Project | Specifications | ||||
Power input | Rated input voltage (V) | 1-Phase 220V (-15%~+20%) 3-phase 380 V (-15%~+30%) | |||
Rated input current (A) | See table 2-1 | ||||
Rated input frequency (Hz) | 50Hz/60Hz,tolerance±5% | ||||
Power output | Applicable motor (kW) | See table 2-1 | |||
Rated output current (A) | See table 2-1 | ||||
The maximum output voltage (V) | 0~rated input voltage, error<±3% | ||||
The maximum output frequency (Hz) | 0.00~600.00 Hz,unit0.01Hz | ||||
Control characteristics | V/f patterns | V/f control Sensor-less vector control 1 Sensor-less vector control 2 | |||
Speed range | 1:50 (V/f control) 1:100 (sensor-less vector control 1) 1:200 (sensor-less vector control 2) | ||||
Speed accuracy | ±0.5% (V/f control) ±0.2% (sensor-less vector control 1、2 ) | ||||
Speed fluctuation | ±0.3% (sensor-less vector control 1、2 ) | ||||
Torque response | < 10ms (sensor-less vector control 1、2 ) | ||||
Starting torque | 0.5Hz: 180% (V/f control, sensor-less vector control 1) 0.25Hz:180%(sensor-less vector control 2) | ||||
Basic functions | Carrier frequency | 0.7kHz~16kHz | |||
Overload capability | G Model:150% Rated Current 60s,180% Rated Current 10s,200% Rated Current 1s. | ||||
Torque boost | Automatic torque boost;Manual torque boost 0.1%~30.0% | ||||
V/F Curve | Three ways: Three ways: straight; multi-point type; N Th-type V / F curve(1.2 Th -type、1.4 Th -type、1.6 Th -type、1.8Th -type、2Th -type) | ||||
Acceleration and deceleration Curve | Line or curve acceleration and deceleration mode. Four kinds of acceleration and deceleration time,Ramp Time Range :0.0~6000.0s | ||||
DC brake | DC brake start frequency: 0.00~600.00Hz DC brake time:0.0s~10.0s DC brake current:0.0%~150.0% | ||||
Basic functions | Jog brake | Jog frequency range:0.00Hz~50.00Hz. Jog deceleration time: 0.0s~6000.0s. | |||
Simple PLC、Multi-speed | Through the built-in PLC or control terminal to achieve up to 16 speed running | ||||
Built-in PID | Facilitate the realization of process control loop control system | ||||
Automatic voltage adjustment(AVR) | When the grid voltage changes, can automatically maintain a constant output voltage | ||||
Fast current limit function | Minimize over current fault protection inverter running | ||||
Over voltage Over current | System automatically limits of current and voltage during operation to prevent frequent | ||||
Run | Command source | Given the control panel, control terminal, serial communication port given. | |||
Frequency given | 9 kinds of frequency sources: digital setting, keyboard potentiometer setting, analog Voltage, given analog current reference pulse is given, the serial port is given, multi-speed given, PLC is given, the process PI D reference. There are several ways to switch | ||||
Protection function | Provide fault protection dozen: Overcurrent、Overvoltage、Undervoltage、Overtemperature、Overload Etc Protection. | ||||
Display and keyboard | LED Display | Display Parameters | |||
Key lock and function selection | Realize some or all of the keys locked, scope definition section keys to prevent misuse | ||||
Run and stop monitoring information | In the run or stop can be set to monitor U00 group four objects were. | ||||
Environment | Place of operation | Indoors, no direct sunlight, free from dust, corrosive gases, flammable gases, oil mist, water vapor, water drop and salt, etc. | |||
Altitude | 0~2000m De-rate 1% for every 100m when the altitude is above 1000 meters | ||||
Ambient temperature | -10℃~40℃ | ||||
Relative humidity | 5~95%, no condensation | ||||
Vibration | Less than 5.9m/s2 (0.6g) | ||||
Storage temperature | -20℃~+70℃ | ||||
Others | Efficiency | Rated power≥93% | |||
Installation | Wall-mounted or DIN-rail mounting | ||||
IP grade | IP20 | ||||
Cooling method | Fan cooled |