Toky Multi Channel Input Smart AC And DC Volt Meter Panel Meter RS485 Current Ampere Metering 2 Loops Analog Digital Voltmeter
Model | Alarm | Analog | RS485 | DI input | Input range | Code |
DL8-IRC18V600 | 2 loops | 4~20mA | Yes | Yes | IN1:6V,IN2:60V,IN3:600V | B0490DL01 |
DL8-IRC18V200 | 2 loops | 4~20mA | Yes | Yes | IN1:2V,IN2:20V,IN3:200V | B0490DL01 |
DL8-IRC18V100 | 2 loops | 4~20mA | Yes | Yes | IN1:1V,IN2:10V,IN3:100V | B0490DL01 |
DL8-IRC18A2 | 2 loops | 4~20mA | Yes | Yes | IN1:2A,IN2:0.2A,IN3:0.02A | B0490DL01 |
DL8-IRC18AACT | 2 loops | 4~20mA | Yes | Yes | IN1:5A(AC) | B0490DL01 |
DL8-IRC18DACT | 2 loops | 4~20mA | Yes | Yes | IN1:75mV(DC) | B0490DL01 |
DL8-RC18V600 | 2 loops | No | Yes | Yes | IN1:6V,IN2:60V,IN3:600V | B0410DL01 |
DL8-RC18V200 | 2 loops | No | Yes | Yes | IN1:2V,IN2:20V,IN3:200V | B0410DL01 |
DL8-RC18V100 | 2 loops | No | Yes | Yes | IN1:1V,IN2:10V,IN3:100V | B0410DL01 |
DL8-RC18A2 | 2 loops | No | Yes | Yes | IN1:2A,IN2:0.2A,IN3:0.02A | B0410DL01 |
DL8-RC18AACT | 2 loops | No | Yes | Yes | IN1:5A(AC) | B0410DL01 |
DL8-RC18DACT | 2 loops | No | Yes | Yes | IN1:75mV(DC) | B0410DL01 |
DL8-IRC10V600 | 2 loops | 4~20mA | No | No | IN1:6V,IN2:60V,IN3:600V | B0370DL01 |
DL8-IRC10V200 | 2 loops | 4~20mA | No | No | IN1:2V,IN2:20V,IN3:200V | B0370DL01 |
DL8-IRC10V100 | 2 loops | 4~20mA | No | No | IN1:1V,IN2:10V,IN3:100V | B0370DL01 |
DL8-IRC10A2 | 2 loops | 4~20mA | No | No | IN1:2A,IN2:0.2A,IN3:0.02A | B0370DL01 |
DL8-IRC10AACT | 2 loops | 4~20mA | No | No | IN1:5A(AC) | B0370DL01 |
DL8-IRC10DACT | 2 loops | 4~20mA | No | No | IN1:75mV(DC) | B0370DL01 |
DL8-RC10V600 | 2 loops | No | No | No | IN1:6V,IN2:60V,IN3:600V | B0280DL01 |
DL8-RC10V200 | 2 loops | No | No | No | IN1:2V,IN2:20V,IN3:200V | B0280DL01 |
DL8-RC10V100 | 2 loops | No | No | No | IN1:1V,IN2:10V,IN3:100V | B0280DL01 |
DL8-RC10A2 | 2 loops | No | No | No | IN1:2A,IN2:0.2A,IN3:0.02A | B0280DL01 |
DL8-RC10AACT | 2 loops | No | No | No | IN1:5A(AC) | B0280DL01 |
DL8-RC10DACT | 2 loops | No | No | No | IN1:75mV(DC) | B0280DL01 |
DL8-IV600 | No | 4~20mA | No | No | IN1:6V,IN2:60V,IN3:600V | B0300DL01 |
DL8-IV200 | No | 4~20mA | No | No | IN1:2V,IN2:20V,IN3:200V | B0300DL01 |
DL8-IV100 | No | 4~20mA | No | No | IN1:1V,IN2:10V,IN3:100V | B0300DL01 |
DL8-IA2 | No | 4~20mA | No | No | IN1:2A,IN2:0.2A,IN3:0.02A | B0300DL01 |
DL8-IAACT | No | 4~20mA | No | No | IN1:5A(AC) | B0300DL01 |
DL8-IDACT | No | 4~20mA | No | No | IN1:75mV(DC) | B0300DL01 |
DL8-V600 | No | No | No | No | IN1:6V,IN2:60V,IN3:600V | B0215DL01 |
DL8-V200 | No | No | No | No | IN1:2V,IN2:20V,IN3:200V | B0215DL01 |
DL8-V100 | No | No | No | No | IN1:1V,IN2:10V,IN3:100V | B0215DL01 |
DL8-A2 | No | No | No | No | IN1:2A,IN2:0.2A,IN3:0.02A | B0215DL01 |
DL8-DACT | No | No | No | No | IN1:75mV(DC) | B0215DL01 |
Power supply | 100~240V AC/DC(85-265V) |
Measurement accuracy | (>2000)±0.5%F.S±3digits @ 25±3℃ Measuring temperature drift < 500PPM |
