Measuring range | 50mm ~ 500mm | 50mm ~ 1000mm | |||||||||
Dead zone | 0mm ~ 50mm | 0mm ~ 50mm | |||||||||
Response time | About 50ms | About 100ms | |||||||||
Switch frequency | About 8Hz | About 3Hz | |||||||||
Resolution | 0.13mm (max) | 0.35mm (max) | |||||||||
Beam angle | 7 ° | 10 ~ 15 ° | |||||||||
Repeat accuracy | 0.3% | 0.3% | |||||||||
Range setting | Adjustable furthest and closest ranges. Adjust by + U-U | ||||||||||
Operating Voltage | 10 ~ 30V 15 ~ 30V (analog output 0 ~ 10V) | ||||||||||
Power consumption | 20ma | ||||||||||
Minimum load | Current output: <500Q Voltage output:> 5KQ | ||||||||||
Temperature drift | <5% (built-in temperature compensation) | ||||||||||
Protect the circuit | Anti-reverse protection, transient over-voltage protection | ||||||||||
Electromagnetic Compatibility | GB / T17626.2-2006 / GB / T17626.4-2008 | ||||||||||
Linear error | 1% | ||||||||||
Operating temperature | -25 ° C ~ + 70 ° C | ||||||||||
Housing material | Copper nickel plating | ||||||||||
Protection class | IP67 | ||||||||||
Connection | M12 aviation plug, 4 or 5 pin | ||||||||||
Size | L75mm (45mm length needs to be customized) Φ18mm | ||||||||||
Signal output | Analog output: 4~20mA, 0~10V Digital output: RS485 (Modbus RTU) Relay output: PNP, NPN, 2-route PNP, 2-rout NPN |