R-EGD portable radiation detector using the Geiger counter as a GM detector, fast response, and compared to similar instruments, the instrument has a wider range of dose rate measurement. In addition to the instrument can measure high-energy, low-energy γ-rays, but also for low-energy X-rays for accurate measurements with good energy response. Further analysis can be read by matching Chi Yuan dose rate data storage management software. For measuring exposure, dose equivalent rate, dose rates of intelligent detection equipment, in addition to measuring high-energy, low-energy γ-rays, but also for low-energy X-rays for accurate measurements. It can be widely used in environmental monitoring, health and epidemic prevention, import and export commodity inspection, radiation medicine, building materials, petrochemicals, geological survey, scrap iron and steel, nuclear laboratories and other areas of radiological protection monitoring, as well as airports, railway stations, ports and other areas of radioactive security.
Features:
1. High sensitivity, wide measuring range, good energy response;
2. High-speed micro-power microprocessor unit;
3. Digital display dose rate status;
4. Full Chinese menu-driven user interface;
5. Digital LCD display, the highlight backlight;
6. Built 1000 group dose rate stored data can be viewed at any time, power is not lost;
7. Reserved probe interface can join;
8. Dose rate, total dose can be measured and displayed;
9. You can customize the set dose rate threshold alarm;
10. Blocking alarm;
11. Probe failure alarm;
12. Battery charge time display function, undervoltage alarm function;
13. Radioactive point source tracking;
14. Alarm history viewing.
Technical Parameters:
• Detector: Geiger G-M counter
• Measuring range: dose rate: 0.01μSv/h - 0.2Sv/h
• Cumulative dose: 0.00μSv - 9.99Sv
• Accuracy: 0.01 - 0.2Sv/h≤±15%
• Energy response: ≤±30% (48Kev - 3.0Mev, 137Cs)
• Energy range: 35Kev - 3.0Mev
• Relative deviation: ≤±15% (137Cs) Sensitivity: 80CPS/μSv/h (relative to 60Co)
• Angular response: The instrument does not exceed 25% of the response in the calibration direction at 0° to 90°.
• Alarm threshold: 2.5mSv/h, 25mSv/h, 200mSv/h or set their own
• Alarm sound intensity: >80dB (50cm within)
• Display unit: dose rate: μSv/h, μGy/h, the cumulative dose: μSv
• Power: 3.7V lithium battery
• Voltage indication: when the battery voltage falls below 2V, instructions to replace the battery
• Power: Whole consumption ≤120mW (excluding display backlight power consumption)
• Weight: 700.0g (including battery)
• Size: 35*100*204 (mm)