TPS-GC128 gas chromatography with optional column oven and autosampler and FID TCD ECD FPD detector
  • TPS-GC128 gas chromatography with optional column oven and autosampler and FID TCD ECD FPD detector

TPS-GC128 gas chromatography with optional column oven and autosampler and FID TCD ECD FPD detector

FOB Reference Price
Purchase quantity ()
Minimum order quantity
Payment
Meorient Import & Export  Co.LTD
Meorient Import & Export Co.LTD
China - Hangzhou
Trading Company
Trade Capacity
Export Percentage
Nearest Port
Hangzhou,Shanghai
Accepted Delivery Terms
Employees
5-10人
Accepted Payment Currency
USD,CNY
Average Lead Time
45 Day(s)
Certifications
Product Specifications
--
Product Description
Overview
Quick Details
Warranty:
1 year
Customized support:
OEM, ODM
Place of Origin:
Shanghai, China
Brand Name:
Toposun
detector:
FID, TCD, ECD, FPD
FID Detection limit:
≤ 3 * 10-12g / s (n-hexadecane)
FID Baseline noise:
≤ 5 * 10-14 A
TCD sensitivity:
5000mV.ml / mg (n-hexadecane)
TCD baseline noise:
≤ 0.05 mV
ECD Radioactive source:
Ni63
ECD Detection limit:
≤ 8 * 10-14 g / ml (r666)
FPD Temperature range:
- 350 ℃
FPD Detection limit:
≤ 2 * 10 -12g / s (P) ≤4 * 10 -11g / s (S)
column oven volume:
22L
Certification:
CE
Supply Ability
Supply Ability:
100 Set/Sets per Month gas chromatograph
Packaging & Delivery
Product Description

Column oven:



● Inner volume: 22L



Temperature range: 5 ℃ - 400 ℃ at room temperature



● Temperature control accuracy: ± 0.1 ℃



● Heating rate: 0.1 - 60 ℃ / min



● The order of heating of the program: 9



● Program temperature repeatability: ≤ 2%



● cooling method: after opening the door + variable high-speed motor



● Cooling rate: ≤8 mins (250 ℃ - 50 ℃)







Heating area:



● In addition to the oven independent heating zone, there are 6 additional heating zones. 2 inlet heating zones, 2 detector heating zones, and 2 auxiliary heating zones.



● The maximum heating temperature of the auxiliary heating zone can reach 400 ℃







Sampler:



Temperature control range: room temperature 7 ℃ - 420 ℃



● Temperature control mode: independent temperature control



● Carrier gas flow control mode: constant voltage, constant current, constant line speed



● Number of simultaneous installations: up to 3



● Injection unit type: packed column, split / splitless



● Split ratio: Direct setting (shunt mode)



Stigma pressure range: 0 - 400kpa



● Stem pressure control accuracy: 0.1kpa



● Flow setting range: H20 - 200ml / min N20 - 200ml / min







Detector:



● Hydrogen flame ionization detector (FID):



Detection limit: ≤ 3 × 10-12g / s (n-hexadecane)



Baseline noise: ≤ 5 × 10-14 A



Baseline drift: ≤ 6 × 10-13 A



Dynamic range: 107



RSD: ≤ 3%



● Thermal conductivity detector (TCD)



Sensitivity: 5000mV.ml / mg (n-hexadecane)



Baseline noise: ≤ 0.05 mV



Baseline drift: ≤ 0.15 mV / 30 min



Dynamic range: 105



RSD: less than or equal to 3%



● Electronic Capture Detector (ECD)



Radioactive source: Ni63



Detection limit: ≤ 8 × 10-14 g / ml (r666)



Minimum detection: 80fg / s



Baseline noise: ≤ 0.1mV



Baseline drift: ≤ 0.3mV / 30min



Dynamic range: 103



Temperature range: room temperature 7 ℃ - 420 ℃



At the same time the number of installations: up to 2



Ignition function: automatic



● Flame photometric detector (FPD):



Temperature range: - 350 ℃



Detection limit: ≤ 2 × 10 -12g / s (P) ≤4 × 10 -11g / s (S) Sample: methyl parathion



Dynamic range: P 103



Dynamic range: S 102







Data Workstation:



● Standard instrument electrical phase analysis software for Windows XP / Windows 7, 32-bit application software



● data acquisition: a single analysis and batch analysis corresponding to the data file name automatically generated function, the user program startup function.



● Data processing analysis: Waveform processing function, data processing function Qualitative function (multi-relative retention time, component) Quantitative function (area percentage method, corrected area percentage method, internal standard method, external standard method, standard addition method, index calculation) Manual work curve making function, column performance calculation, data comparison function.



● Report: sample information, environment setting, chromatogram, peak table, graph, text and other, user can customize the layout, preview function.



● File: File management data browser, integrated file structure, file conversion function (AIAANDI form, text form), template function.



● Power supply voltage: 220V ± 22V, 50Hz ± 0.5Hz



● Power: 3000W


Detailed Images
TPS-GC128 gas chromatography with optional column oven and autosampler and FID TCD ECD FPD detector from China supplier
Packing & Delivery
No desirable products?
Sourcing assistant>
How to start your business
  • Step 1
    Find your interested products by search keywords
  • Step 2
    Contact the supplier by clicking ”Enquire” or “request meeting” button, otherwise, you also could consult our import consultant.
  • Step 3
    After verifying your email, get response from suppliers or our trade manager will contact you as soon as possible
  • Step 4
    Set up meeting with the Chinese supplier without language barrier
Send Enquiry
ToLily Liu
Meorient Import & Export Co.LTD
Enquire
Popular Searches
lathersbuchertether.thermosatherosfortherusherfinetherhb thermfortherthoraether.thermoslocherfletcher