Single phase high frequency online ups 1kva 2kva 3kva ups without battery for IT applications
Main Features
True double-version online UPS
DSP technology guarantees high performance
Output power factor 0.8
Standard backup UPS and long backup UPS in one intergrated unit
Adujstable battery number from 16pcs to 20pcs
Adjustable charging current via software(0.5A-0.6A)
Wide put voltage range(110VAC-300VAC)
Active iput power factor correction 0.99
50Hz/60Hz frequency converter mode
Emergency power off function
3-stage extendable charging design for optimized battery performance
Maintenance bypass available
SNMP/USB/RS-232 communication
Technical Specification
MODEL | HP1101B/H | HP1102B/H | HP1103B/H | HP1106B(H) | HP1110B(H) |
PHASE | Single phase with group | 1 phase in/1 phase out | |||
CAPACITY | 1000VA/800W | 2000VA/1600W | 3000VA/2400W | 6000VA/4800W | 10000VA/8000W |
INPUT | |||||
Voltage Range | 110-300VAC(auto sensing) | ||||
Low Line Transfer | 110VAC ±3% at 50% load 176VAC ±3% at 100% load | ||||
Low Line Comeback | 120VAC ±3% at 50% load 186VAC ±3% at 100% load | ||||
High Line Loss | 300VAC ±3% | ||||
High Line Comeback | 290VAC ±3% | ||||
Frequency Range | 45Hz-55Hz or 56Hz-65Hz | ||||
Power Factor | 0.99@100% load | ||||
OUTPUT | |||||
Output Voltage | 208/220/230/240VAC | ||||
AC voltage Regulation | ±1% | ||||
Frequency Range(Synchronized Range) | 48-52 Hz or 58-62 Hz | 46-54 Hz @50Hz system;56-64 Hz @60Hz system | |||
Frenquency Range(Batt. Mode) | 50Hz ±0.2 Hz or 60Hz ±0.2Hz | 50Hz ±0.1 Hz or 60Hz ±0.1Hz | |||
Current Crest Ratio | 1/3 | ||||
Harmonics Distortion | <3% THD(Linear load), <6% THD(Non-linear load) | ||||
Transfer Time | |||||
Bypass to Inverter(Line Mode) | 0ms | ||||
Inverter to Bypass(Line Mode) | 0ms | ||||
Waveform(Batt Mode) | Pure Sine Wave | ||||
EFFICIENCY | |||||
STANDARD MODEL | |||||
Battery Type | 12V/9Ah | 12V/9Ah | 12V/9Ah | 12V/7Ah | 12V/9Ah |
Numbers | 2pcs | 4pcs | 6pcs | 16pcs | 16pcs |
Typical Recharge Time | 5 hours recover to 90% capacity | 9 hours recover to 90% capacity | |||
Charging Current | 1.0A(Max) | 1.0A ±10%(default), 2.0A ±10%(Max) | |||
Float Charging Voltage | 218.4 VDC ±1% | ||||
LONG-RUN MODEL | |||||
Battery Type | Depending on applications | ||||
Numbers | Adjustable | ||||
Charging Current | 4A or 8A | 4.0A ±10%(default), 8.0A ±10%(Max) | |||
Float Charging Voltage | 218.4 VDC ±1%(Based on 16pcs batteries) | ||||
INDICATORS | |||||
LED Panel | UPS Status, Load Level, Battery Level, and Fault Conditions | ||||
ALARM | |||||
Battery Mode | Sounding every 4 seconds | ||||
Low Battery | Sounding every second | ||||
Overload | Sounding twice every second | ||||
Fault | Continously sounding | ||||
PHYSICAL | |||||
STANDARD MODEL | |||||
Dimension, D X W X H(mm) | 146 X 360 X 227 | 193 X 400 X 327 | 193 X 400 X 327 | 530 X 250 X 608 | 530 X 250 X 608 |
Net Weights(kgs) | 10 | 18 | 24 | 57 | 65 |
LONG-RUN MODEL | |||||
Dimension, D X W X H(mm) | 146 X 360 X 227 | 193 X 400 X 327 | 193 X 400 X 327 | 515 X 245 X 455 | 515 X 245 X 455 |
Net Weights(kgs) | 6 | 9 | 9.5 | 18 | 20 |
ENVIRONMENT | |||||
Operation Humidity | 0-95% RH@ 0-40℃(non-condensing) | ||||
Nosie Level | Less than 55dBA @ 1 Meter | ||||
MANAGEMENT | |||||
Smart RS-232 | Support Windows 2000/2003/XP/7, Unix and Mac | ||||
Optional SNMP | Power management from SNMP manager and web browser |
Product Images
Show you our factory
What certifications do we have?
Applications
How to choose the right UPS?
1. Understand specifications of all UPS.
2. Consider the requirements of power quality.
3. Understand the current capacity of UPS and consider the future expansion.
4. Choose reputed brands and manufacturers.
5. Choose UPS based on your requirements.
What are the important items you should evaluate when buying a UPS?
1. UPS reliability and stability.
2. The excellent engineers and the ability of products creation.
3. High efficiency and low noise.
What is the impact of different output waveforms?
There are three major types of loads, Resistive load (Lamps), SPS load (PC power supply) & Conductive
Load (Motors). All the types of load can be used with Pure Sinewave. However, only Resistive and SPS loads can be used with Modified Sinewave.