ASCO SOLENOID INTERFACE ELECTRICAL CHARACTERISTICS | ||||||||||||||||||
prefix option | power ratings | operator ambient temperature range (TS) | safety code | electrical enclosure protection (EN 60529) | replacement coil | |||||||||||||
inrush ~ | holding ~ | hot/cold = | ~ | = | ||||||||||||||
VA | VA | W | W | °C | 230 V / 50 Hz | 24 V DC | ||||||||||||
Basic power (BP) | ||||||||||||||||||
SC | 55 | 23 | 10.5 | 9/11.2 | -40to+75 | EN 60730 | moulded IP65 | 400-425-117 | 400-425-142 | |||||||||
SCDU | 55 | 23 | 10.5 | 9/11.2 | -40to+75 | II 3D IP65 T135°C(~)/T 200°C(=) | moulded IP65 | _ | _ | |||||||||
WP/WS | 55 | 23 | 10.5 | 9/11.2 | -40to+75 | EN 60730 | steel IP67 | 400-405-117 | 400-405-142 | |||||||||
WPDU/WSDU | 55 | 23 | 10.5 | 9/11.2 | -40to+75 | II 3D IP67 T 200°C | steel IP67 | _ | _ | |||||||||
(WS) NF/NL | 55 | 23 | 10.5 | _ | -60to+25 /40/60 | II 2G/D EEx d IIC T6/T5/T4 | alu/steel/cast iron IP67 | 400-405-117 | _ | |||||||||
(WS) NF/NL | _ | _ | _ | 9/11.2 | -60to+25 /40/60 | II 2G/D EEx d IIC T6/T5/T4 | alu/steel/cast iron IP67 | _ | 400-405-142 | |||||||||
NK | 55 | 23 | 10.5 | 9/11.2 | -40to+50 /60 | II 2G/D EEx d IIB+H2 T4(~/=) | aluminium IP65 | 400-405-117 | 400-405-142 | |||||||||
EM/WSEM | 55 | 23 | 10.5 | 9/11.2 | -40to+40 | II 2G/D EEx em II T3 | steel IP67 | 400-909-117 | 400-913-142 | |||||||||
PV | 55 | 23 | 10.5 | 9/11.2 | -40to+65 | II 2G/D EEx m II T3(~)T4(=) | moulded IP65 | _ | _ | |||||||||
EF | 55 | 23 | 10.5 | 9/11.2 | -40to+54 /40 | NEMA type 7 and 9 | NEMA 4X | 238-610-058 | 238-710-006 | |||||||||
ZN | 55 | 23 | 10.5 | 9/11.2 | -20to+50 | II 3G/D EEx nA II T3 | moulded IP65 | _ | _ | |||||||||
Low power (LP) | ||||||||||||||||||
SC | 1.5 | 1.5 | 1.5 | 1,7/1,7 | -40 to +60 | EN 60730 | moulded IP65 | 400-925-097 | 400-925-042 | |||||||||
WP/WS | 1.5 | 1.5 | 1.5 | 1,7/1,7 | -40 to +60 | EN 60730 | steel IP67 | 400-926-097 | 400-926-042 | |||||||||
(WS) NF/NL | _ | _ | 1.9 | - / 1,8 | -60 to + 75 /80 | II 2G/D EEx d IIC T6/T5 | alu/steel/cast iron IP67 | _ | _ | |||||||||
EM/WSEM | 1.5 | 1.5 | 1.5 | 1,7/1,7 | -60 to + 40 /55 | II 2G/D EEx em II T6/T5 | steel IP67 | _ | _ | |||||||||
PV | _ | _ | _ | 1,7/1,7 | -40 to +60 | II 2G/D EEx m II T4 | moulded IP65 | _ | _ | |||||||||
EF | _ | _ | _ | 1,7/1,7 | -40 to +40 | NEMA type 7 and 9 | NEMA 4X | _ | _ | |||||||||
ISSC | _ | _ | _ | 0,4/0,4 | -40 to +60 | II 2G/D EEx ia IIC T6 | moulded IP65 | _ | 268-976-001 | |||||||||
WPIS | _ | _ | _ | 0,4/0,4 | -40 to +60 | II 2G/D EEx ia IIC T6 | steel IP67 | _ | 268-900-001 | |||||||||
ZN | _ | _ | _ | 1,7/1,7 | -20 to +50 | II 3G/D EEx nA II T3 | moulded IP65 | _ | _ |