A1-Hybrid | ||||
Module | A1-Hybrid-7.6 | A1-Hybrid-8.6 | ||
PV | ||||
Max.PV input power [W] | 9120 | 10320 | ||
Nominal DC voltage [Vdc] | 360 | |||
Max.DC voltage [Vdc] | 600 | |||
System startup voltage [Vdc] | 150 | |||
System shutdown voltage [Vdc] | 80 | |||
Operating voltage range [Vdc] | 105-500 | |||
Max.PV input current [A] | 10/ per MPPT | |||
Max.input short circuit cuttent [A] | 12.5 | |||
No of MPPT / Strings per MPPT | 3/1 | 4/1 | ||
Max.backfeed current | 39 Arms/ 2ms | |||
GRID-OUTPUT | ||||
Nominal AC output power [VA] | 7600 | 8600 | ||
Max. AC output power [VA] | 8360 | 9460 | ||
Nominal AC output voltage (Range) [Vac] | 120 / 240 Vac split phase (211 Vac- 264 Vac) | |||
Max.AC output current [A] | 35 | 41 | ||
Operating AC frequency range [Hz] | 59.3-60.5 | |||
Output power factor rating | Default>0.99 (Adjustable +/- 0.8) | |||
Total harmonic distortion [%] | <3 | |||
Max. AC output fault current and duration | 765 Apeak /5ms, 46Arms/cycle | |||
GRID-INTPUT | ||||
Max.AC input power [VAI | 8300 | 9460 | ||
Nominal AC input voltage [Vac] | 120 / 240 Vac split phase | |||
Nominal AC input frequency [Hz] | 60 | |||
Max.AC input current [A] | 35 | 41 | ||
BACKUP LOAD OUTPUT (with auto-transformer) | ||||
Max.continous AC output power [VA] | 7600 | 8600 | ||
Nominal AC output voltage (Range) [Vac] | 120 / 240 Vac split phase (211 Vac- 264 Vac) | |||
Max.continous AC output current [A] | 32 | 36 | ||
Nominal AC output frequency |Hz] | 60 | |||
Max. AC output fault current and duration | 200 Apeak /10ms. 34Arms/cycle | |||
BATTERY | ||||
Battery type | Li-ion | |||
Nominal DC voltage [Vdc] | 360 | |||
DC operating voltage range |Vdc] | 84-432 | |||
Max.DC charge and discharge current [A] | 25 | |||
Max. charge power (grid input only) [W1 | 7100 | 8000 | ||
Max. charge power (pv input only) [W] | 7600 | 8600 | ||
Max. discharge power [W] | 9000 | 10200 | ||
BMS communication interface | CAN2.0 | |||
EFFICIENCY | ||||
Max PV-AC [%] | 96.7 | |||
Max Battery-AC [%] | 96.46 | |||
CEC efficiency (PV-AC) [%1 | 95.67 | 95.75 | ||
PROTECTION | ||||
DC disconnect device | Yes | |||
Over voltage protection type | Varistor | |||
PV array ground fault detection | Pre-start RISO | |||
Ground fault monitoring | Yes | |||
Grid monitoring | Yes | |||
AC short circuit protection | Yes | |||
ALL-pole sensitive residual current monitoring unit(RCMU) | Yes | |||
Arc fault circuit interrupter(AFCI) | Yes | |||
Protection class/over voltage category | 1/IV | |||
GENERAL | ||||
Dimension(L*W*D) [mm] | 913*560*276 | |||
Package dimension(L*W*D) [mm] | 1016*667*397 | |||
Weight [kg] | 59 | |||
Package weight [kg] | 63 | |||
Enclosure rating | Type4X | |||
Operation temperature range[°Cl | -20 to +60 (-4°f to +140°f), no derating below 45 (+113°f) | |||
Storage temperature range[°C] | -30 ~+75 (-22°f to +167°f) | |||
Relative humidity [%] | 0-100 RH Condensing | |||
Typical noise emission [dB] | <35 | |||
Max. operation altitude without derating [m] | 2000 | |||
Self-consumption in standby mode [W] | <20 | |||
Topology | Transformerless | |||
Cooling concept | Natural convection | |||
HMI | ||||
Display | Backlight LCD, 3 LEDs | |||
Touch button | 4 | |||
Communication interface | RS485/LAN/WIFI(optional)/4G (optional) | |||
Communication protocol | Modbus/Sunspec. RTU | |||
Firmare update | Local USB/Remote web | |||
Meter | RS485 | |||
Warranty [years] | 5/10 (optional) |