Single phase online ups 5kva 6kva 10kva for cctv
Rack Series 1-10KVA UPS double conversion pure online architecture, the structure can block abnormal power supply impact on the load, at the same time, it can ensure the stable and reliable output, and make the load run safely. It is the best architecture design that can effectively solve all power problems, the use of digital control technology to provide users with more secure power protection.
Feature:
1.Double conversion online design, output zero conversion time.
2.Adopt DSP digital control, excellent performance indicators, make the control system more steady and reliable.
3.Ultra-wide input voltage range.
4.Input frequency range is 40~70Hz, ensure stable operation when connected to various fuel generators.
5.With LCD+LED real-time display, users can intuitively understand the UPS operating status.
6.With self-diagnosis function, it can detect hidden faults of UPS in time.
7. N+1 parallel redundant design, can realize 3 parallel connections, greatly improved system reliability
Model |
H1KR |
H1KRS |
H2KR |
H2KRS |
H3KR |
H3KRS |
H6KR |
H6KRS |
H10KR |
H10KRS | |
Rated Power | 1KVA/0.9KW | 2KVA/1.8KW | 3KVA/2.7KW | 6KVA/4.8KW | 10KVA/8KW | ||||||
Input | Voltage | (110 ~ 300)VAC | (176 ~ 276)VAC | ||||||||
Frequency | (40 ~ 70)Hz | (46 ~ 54/56 ~ 64)Hz | |||||||||
Power Factor | >0.99 | ||||||||||
Battery | External battery Standard Voltage | — | 36VDC | 72VDC | 96VDC | 192VDC | |||||
Battery Type | Maintenance-free lead-acid battery | ||||||||||
Battery Number | 3PCS | — | |||||||||
Output | Voltage | 220(1±1% )VAC | |||||||||
Frequency | Synchronize with Input (Utility Mode) | ||||||||||
50(1±0.2%)Hz ( Battery Mode ) | |||||||||||
Overload Capacity |
100%-110%:Only warning sound; 110%-130%:Automatically turns off after 1 minute, or switches to bypass mode when the input is normal; >130%:Turn off immediately, or switch to bypass mode when the input is normal. | 105%-125%:Automatically turns off after 1 minute, or switches to bypass mode when the input is normal; 125%-135%,30 seconds or switch to bypass mode when the input is normal; >135%,Turn off after 0.5 seconds or switch to bypass mode when the input is normal | |||||||||
Output waveform | Pure Sine Wave | ||||||||||
Socket | Universal Socket | Terminal Block | |||||||||
Connection | RS-232 | Intelligent monitoring functions such as Utility abnormal, power outage, battery capacity, and UPS status indication. | |||||||||
Option | SNMP card, AS400 card, USB connection | ||||||||||
Surroundings | Temperature | 0℃~ 40℃ | |||||||||
Humidity | 20%~ 90% | ||||||||||
Audible Noise | <55dB | ||||||||||
Shape parameter | Host size (W×D×H)mm |
482.6x450x88 |
482.6x600x130 | ||||||||
Battery size (W×D×H)mm |
482.6x450x88 |
482.6x600x130 | |||||||||
Net Weight kg | 16.3 | 9.1 | 10.3 | 11.5 | 11.2 | 12.3 | 18.3 | 18.5 | 19.2 | 19.5 |
Q1: How to choose a right UPS?
A1:Tell us your demand, then our sales will recommend a suitable UPS to you.
Q2: What's the different between offline ups and line interactive ups?
A2: The true LINE INTERACTIVE design is in fact a combination of OFFLINE & ONLINE, in which the inverter plays a dual role of charging the battery when mains supply is present as well as regulating the output voltage and working as a normal inverter in absence of mains supply, so to the user it appears like an ONLINE System. Line Interactive UPS offers enhanced power protection over the basic Offline designs by providing additional line conditioning.
Q3: How about the delivery time?
A3: 7 days for sample; 25 days for bulk order.
Q4: What is the warranty of UPS?
A4: One year warranty on Must-UPS product.
Q5: How to solve the technical problem?
A5: 24 hours after-service consultancy just for you and to make your problem to solve easily.