key features
1.GS Series AC/Solar charging off grid hybrid inverter.
2. LED/LCD display, Enhanced functions setting via LCD, Man-machine intelligent design.
3. Built-in 40A/60A optional MPPT solar charger controller.
4. LCD shows the solar capacity.
5. 5 stages adjustable AC charging current. AC charging also can be closed.
6. AC/DC priority modes can be set.
7. Generator restart signal. (Dry contact)
8. 3 times peak power. Strong loading capacity.
9. Overload, output short-circuit protection
Product specifiction
MODEL (GS Series) | HV/LV Model | |||||||||
HV Model(4-10KW) LV Model(4-6KW) | ||||||||||
Line Mode Specifications: | ||||||||||
Input Voltage | Input Voltage Waveform | Sinusoidal (utility or generator) | ||||||||
Nominal Input Voltage | LV 120Vac | HV 230Vac | ||||||||
Low Line Disconnect | Normal:85Vac±4% Wide:80Vac±4% | Normal:184Vac±4% Wide:135Vac±4% | ||||||||
Low Line Re-connect | Normal:95Vac±4% Wide:85Vac±4% | Normal:194Vac±4% Wide:145Vac±4% | ||||||||
High Line Disconnect | Normal:136Vac±4% Wide:140Vac±4% | Normal:263Vac±4% Wide:263Vac±4% | ||||||||
High Line Re-connect | Normal:131Vac±4% Wide:135Vac±4% | Normal:253Vac±4% Wide:253Vac±4% | ||||||||
Max AC Input Voltage | 150Vrms | 270Vrms | ||||||||
Input Frequency | Nominal Input Frequency | 50Hz/ 60Hz (Auto detection) | ||||||||
Low Line Frequency Re-connect | 51+0.3Hz for 60Hz; 41+0.3Hz for 50Hz; | |||||||||
Low Line Frequency Disconnect | 50+0.3Hz for 60Hz; 40+0.3Hz for 50Hz; | |||||||||
High Line Frequency Re-connect | 64+0.3Hz for 60Hz; 54+0.3Hz for 50Hz; | |||||||||
High Line Frequency Disconnect | 65+0.3Hz for 60Hz; 55+0.3Hz for 50Hz; | |||||||||
main functions | Output Voltage Waveform | As same as Input Waveform | ||||||||
Over-Load Protection (SMPS load) | Air switch | |||||||||
Output Short Circuit Protection | Air switch | |||||||||
Max Bypass Overload Current | 40A/50A/80A | |||||||||
Battery Invert Mode Specifications: | ||||||||||
AC output | Output Voltage Waveform | Sine wave | ||||||||
Rated Output Power (KW) | LV:4KW/5KW/6KW | HV: 4KW/5KW/ 6KW/7KW/8KW/10KW | ||||||||
Power Factor | 0.9~1.0 | |||||||||
Nominal Output Voltage (V) | LV:120Vac ±10%rms | HV:230Vac ±10%rms | ||||||||
Nominal Output Frequency (Hz) | 60Hz ± 0.3Hz 50Hz ± 0.3Hz | |||||||||
DC Voltage | Nominal DC Input Voltage | 24VDC/48VDC | ||||||||
DC Voltage range | 20-31.0Vdc for 24VDC 40-62.0Vdc for 48VDC | |||||||||
Low Battery Alarm | 21.0Vdc ± 0.6Vdc for 24V battery 42.0Vdc ± 1.2Vdc for 48V battery | |||||||||
Low DC input Shut-down | 20.0vdc± 0.6Vdc for 24V battery 40.0Vdc ± 1.2Vdc for 48V battery | |||||||||
High DC input Alarm & Fault | 32Vdc ± 0.6Vdc for 24V battery 64Vdc ± 1.2Vdc for 48V battery | |||||||||
High DC input Recovery | 31.0Vdc ± 0.6Vdc for 24V battery 62.0Vdc ± 1.2Vdc for 48V battery | |||||||||
AC Charger | Nominal Charge Current | 35A/50A/70A (5 stages adjustable charging current) | ||||||||
Charge Current Regulation | ± 5Adc | |||||||||
Over Charge Protection | Bat.V≥31.0VDC for 24V battery Bat.V≥62.0VDC for 48V battery beeps 0.5s every 1s & fault after 60s | |||||||||
Algorithm | Three stage: Boost CC (constant current stage) → Boost CV (constant voltage stage) → Float (constant voltage stage) | |||||||||
