Surgical endoscope fractional beauty CO2 lasers ENT surgical equipment
CO2 fractional laser machine
Laser type | fractional CO2 laser |
Wavelength | 10600nm |
Machine power | 60W |
Output power | ≤30W (optional) |
Operating voltage | AC 220V ± 10%, 50Hz |
Area of Focal spot | 0.05mm2 |
Wavelength of the target | 635 nm |
Conduct system | Seven-joints laser articulated arm |
Optical system | 7 articulated arms |
Laser indicator | 650nm ruby laser |
Power of Target optical | ≤ 5mw |
Diameter of Focal spot | 0.25mm |
Area of Focal spot | 0.05mm2 |
Graphic area | ≤ 20mm × 20mm |
Cooling system | Wind cooling system |
Warranty | 1 year |
1. Skin tightening , fractional skin resurfacing , Skin renewing, wrinkle removal, whitening , pore minimization.
2. Acne scar removal, scars and surgery scars, dermabrasion, Remove intractable chloasmas and pigmentation, etc.
3. CO2 laser cutting in aesthetic surgery: mainly used for cutting on blepharoplasty , skin tags and ingrown nails , compound nevus and intra dermal nevus ect.
1. CO2 Fractional laser is the most advanced conceptual fractional CO2 skin peeling laser system with a wavelength of 10600nm. In addition to its fine skin-peeling effect, it can effectively penetrate the laser beam into the dermis.
2. Laser machine has 2 kinds of operating system; one is fractional CO2 laser for scars removal, skin rejuvenation, stretch marks removal.
3. And another system is for vaginal rejuvenation. It has 2 probes. On the probe there is 2940 lens, so it is mixture of 10600nm & 2940nm light. This system only has 2 shapes: round & square.
1. USA coherent laser device
2. 10600 nm wavelength
3. 50 Watts max power
4. Ellipse scan, rectangle scan, triangle scan
5. 650nm ruby laser indicator
6. Wind cooling system
7. Compared with traditional fractional CO2 laser, this model has steady energy output and dramatic treatment results. What's more, you do not need to change the CO2 tube at all.
Scanner treatment | Power(w)0-30w | Duration(ms)0.1-10ms | Interval(ms)1-5000ms | Distance(mm)0.1-2.6mm | Scanning mode | Time(th)1-20th | Point energy(mj) fraction of coverage(%) | ||||||
Wrinkle removal | 12w-28w | 0.8-1.2ms | 1ms | 0.5-1.0mm | Sequential or random mode | 1 | 9.6mj-33.6mj 25%-50% | ||||||
A second scan is completed rest for 10 to 20 days, three times as a course of treatment. Usually 1-2 treatments wrinkle can be significantly improved. | |||||||||||||
Scar removal | 12w-28w | 0.8-1.2ms | 1ms | 0.5-1.0mm | Sequential or random mode | 1 | 9.6mj-33.6mj 25%-50% | ||||||
A second scan is completed rest for 10 to 20 days, three times as a course of treatment. Usually 1-2 treatments to basically eliminate the scars. | |||||||||||||
Vascular removal | 10w-25w | 0.8-1.2ms | 1ms | 0.5-1.0mm | Sequential or random mode | 1 | 8mj-30mj 25%-50% | ||||||
A second scan is completed rest for 10 to 20 days, three times as a course of treatment. Usually 1-2 treatments may be substantially removed. | |||||||||||||
Large pores | 10w-25w | 0.8-1.2ms | 1ms | 0.5-1.0mm | Sequential or random mode | 1 | 8mj-30mj 25%-50% | ||||||
A second scan is completed rest for 10 to 20 days, three times as a course of treatment. Usually 1-2 treatments to improve the appearance of the skin significantly. | |||||||||||||
Mole removal | 15w-30w | 0.8-1.2ms | 1ms | 0.5-1.0mm | Sequential or random mode | 1 | 12mj-36mj 25%-50% | ||||||