spectrometer with arrayed and sealed filters, maintenance free
Wavelength: 340nm、405nm、450nm、510nm、546nm、578nm、630nm、670nm
Absorbance range: 0~6
Calibration/QC
Calibration type: single point linear、two points linear、multi-points linear、Logit-4P、Logit-5P、
Spline、Exponential 5P、Polynomial 5P, auto choose the best fittest calibration
curve.
QC type: real time QC、daily QC、day to day QC
QC chart: L-J、Cumulative sum check、Twin Plot
QC rule: Customized QC rule in order to adapt different item’s requirements
Operational system
Operational system: VISTA、Windows XP、Windows2000
Memory: auto save and recover the results
Report format: Customized report format
Status Check: real time check the working status of the analyzer

Power/ Dimension
Voltage: AC 85V~264V, 55Hz±8Hz, Auto adapt according to the input voltage
Power Consume: ≤350VA
Dimension: 815 mm×625 mm×1100mm(L×W×H)Net weight: 90Kg

Shipping Information:
G.W: 160kg
Packing Size: 0.8m,1m,1.35m
WSL-GS200 erba biochemistry machine price fully auto biochemistry analyzer clinical analyzer from China supplier
WSL-GS200 erba biochemistry machine price fully auto biochemistry analyzer clinical analyzer from China supplier
WSL-GS200 erba biochemistry machine price fully auto biochemistry analyzer clinical analyzer from China supplier
WSL-GS200 erba biochemistry machine price fully auto biochemistry analyzer clinical analyzer from China supplier
WSL-GS200 erba biochemistry machine price fully auto biochemistry analyzer clinical analyzer from China supplier
Specification
Product Code
WSL-GS200
After-sales Service Provided
Provide online technical services
Warranty
2 Years
Certification
CE
Place of Origin
China,Guangdong
Company Profile
Established in 2012, Meilisong is a Hong Kong-sourced manufacturer with subsidiaries in Shenzhen and Guangzhou, China. We sincerely serve people in need, and have now become a first-class comprehensive supplier of medical equipment and facilities, providing anesthesia breathing machines, ultrasound machines, medical consumables, laboratory products and other items. We promise: 7*24 service, reliable supply of comprehensive medical equipment, adequate financial support, reliable quality, extensive pharmaceutical resources and professional medical team Although our mission statement is bold, it is what we truly believe in: "Quality is the life of the product, the style is the product soul"
1.Production line equipment photos
WSL-GS200 erba biochemistry machine price fully auto biochemistry analyzer clinical analyzer from China supplier
2.Photos of the Canton Fair and our customers
WSL-GS200 erba biochemistry machine price fully auto biochemistry analyzer clinical analyzer from China supplier
Why Choose Us
WSL-GS200 erba biochemistry machine price fully auto biochemistry analyzer clinical analyzer from China supplier
WSL-GS200 erba biochemistry machine price fully auto biochemistry analyzer clinical analyzer from China supplier
WSL-GS200 erba biochemistry machine price fully auto biochemistry analyzer clinical analyzer from China supplier
WSL-GS200 erba biochemistry machine price fully auto biochemistry analyzer clinical analyzer from China supplier
WSL-GS200 erba biochemistry machine price fully auto biochemistry analyzer clinical analyzer from China supplier
FAQ
1. Are you a factory or a trader??
We are the source factory of medical equipment in China. We have our own factory and R&D team, as well as foreign trade export companies.

2. How can we guarantee quality?
Always a pre-production sample before mass production;
Always final Inspection before shipment;

3. Why should you buy from us not from other suppliers?
1.Professional manufacturer with more than 10 years 2.Factory direct price 3.Delivery date on time 4.Responsible after-sale service 5.Small order is acceptable 6.Good quality assurance
Contact US!
WSL-GS200 erba biochemistry machine price fully auto biochemistry analyzer clinical analyzer from China supplier
No desirable products?
Sourcing assistant>
How to start your business
  • Step 1
    Find your interested products by search keywords
  • Step 2
    Contact the supplier by clicking ”Enquire” or “request meeting” button, otherwise, you also could consult our import consultant.
  • Step 3
    After verifying your email, get response from suppliers or our trade manager will contact you as soon as possible
  • Step 4
    Set up meeting with the Chinese supplier without language barrier
Send Enquiry
ToLily Liu
Meorient Import & Export Co.LTD
Enquire
Popular Searches
lathersbuchertether.thermosatherosfortherusherfinetherhb thermfortherthoraether.thermoslocherfletcher