Resolution | Minimum unit display value of default range or 12bits |
AC Frequency |
AC measuring frequency range:45~400Hz measuring accuracy range: 50~100Hz |
Relay capacity | AC 250V /1A rated load life > 100000 times |
Power consumption | < 6VA |
Environment |
In door, temperature: 0~50℃ no condensation, humidity: <85%RH,altitude<2000m |
Storage environment | -10~60℃, no condensation |
Switching input | No power dry contact input Signal voltage≤DC 24V |
Current output | DC 4~20mA Load<500Ω Temperature drift 300PPM |
Communication | RS485 port Modbus-RTU procotol, can be connected up to max 30 units. |
Insulation resistance | Input, output, power VS meter cover >20MΩ |
ESD | IEC/EN61000-4-2 Contact ±4KV /Air ±8KV perf.Criteria B |
Pulse train anti-interference | IEC/EN61000-4-4 ±2KV perf.Criteria B |
Surge immunity | IEC/EN61000-4-5 ±2KV perf.Criteria B |
Voltage drop & short interruption immunity |
IEC/EN61000-4-29 0%~70% perf.Criteria B |
Isolation withstand voltage |
Signal input, output, power: 2000VAC 1min |
Weight | About 400g |
Cover material | The shell and panel frame PC/ABS (Flame Class UL94V-0) |
Panel material | PET(F150/F200) |
Power failure memory | 10 years, times of writing: 1 million times |
Panel Protection level | IP65 (IEC60529) |
Safety Standard | IEC61010-1 Overvoltage category Ⅱ,pollution level 2,levelⅡ(Enhanced insulation) |
FAQ
Q1.Can you produce according to the samples or drawings?
Yes, we can produce by your samples or technical drawings. We can build the molds and fixtures.
Q2.What is your terms of payment?
Usually,we accept T/T, irrevocable L/C at sight. For regular orders, Terms of payment 30% deposit, full payment before delivery the goods.
Q3.What is the lead time?
For standard models, lead time is about 3~5 days after order confirmed and payment received.
For OEM orders, the delivery is about 2~3 weeks after data confirmed and payment received.
Q4.What is your terms of packing?
Under TOKY brand, the standard packing is 1pc item in a colour box or brown inner box, then into standard export carton.
For OEM order, usually 1pc item in a brown inner box, then into standard export carton.
Q5.What is your terms of delivery?
We accept EXW,FOB,CIF,etc. You can choose the one which is the most convenient or cost effective for you.
Q6.How to solve the quality problems after sales?
Take photos or videos of the problems and send to us.
We will make a satisfied solution for you within 24 hours after we confirm the problems.
Q7.Do you have any MOQ limit for the order?
Low MOQ, 1pc for sample checking is available.
Q8.Is it OK to print my logo on the product?
Yes, OEM service is available.
Please confirm with our sales team formally before production and confirm the design firstly based on our sample.
Q9.Are you manufacturer or trading company?
We are manufacturer for over 30 years. Welcome to visit our factory at anytime.