Product Description
Overview
Quick Details
Warranty:
3 years
Classification:
Other
Brand Name:
TMAX
Model Number:
TMAX-VGB-6
Place of Origin:
CHN
Source voltage:
AC110V-240V, Customized
Gloves port:
DN215mm, Acid and alkali resistant material PPS
Control system:
6 inch color touch screen, SIEMENS
H2O concentration:
<1 ppm (20 °C, 1 atm) Touch screen
Oxygen concentration:
<1 ppm (20 °C, 1 atm) Touch screen
Organic solvent filter:
21L
Working gas:
N2,Ar,He
Certification:
CE
Supply Ability
Supply Ability:
1000 Set/Sets per Year
Packaging & Delivery
Product Description

 

 

Lab Research Single or Dual Chamber Vacuum Glove Box with Dry Gas Station Purification System (H2O&O2< 1ppm)

 

Featers
VGB-6 is a dual stainless steel glove box designed for researchers in material science, chemistry, semiconductor, and related topics. The purification cylinder is made of BASF antioxidant materials from Germany and UOP water adsorbent materials from the US in order to achieve a low water and oxygen concentration of lower than 1ppm, such that experiments can be conducted in an ultra clean and highly purified gas environment. It is integrated with vapor pressure control system, purity control system, automatic gas purity regeneration control system, auto alarm, and system data log recording.

Specifications 

 

Working Voltage

220V AC, 50/60Hz, Single Phase

Max. Power Consumption

3KW

Glove Box Chamber

·         Case Material: Stainless Steel 304

·         Dimensions: 2400mm(L) x 800mm(W) x 930mm(H)

·         12mm thick double layer laminated safety glass with corrosion protection film for operating in a safe and easy manner


Chamber Condition

·         Water concentration: <1 ppm (20°C, 1 atm)

·         Oxygen concentration: <1 ppm (20°C, 1 atm)

Leak rate

<0.05 Vol% / hr (Depending on oxygen concentration inside the glove box)


Air-lock Chamber

·         Antechamber Dimensions: 385mm(Dia.) x 588mm(L)

·         Small Chamber Dimensions (for tools): 150mm(Dia.) x 300mm(L)

·         Max. vacuum level: 100 Pa


Working Gas

·         Operating gas: Inert gas such as N2, Ar, He

·         Regenerating gas: Mixture of H2 (10%) and Operating gas 

o    For purification system with only water adsorbing function, Regenerating gas will be the same as Operating gas


Gas Purification System

·         Automated Regeneration Process

·         Automated water and oxygen removal

·         Purification Cylinder: made of BASF antioxidant materials and UOP water adsorbent materials

·         Moisture removal capacity: 1.5KG

·         Oxygen removal capacity: 180L


Filter System

·         Organic Solvent Filter System filled with replaceable activated carbon

·         Built in HEPA filter can eliminate particle size > 0.3μm

Control system

·         Siemens PLC control system with 6" touch screen display

o    Water concentration: 0 - 1000 ppm with an accuracy of 0.1 ppm

o    Oxygen concentration: 0 - 1000 ppm with an accuracy of 0.1 ppm

o    Pressure: -2500 to 2500 Pa with an accuracy of 1 Pa


Pump

·         England EDWARDS pump is included for faster vacuum and removing moisture

·         Vacuum rate: 8.4 - 12 m^3/hr

Blower

Flow Rate: 90m³/h

Purification Pipeline

304 Stainless Steel, KF40 Port

Gloves

A pair of NORTH butyl glove is included to provide better protection against toxic materials

Lighting

Built in fluorescent lamp


Slidable Shelf

·         Three slidable shelves are built 0n top of inside glove chamber with dimensions of 300mm x 250mm

·         300mm away from roof

Product Dimensions

3115mm(L) x 830mm(W) x 1830mm(H) (123" x 33" x 72")

Shipping Dimensions & Weight

Total 2 pallets

#1: 86"x41"x84"

#2: 86"x41"x83"

Total weight 1800 lb



Warranty

·         One Year limited warranty with lifetime support

·         Rusting and damage due to improper storage condition or maintenance is not covered by warranty

·         Gloves are consumable items and are not covered under warranty

Application Notes

·         The channel between the glove box chamber and the gas purification system must be unimpeded during the operation of gas purifying

·         Always check the joints, gloves, sealing elements, and pipelines for air-tightness before and during the operation

·         Corrosive gases are prohibited as they will damage the water sensor and oxygen sensor

·         The inlet and outlet of the Air-lock Chamber must not be opened at the same time to prevent contamination by the external gas

·         Coolant water outlet must remain switched on all the time

·         System check frequently to replace filters and solvent adsorbents for maintanence and maximum efficiency

 

Our Company & Team

 

Certifications
 TMAX Lab Research Single or Dual Chamber Vacuum Glove Box with Dry Gas Station Purification System (H2O&O2< 1ppm) from China supplier
Cooperative Partner

 TMAX Lab Research Single or Dual Chamber Vacuum Glove Box with Dry Gas Station Purification System (H2O&O2< 1ppm) from China supplier

Packaging & Shipping

PACKAGE:

     1 Standard exported package: Internal anticollision protection, external export wooden box packaging.

     2 Shipping by express, by air, by sea according to customers' requirements to find the most suitable way.

     3 Responsible for the damage during the shipping process, will change the damage part for you for free.

 

DELIVERY TIME:15-20 days after confirming order,detail delivery date should be decided according to production season and order quantity.

 TMAX Lab Research Single or Dual Chamber Vacuum Glove Box with Dry Gas Station Purification System (H2O&O2< 1ppm) from China supplier

 

No desirable products?
Sourcing assistant>
How to start your business
  • Step 1
    Find your interested products by search keywords
  • Step 2
    Contact the supplier by clicking ”Enquire” or “request meeting” button, otherwise, you also could consult our import consultant.
  • Step 3
    After verifying your email, get response from suppliers or our trade manager will contact you as soon as possible
  • Step 4
    Set up meeting with the Chinese supplier without language barrier
Send Enquiry
ToLily Liu
Meorient Import & Export Co.LTD
Enquire
Popular Searches
lathersbuchertether.thermosatherosfortherusherfinetherhb thermfortherthoraether.thermoslocherfletcher