Frequency inverter/vfd/AC Drive data sheet | ||||||||
Control mode | Control mode | SVC in open loop | V/F control | Close loop vector control* | ||||
Starting torque | 0.5Hz 180% | 0.5Hz 150% | 0.00Hz 180%* | |||||
Speed adjust range | 1:100 | 1:100 | 1:1000* | |||||
Speed stabilizing precision | ±0.02%* | |||||||
Torque precision | NO | NO | ±5% | |||||
Motor type | General induction motor, Permanent magnet synchronous motor (PMSM )* | |||||||
Function design | Highest frequency | General vector control :400Hz V/f control:4000Hz | ||||||
Frequency resolution | Digital setting: 0.01Hz analog setting:maximum×0.025% | |||||||
Carrier frequency | 0.5K~16KHz, the carrier frequency can be adjusted by temperature automatically | |||||||
Frequency reference setting method | Digital of Control panel, analog AI1, AI2, potentiometer of control panel, UP/DN control, communication, PLC pulse frequency | |||||||
Acceleration./deceleration characteristic | Linear curve and S curve accel. /decel. mode, range of time: 0.0 to 65000S. | |||||||
V/F curve | 3 mode: linear, multiple points, N Power | |||||||
V/F separation | 2 times separation: totally separation, half separation | |||||||
DC braking | DC braking frequency: 0.0 to 300Hz, DC braking current: 0.0% to 100% | |||||||
Braking unit | Standard built in for up to 4T22GB(22kw), optional built it for 4T37G~4T75G (18.5kw to 75kw), external built for above 4T93G (95kw). | |||||||
Jog function | JOB frequency range: 0.0 to 50.0Hz, the acceleration and deceleration time of Jog | |||||||
Configured PID function | Easy to perform pressure, flow, temperature close loop control. | |||||||
PLC multiple speed | To achieve 16 segment speed running through built in PLC or terminal control | |||||||
Common Dc bus | Multiple inverters use one DC bus for energy balance. | |||||||
Auto voltage regulation (AVR) | Enable to keep output voltage constant when grid fluctuation | |||||||
Over load tolerance capability | G type model: 150% rated current for 60s, 180% rated current for 3s, P type Model: 120% rated current for 60s, 150% rated current for 3s. | |||||||
Stall protection control when over current, over voltage | Carry out limiting automation for running current, voltage to prevent over current, over voltage frequently | |||||||
Rapid current limit function | Minimize the IGBT module broken to protect the AC inverter, maximum reduce the over current fault. | |||||||
Torque limit and torque control | "Excavator" characteristics , torque limit automatically during motor running. Torque control is available in close loop vector control mode. | |||||||
Features | Friendly interface | Display Hello when power on. | ||||||
Multiple function key JOG button | It can set for Forward Jog, reverse Jog, forward/reverse switch | |||||||
Timing control function | A total running time and total running time calculating | |||||||
2 group motor parameters | To achieve two motor switchover freely, control mode is selectable | |||||||
Motor over heat protection | Accepting motor temperature sensor signal input via AI1 terminals. | |||||||
Multiple kinds encoder * | Compatible collector PG, differential PG, and rotary transformer Encoder( resolver). | |||||||
Command source | Control panel, control terminals, series communication, switch freely. | |||||||
Frequency source | Digital setting, analog current/voltage, pulse setting, serial communication, main and auxiliary combination. | |||||||
Protection function | Short circuit detect when power on, input/output phase loss, over voltage, over current, under voltage, over heat, over load protection. | |||||||
Environment | Application site | Indoor, free of exposure to sunlight, no dusty, no corrosive, no inflammable gas, no oil and water vapor, and water dipping | ||||||
Altitude | Lower 1000m | |||||||
environment temperature | -10℃~+40℃, power derated for 40~50℃, rated current derated 1% for 1℃ increasing. | |||||||
humidity | Less than 95%, no water condense. |