Enquiries
Message
Home > Products > Other
USA MAKE RO MEMBRANES MODEL LCLE 4040.
  • USA MAKE RO MEMBRANES MODEL LCLE 4040.

USA MAKE RO MEMBRANES MODEL LCLE 4040.

FOB Reference Price
Purchase quantity ()
Minimum order quantity
Payment
Meorient Import & Export  Co.LTD
Meorient Import & Export Co.LTD
China - Hangzhou
Trading Company
Trade Capacity
Export Percentage
Nearest Port
Hangzhou,Shanghai
Accepted Delivery Terms
Employees
5-10人
Accepted Payment Currency
USD,CNY
Average Lead Time
45 Day(s)
Certifications
Product Specifications
--
Product Description
Overview
Quick Details
Condition:
New
Applicable Industries:
Hotels, Garment Shops, Building Material Shops, Manufacturing Plant, Machinery Repair Shops, Food & Beverage Factory, Farms, Restaurant, Home Use, Retail, Food Shop, Printing Shops, Construction works , Energy & Mining, Food & Beverage Shops, Advertising Company
Showroom Location:
India
Video outgoing-inspection:
Provided
Machinery Test Report:
Provided
Marketing Type:
Hot Product 2019
Warranty of core components:
1 Year
Core Components:
MEMBRANE
Place of Origin:
Delhi, India
Brand Name:
FILMTEC
Material:
POLYAMIDE, POLYAMIDE THIN FILM COMPOSITE
Weight:
10
Size:
4040
Power:
0
Warranty:
1 Year, 12 Months
Productivity:
250L/Hour
Product name:
RO Membrane
Application:
Remove Harmful Material
Type:
Industrial Reverse Osmosis Membrane
Name:
Seawater Desalination RO Plants
Usage:
Reverse Osmosis System Pure Water
Function:
Remove Salt TDS
Certification:
NSF
Capacity:
250 LPH
After Warranty Service:
Video technical support
Local Service Location:
India
After-sales Service Provided:
Video technical support
Supply Ability
Supply Ability:
1000 Unit/Units per Month
Packaging & Delivery

 

FILMTEC Membranes

 Large Commercial 4040 Reverse Osmosis Elements

 

Features                                                                                                                                                                                     LC 4040 product range are available to meet a wide variety of customer needs in commercial applications, from producing high purity water to delivering low total system costs. Our  fully automated element production enables the most consistent products in the industry that minimizes the total cost of ownership of water treatment systems.

 

 ·         LC HR-4040 produces high quality water with our state of the art RO membrane.

 ·          LC LE-4040 delivers high quality water at low pressure at harsh water conditions, using Dow’s innovative, proprietary technology for     low energy applications.

 

Product Specifications

 

 

 

Part Number

Feed Spacer

Permeate Flow Rate gpd

Min. Salt

Stabilized Salt

Product

Dry (Wet)

Thickness (mil)

 

(m3/d)

Rejection (%)

Rejection (%)

LC HR-4040

343771 / (343770)

28

2900

(11)

99.5

99.7

LC LE-4040

356603 / (356602)

28

2500

(9.5)

99.0

99.2

1.    Permeate flow and salt rejection based on the following test conditions: 2000 ppm NaCl, 77°F (25°C), 15% recovery, pH 8, and applied pressure 225 psig for LC HR and 125 psig for LC LE

 

2.    Permeate flows for individual elements may vary +/-15%.

3.    For the purpose of improvement, specifications may be updated periodically.

 

 

 

 

 

 

 

 

 

LC HR-4040

Solute

NH4+

NO3-

SiO2

Boron

 

 

Typical rejection (%)

98.8

98.2

99.8

80.0

 

 

 

Operating Limits


 

 

Membrane type

Polyamide Thin-Film Composite

Maximum operating temperaturea

113°F (45°C)

Maximum operating pressure

600 psig (41 bar)

Maximum pressure drop

15 psig (1.0 bar)

Maximum feed flow rate, gpm (m3/h)

16 gpm (3.6 (m3/h))

pH range, continuous operationa

2

- 11

pH range, short-term cleaningb

1

– 13

Maximum Feed Silt Density Index

SDI 5

Free chlorine concentrationc

< 0.1 ppm

 

 

a.        Maximum temperature for continuous operation above PH 10 is 95°F (35°C).

b.        Refer to Cleaning Guidelines in specification sheet 609-23010.

 

c.        Under certain conditions, the presence of free chlorine and other oxidizing agents will cause premature membrane failure. Since oxidation damage is not covered under warranty, Dow recommends removing residual free chlorine and other oxidants by pretreatment prior to membrane exposure. Please refer to technical bulletin 609-22010 for more information.

 

  

Note 

 

 

Proper start-up of reverse osmosis water treatment systems is essential to prepare the membranes for operating service and to prevent membrane damage due to overfeeding or hydraulic shock. Following the proper start-up sequence also helps ensure that system operating parameters conform to design specifications so that system water quality and productivity goals can be achieved.

Before initiating system start-up procedures, membrane pretreatment, loading of the membrane elements, instrument calibration and other system checks should be completed.

Please refer to the application information literature entitled “Start-Up Sequence” (Form No. 609-02077) for more information.

 

Avoid any abrupt pressure or cross-flow variations on the spiral elements during start-up, shutdown, cleaning or other sequences to prevent possible membrane damage. During start-up, a gradual change from a standstill to operating state is recommended as follows:

 

·         Feed pressure should be increased gradually over a 30-60 second time frame.

 

·         Cross-flow velocity at set operating point should be achieved gradually over 15-20 seconds.

·         Permeate obtained from first hour of operation should be discarded.

 

Keep elements moist at all times after initial wetting.

 

If operating limits and guidelines given in this Product Bulletin are not strictly followed, the limited warranty in Form No. 609-35010 will be null and void.

 

To prevent biological growth during prolonged system shutdowns, it is recommended that membrane elements be immersed in a preservative solution.

 

The customer is fully responsible for the effects of incompatible chemicals and lubricants on elements.

Maximum pressure drop across an entire pressure vessel (housing) is 50 psi (3.4 bar).

 

Avoid static permeate-side backpressure at all times.

 

.

 

 

 

 

 

 

 

 

 

                                                                                                                                                                                          

 
 
 
 
 
 
 
No desirable products?
Sourcing assistant>
How to start your business
  • Step 1
    Find your interested products by search keywords
  • Step 2
    Contact the supplier by clicking ”Enquire” or “request meeting” button, otherwise, you also could consult our import consultant.
  • Step 3
    After verifying your email, get response from suppliers or our trade manager will contact you as soon as possible
  • Step 4
    Set up meeting with the Chinese supplier without language barrier
Send Enquiry
ToLily Liu
Meorient Import & Export Co.LTD
Enquire
Popular Searches
lathersbuchertether.thermosatherosfortherusherfinetherhb thermfortherthoraether.thermoslocherfletcher