Solar charger | Rated Charge Current | 40A | 60A | |||||||
Rated charge battery Voltage type | 24V/48V | 24V | ||||||||
Max.PV open circuit array voltage | 24V for 55Vdc 48V for 110Vdc | |||||||||
Charger mode | MPPT | |||||||||
PV Low Voltage Re-connect | PV≥Bat.V=3V | |||||||||
PV Low Voltage Disconnect | PV<=Bat.V | |||||||||
Efficiency | ≥97% | |||||||||
Efficiency | Efficiency (Battery Mode) | ≥85% | ||||||||
Efficiency (Line Mode) | >98% | |||||||||
Transfer Time | Ac to Dc | 20ms (Max) | ||||||||
Dc to Ac | 15ms (Max) | |||||||||
System parameter | Over-Load Protection | 110% <load<150%, beeps 0.5s every 1s, and Fault after 60s off the output, Load>150%, beeps 0.5s every 1s, and Fault after 20s. | ||||||||
Output Short Circuit Protection | Current limit (Fault after 10s) | |||||||||
Surge rating (10s) | 1:3 (VA) | |||||||||
Power saver | Load <=25W (Enabled on “P/S auto” setting of Remote control) | |||||||||
Protections | Low battery, over charging, over load , over temp. | |||||||||
Indicators | LED+LCD Display | |||||||||
General Specifications | Operating Temperature Range | 0°C to 40°C | ||||||||
Storage temperature | -15ºC ~60ºC | |||||||||
Operation humidity | 5% to 95%(non-condensing) | |||||||||
Audible Noise | 60dB max | |||||||||
Cooling | Forced air, variable speed fan | |||||||||
Dimension(L*W*H) | 4KW | 5KW | 6KW | 7KW | 8KW | 10KW | ||||
530*400*190mm | 590*420*195mm | |||||||||
Net weight(Kg) | 30.0 | 35.5 | 38.5 | 41.5 | 48.0 | 55.0 |
Product picture
FAQ
Q.What is the function of an inverter?
A.It basically converts dc to ac. They are primarily used to convert the dc current from batteries to ac supply.Typically used in power backup systems for when the mains power fails. Small inverters are also sold as camping equipment to convert motor vehicle battery power to AC for low power applications such as powering lamps and portable TVs.
Q.How many kinds of output wave form for inverters?
A.Two kinds. Pure sine wave and modified sine wave. Pure sine wave inverter could provide high quality AC and carry various loads, while it requires high tech and high cost. Modified sine wave inverter load poorly not carrying inductive load, but the price is moderate.
Q:What's the difference between Low Frequence Inverter and High Fequency Inverter?
A: Low frequency inverter is far better than almost all high frequency inverter. Low frequency 2kw inverter using traditional analog circuits principle for design.The transformer,inductor and capacitor will be big size and highest quality to ensure it's strong loading capacity. So it can work in pretty harsh electric environment, absolutely it will be more reliable and stable ! And high frequency just use the software programs in Micro CPU Chip to control the UPS, the size will be smaller and the production costs will be more lower.
Q.What should be noticed when installing inverter?
A.Put the product in a place where is well ventilate,cool, dry and water-proof. Pls do not stress and do not put foreign objects into the inverter.Rember to turn on the inverter before turn on the appliance.
Q.If your product is broken down,do you provide warranty?
A.Yes,of course.We provide two years warranty.