Smart electric striker rfid card contactless smart hotel door lock
What's the Production introduction?
1. Weight | 4kgs |
2., Size | 290mm*60mm*34mm |
3. Static Load | <10Ua |
4. Working Load | 100Ma-150Ma |
5. Humidity | 20%-90% |
6. Working temperature | -50~60 degrees |
7. material | Stainless steel 304, moisture proof, fire retardant |
8. color | Brushed stainless steel color with PVD coating lasting more than10 years |
9. mortise | ANSI Standard mortise |
10. Inside Dead Bolt | Inside handle retracts latches and deadbolt |
11. card type | RFID,compatible with RFID Energy Saver |
12. Override Computer Key | individual/master cylinder for Emergency use |
13. Lock operation records | 240 PCS or more |
14. Power | DC6V or 4PCS#AA Alkaline batteries.18 months' duration |
15.LowBattery Voltage warning | Lower than 3.5 V |
16. PMS interface | Fidelio registered! |
17. Certificate | CE&FCC&ISO9 |
What's the configuration Orbita smart card contactless hotel door lock system?
How ORBITA hotel smart card door lock system works?
Our hotel smart card door lock systems consists of following:
-Hotel card door lock (Installed on the hotel room door)
-PC(usually located on the reception desk of hotel )
-Hotel card door lock management software(Download to PC,setting the software system )
-Encoder (Connect to PC,Issue the cards)
-Cards (Open doors)
How to gain the lock management software and how to install it to the computer?
When you order orbita hotel room card lock system ,we will send you orbita software CD for free.
To avoid permission issues, install Orbita Locking System 5.0 from CD to C:\programfiles\Orbita Locking System by default.This system requires Windows XP, Windows Vista SP1, Windows 7 or Windows 8 or higher version. 64bit is supported. If you are using Windows 7 or Windows 8, install/run the program as Administrator.
What's the encoder and how to use?
When you see this interface after installation, connect the encoder with the computer through USB port in the meanwhile
Enter the default Staff No. 001 and Password 001, press OK to log in. A message about the connection status of the encoder Reminder: Connection with Encoder Succeed means the system installation succeeds.
If there is more than one computer in front desk, you can share the database folder by LAN. Then all computers will share one database. See below:
How about the card key and what's the functions?
Open-door Cards | Guest Card | Maximum of 8 doors (including common ones and those of a suite room) of the same floor can be set per card. Supports blacklist. |
Master Card | Can open every door of the same locking system, including those deadbolted. Same function can be found in the PP. (5. open doors). For this reason the master card and/or PP MUST BE SECURED when not in use. | |
Emergency Card | Functions as the master card and meanwhile sets off alarm which can be canceled by any other open-door cards or a PP using its open doors function. For this reason the emergency card MUST BE SECURED when not in use. | |
Maintenance Card | Can open a specific lock within a period of time or a few times. | |
Building Card | Can open all doors of the same building within a period of time. | |
Floor Card | Can open all doors of the same floor within a period of time. | |
Group Card | Can open all doors of the same group within a period of time. Supports up to 8 groups. | |
Other Cards | Clock Card | Sets the time of lock’s inbuilt clock. Same function can be found in the PP. (6. settings → 1. clock set). It is recommended that you set time by using the PP when dealing with more than one lock, because the time in the card remains still while that in the PP keeps going on. |
Data Card (S70 Type) | A lock contains an audit trail of the last 210 openings (at most). To collect and view the audit trail you must use a data card or the READ OPENINGS function of or the PP. | |
Blocking Card | Access to every door of the same locking system can be blocked by this card and can be regained only by a PP, a master card or an emergency card, and the status of a blocked lock can be changed into unblocked by a blocking card only. For this reason the blocking card MUST BE SECURED when not in use. |
Do you have portable programmer to make operation more convenient?
Yes ,we do have.
What will indicate when operate wrong and how to solve?
Problem | Possible Reason | Solution |
Red light blinks two times and two beeps. | a) The card is not issued for this door. b) The staff/maintenance card has lost its validity after being used for a few times. | Use the correct card; Or issue a new maintenance card |
Red light blinks three times and three beeps. | The time of the card does not match that of the lock. | Synchronize the time either/both of the card or/and the lock. |
Red light blinks four times and four beeps. | The lock has not been authorized. | Authorize the lock with a card or a PP. |
Red light blinks five times and five beeps. | The card has been suspended. | Issue a new card. |
Red light blinks six times and six beeps. | The lock has been deadbolted. | If need be, gain access to the room with a master card, an emergency card or a PP. |
Red light blinks seven times and seven beeps. | The lock has been blocked by a block card. | If need be, gain access to the room with a master card, an emergency card or a PP, or unblock the lock with the lock card. |
Red light blinks eight times and eight beeps. | The lock has been authorized by another system. | Use cards issued by that system; Or perform mandatory authorization if need be. |
Where can be used of the smart card contactless system?
