Trusted medical manual of neonatal aneroid blood pressure monitoring device
  • Trusted medical manual of neonatal aneroid blood pressure monitoring device

Trusted medical manual of neonatal aneroid blood pressure monitoring device

FOB Reference Price
Purchase quantity ()
Minimum order quantity
Payment
Meorient Import & Export  Co.LTD
Meorient Import & Export Co.LTD
China - Hangzhou
Trading Company
Trade Capacity
Export Percentage
Nearest Port
Hangzhou,Shanghai
Accepted Delivery Terms
Employees
5-10人
Accepted Payment Currency
USD,CNY
Average Lead Time
45 Day(s)
Certifications
Product Specifications
--
Product Description
Overview
Quick Details
Place of Origin:
Jiangsu, China
Brand Name:
OEM
Model Number:
aneroid sphygmomanometer with stethoscope
Power Source:
Manual
Warranty:
1 Year
After-sale Service:
Online technical support
Power Supply Mode:
Plug-in
Material:
Steel
Shelf Life:
1years
Quality Certification:
CE ISO
Instrument classification:
Class I
Safety standard:
EN 149 -2001+A1-2009
Type:
Blood Pressure Monitor
keyword:
aneroid sphygmomanometer
Gauge:
zinc alloy, 120 grams
Cuff:
nylon
Bulb:
PVC
Stethoscope:
single head / dual head
MOQ:
1000 pcs
Feature:
high quality, low price
Sample:
available
Usage:
measure blood pressure
Supply Ability
Supply Ability:
100000 Piece/Pieces per Month aneroid sphygmomanometer
Packaging & Delivery

Trusted medical manual of neonatal aneroid blood pressure monitoring device

Product name parts of medical aneroid sphygmomanometer and stethoscope

Gauge

zinc alloy, 120 grams

Cuff

 nylon

Bulb

PVC

Stethoscope

single head / dual head

Certificate

CE & ISO

Usage

measure blood pressure

 

  • Product description:

Aneroid sphygmomanometer is a device what used to measure blood pressure, comprising an inflatable cuff to restrict blood flow and mechanical manometer to measure the pressure. It is always used

together with Stethoscopes.

 

  • Aneroid Sphygmomanometer Instruction:

a. The product is in compliance with EN1060Non-invasive sphygmomanometers;

b. Operating procedure:

1. Position the pressure cuff

Practice the following procedure several times to become familiar with the equipment. Before taking your blood pressure. Plan to relax and rest for at least 15 minutes. This will reduce the error due to physical activity. If you are right-handed, slip the pressure cuff over your left arm and extent your left arm palm up. Whether sitting or lying. Be sure that your arm rests at the same level as your heart turn the cuff so that the stethoscope diaphragm (sound head ) is on the inside of the arm just above the elbow. This locates it over the large artery near the hollow of the elbow. ( this artery can be also found by feeling for the pulse of the artery ) Grasp the end of the cuff and pull it snug, then wrap it around and over your arm, pressing together with Velcro tape to bind the cuff securely.

2. Inflate the cuff

Feel the pulse of the artery with your fingertips to be sure the heads of the stethoscope is located directly over it. Insert the earpieces of the stethoscope ( adjust by turning earpieces to fit comfortably in your ears ) Hold the gauge in your left hand or clip onto the cuff on the loop provided for reading. Close the air-flow valve on the bulb ( turn lockwise ) DO NOT OVERTIGHTEN. Inflate the cuff by repeatedly squeezing the bulb with your right hand. Listen to the pulse beat whilst inflating the cuff. Watch the gauge. When you can no longer hear the pulse beat, raise the pressure an additional 30mm.

3. Slowly deflate the cuff

Slowly open the air-flow valve by turning counter clockwise that the pressure drops 2-4mmHg with each beat of your heart. ( This will usually mean a drop of one to two marks on the gauge ever second )

The rate of deflation is important for accurate reading. Remember, the pressure of the cuff has shut off all blood, flow to arm. So do not leave the inflated fully any longer than absolutely necessary.

4. Systolic pressure

After opening the air-flow valve listen carefully for a pulse beat. The moment you hear the faint rhythmic tapping or tumping sound of the pulse beat, note the reading on the gauge. This is your systolic (upper) blood pressure.

It may be different at first for you to detect the sounds of the pulse beat, listen carefully and acquaint yourself with these unfamiliar sounds. You should also notice the needle on the gauge “bounce”when your systolic pressure is reached.

5. Diastolic pressure

Allow the pressure to continue dropping at the same rate as before 2-4mmHg per second. Listen carefully with the stethoscope. The sounds you hear will change the phases. From the first sharp tapping or thud, they will soffen to blowing or swishing sound. Watch the falling needle. At the exact point when you can no longer hear the sounds, read the gauge. This is your diastolic (lower)blood pressure reading.

c. Mercury

Internal nominal diameter of the tube containing mercury is 3.5mm.

d. Maintenance

Under normal condition, the device is recommended to be calibrated every two years. Calibration should also be done after repair. Calibration should be carried out at point 50mmHg and 200mmHg.

 

1: double scale display, accurate measurement.

2: surface spray treatment, anti-corrosion, wear-resistant, beautiful.

3: add mercury resistant paper on top of the test tube to prevent mercury leakage from improper use.

BEAUTY & PERSONAL CARE

Trusted medical manual of neonatal aneroid blood pressure monitoring device from China supplier

Trusted medical manual of neonatal aneroid blood pressure monitoring device from China supplier

Trusted medical manual of neonatal aneroid blood pressure monitoring device from China supplier

Trusted medical manual of neonatal aneroid blood pressure monitoring device

No desirable products?
Sourcing assistant>
How to start your business
  • Step 1
    Find your interested products by search keywords
  • Step 2
    Contact the supplier by clicking ”Enquire” or “request meeting” button, otherwise, you also could consult our import consultant.
  • Step 3
    After verifying your email, get response from suppliers or our trade manager will contact you as soon as possible
  • Step 4
    Set up meeting with the Chinese supplier without language barrier
Send Enquiry
ToLily Liu
Meorient Import & Export Co.LTD
Enquire
Popular Searches
lathersbuchertether.thermosatherosfortherusherfinetherhb thermfortherthoraether.thermoslocherfletcher