Model No. | Rate Current | Output Voltage | Applicable For Pump | External Of Drive Size(mm) | MPPT Voltage (VDC) | Weight (kg) |
SP380-4T-022G | 45A | 380V-440V | 22KW | 395*295*275 | 486-750 | 12 |
SP380-4T-030G | 60A | 380V-440V | 30KW | 640*410*390 | 486-750 | 17 |
SP380-4T-037G | 75A | 380V-440V | 37KW | 640*410*390 | 486-750 | 17.5 |
SP380-4T-045G | 91A | 380V-440V | 45KW | 700*410*460 | 486-750 | 35 |
SP380-4T-055G | 110A | 380V-440V | 55KW | 700*410*460 | 486-750 | 36 |
SP380-4T-075G | 150A | 380V-440V | 75KW | 680*485*415 | 486-750 | 45 |
SP380-4T-093G | 180A | 380V-440V | 93KW | 680*485*415 | 486-750 | 51 |
SP380-4T-110G | 220A | 380V-440V | 110KW | 680*485*415 | 486-750 | 54 |
SP380-4T-132G | 250A | 380V-440V | 132KW | 885*535*370 | 486-750 | 86 |
SP380-4T-160G | 310A | 380V-440V | 160KW | 885*535*370 | 486-750 | 90 |
SP380-4T-***G | ***A | 380V-440V | 185-400KW | ******* | 486-750 | *** |
Technical Specifications | ||
Recommended MPPT Voltage Range | Vmpp 280 to 375VDC for 2S model ( 150V to 450VDC input, 3PH 220 to 240VAC output) | |
Vmpp 486 to 750VDC for 4T model ( 250V to 800VDC input, 3PH 380 to 440VAC output) | ||
Recommended Input Voltage (Voc and Vmpp) | Voc 355V DC, Vmpp 310V DC for 2S model or 220V AC pumps | |
Voc 620V DC, Vmpp 540V DC for 4T model or 380V AC pumps | ||
Motor type | Control for permanent magnet synchronous motor(PMSM) and asynchronous motor(AM) | |
Input Power | DC power from solar arrays or AC grid power | |
Maximum DC Power Input | 450VDC for 220V AC Pump / 800VDC for 380V AC Pump | |
Rated Output Voltage | 3-phase 220V or 3-phase 380V/440V | |
Output Frequency Range | 0~50/60HZ | |
MPPT Efficiency | 99.60% | |
Ambient Temperature Range | -10℃ TO 50℃ | |
Solar Pump Control Special Performance | MPPT ( maximum power point tracking), CVT (constant voltage tracking), auto/manual operation, dry run protection, low stop frequency protection, minimum power input, motor maximum current protection, flow calculating, energy generated calculating | |
Protection Function | Phase loss protection, phase short circuit protection, ground to phase circuit protection, input and output short circuit protection | |
Protection Degree | IP20-Air force cooling | |
Running Mode | MPPT,CVT, variable frequency mode | |
Altitude | Below 1000m; above 1000m, derated 1% for every additional 100m | |
Standard | CE certificate (Design based on vector control inverter) |