Do you have other hotel intelligent products?
Yes
What do we produce? |
|
1.Hotel M1 S50 card lock with management system |
|
2. Hotel Lock Cards: M1 S70, IC, Temic, M1 S50, Magnetic card. |
|
3. Door Controller,Hotel lift/elevator controlling system, Record-Reader (POS),Hotel didital safe ,Touch screen switch, |
|
4. ,Hotel minibar,hotel telephone,bathroom phone, door stopper,door closer....
|
|
What about your factory?
Company introduction:
Founded in 2004, ORBITA was established to manufacture innovative products to overseas market. Until now, ORBITA products have been used in more than 5,000 hotels ranging from 3 to 5 star covering 100 countries and most of the hotelchains.Varies tests have been conducted to ensure the quality of the products and certificates includes ISO,BHMA,CE,FCC,SASO,SONCAP etc.
The 46000 square meter garden factories with complete facility for hotel card locks, in room safe, switches and other hotel accessories enable ORBITA the biggest productivity in the industry in China.
What's your advantage?
Key capability
&. Biggest & Professional hotel lock, safe ,mini-bar factory made in China with best facility.
&. Experienced R&D and QC team.
&. Overseas Orientated with complete English Speaking sales and local service team.
&. Big Production Capacity: 100,000 pcs/month
Main Advantage of ORBITA
* Professional Manufacturer, biggest in hotel lock industry made in China.
* American Military standard Quality Control.10000 world wide references.
* OEM experience for leading hotel card keyless door lock company in the world.
* Biggest Market share in South East Asia Market.
* Complete range of Hi-Tech hotel in room electronic products.
* 18 month years warrantee for all ORBITA products.
FAQ:
1. Will your lock panel and handle rust?
Our stainless steel model will never rust since the material is 304 stainless steel. And the golden color lock is PVD coated which last quite a long time then normal coating technology.
2. What is the difference between American lock and Eu lock?
The main difference is the mortise. American lock use 5 latch ansi type mortise while European lock uses 2 or 3 latch mortise. However, European mortise is thinner and can be installed on those thin doors. American locks fit the thick doors( more than 35mm) better.
3. What is the minimum width of the door frame?
We have different lock models catering to different lock frame width. For standard ansi type(American) traditional mortise, the minimum width of the door frame is 110mm. For our ansi type small mortise, the frame can be 100mm. If the frame width is narrow then 100mm, suggest to use European standard mortise. Like our model E3061.
4. What is the minimum thickness of the door?
Our product range covering door thickness from 25mm to 80mm.If door thickness is less than 32mm, suggest to use our European standard lock.
5. What will happen if a guest loses his room card?
If a guest card is lost, we can simply issue a new guest card to the guest. To make sure the lost card is not used on the door, we can block the lost card when you issue the new card in the system simply by marking “suspend the previous card” option.
6. Does the lock have a record?
Yes, all locks have records inside. Each lock can keep 250 pcs records
7. Can you connect your system to PMS system?
Yes. Generally, all the software can be connected to each other.Either PMS system supplier or we can make a bridge software to connect the two.
For some famous PMS brand such as Fidelio Operator, we have existing bridge software in Fidelio database.
8. Can you offer online lock system?
We don't have online lock system based on 485 network. But our stand alone lock can realize 95% of the online lock function except on line data download, online programming, online lock status monitoring. The cost of each online lock is about 5 time more than a stand alone lock.
9. If we re-install the software, do we have to program the locks again?
Software re-installation should be done by professionals only as any mistake during re-installation can lead to serious problems. Usually, locks do not need reprogramming after correct re-installation of the software.
10. What maintenance shall we do with the locks?
Usually, in the first year, no need to do any maintenance with the locks, after the first year, you may need to change the battery, lubricate the latches, handles etc. If you find the deadbolt is not so smooth or bend, better to check it. Change the damaged part in time to avoid locking problems.
Please send your inquiry Details in the Below for MORE INFORMATION,thank you!