Toxic gas detector HCL gas leak detector sensitive Hydrogen chloride transmitter
KQ500D-HCL Fixed gas detector (also called gas sensor or gas transmitter). Can continuousely detect the density of HCL. Standard 4~20mA two wires signal output. Sound and light alarm, can get into the DSC system directly.
Various kinds of gases detectors, high precision
Fixed explosion-proof shell, safe and reliable
4~20 mA electric current output, compatible with existing alarm unit or DCS ( distributed control system)
Imported sensor, sensitive, high precision, quick response, stable performance
Sipmple operation steps, easy to install and maintance
Detect and analyze gases concentrantion in remote places
KQ500D diagram
Detecting gas | Hydrogen chloride |
Measuring Range | 0-20PPM |
Resolution | 0.1PPM |
Deviation | ≤± 3% F.S |
Respond Time | T90 < 30 s |
Working Temperature | Toxic gas: - 20 °C ~ + 50 °C |
Combustible gas: - 40 °C ~ + 70 °C | |
Working Humidity | < 95% R.H. no condensation |
Sensor | electrochemical sensor; |
Sensor life | 2-5 year |
Working Voltage | 24V DC±15% |
Working Time | continuously as long as power input |
Protection Class | IP66 |
Weight | 1.5KG |
Size | 203mm*141mm*95mm |
Fixed parameter | Fixing type: wall-mounted type |
Transition cable: two core shield cable | |
(KQ500-EX uses three core shield cable), | |
Section 2×1.5mm2, external diameter 10mm | |
Transmission distance ≤1000m | |
Technical parameter | Working voltage: 24V DC±15% |
Working current: KQ500-EX is 120mA, others ≤50 mA | |
Output signal: 4~20mA standard signal two wire type output | |
(KQ500-EX three wire type) | |
Explosion-proof Level | Exd IICT6(used for explosion proofing detector); |
ExiaIICT4(used for intrinsic safety type detector) |
KQ500N and KQ500D gas alarm system
Installation case
FAQ
Q1. Can it applied to other gases?
A: KQ500D series can detect a wide range of gases, but one device is designed for one gas.
Q2.What certificate can you support?
A: Our products have passed CE, Calibration Cert, Confirmity Cert of Explosion-proof, Pattern Approval Cert of the Measuring Instrument.
Q3. How is the calibration be done?
A: To keep the high sensitivity, please calibrate it at least once a year .
Q4. What about the lead time?
A: We usually deliver the goods in 2-5 working days after the order confirmed.