* Please refer to users manual for more detailed and up-to-date description of specification |
|
AC Watt (50 or 60 Hz, PF 0.5 to 1, CT=1) | Range | Resolution | Accuracy of Readings | 6800+6801 | 6800+6802 | 6800+3007 | 5.0 – 999.9W | 0.1W | ±1% ± 8dgts | ±1% ± 8dgts | ±1% of VA Range ±8dgts | 1.000 – 9.999 KW | 0.001 KW | ±1% ± 8 dgts | ±1% ± 8 dgts | ±1% of VA Range ±8dgts | 10.00 – 99.99 KW | 0.01 KW | ±1% ± 8 dgts | ±1% ± 8 dgts | ±1% of VA Range ±8dgts | 100.0 – 999.9 KW | 0.1 KW | ±1% ± 8dgts | ±1% ± 8dgts | ±1% of VA Range ±8dgts | 1000 – 9999 KW | 1 KW | ±1% ± 8dgts | ±1% ± 8dgts | ±1% of VA Range ±8dgts | 0.000 – 9.999MW | 0.001MW | – | ±1% ± 8 dgts | ±1% of VA Range ±8dgts |
|
AC Current( 50 or 60Hz, Auto Range,True RMS,Crest Factor<4,CT=1) | | Range | Resolution | Accuracy of Readings | 6830+6801 (Overload Protection AC200A) | 0.050 – 9.999A | 0.001A | ±0.5% ± 5dgts | 10.00 – 60.00A | 0.01A | ±0.5% ± 5dgts | 60.00 – 99.99A | 0.01A | ±1.0% ± 5dgts | 6830+6802 (Overload Protection AC2000A) | 0.04 – 10.00A | 0.01A | – | 0.4A – 100.0A | 0.1A | ±0.5% ± 5dgts | 4.0 – 1000.0A | 1A | ±0.5% ± 5dgts | 6830+3007 (Overload Protection AC3500A) | 4 – 300A | 0.1A | ±1% of Range ±5dgts | 300.0 – 999.9A | 0.1A | ±1% of Range ±5dgts | 1000 – 3000A | 1A | ±1% of Range ±5dgts |
|
AC Voltage (50 or 60 Hz, Auto Range, True RMS, Crest Factor<4) | Range | Resolution | Accuracy of Readings | Range | Resolution | Accuracy of Readings | 4.0V – 500.0 (Phase to Neutral) | 0.1V | ± 0.5% ± 5dgts | 4.0V –600.0V (Phase to phase) | 0.1V | ± 0.5% ± 5dgts |
|
Harmonics of AC Voltage in % and in Magnitude (1 to 99th order, minimum voltage at the 50 or 60 Hz>AC 80V) | Range | In Percentage | In Magnitude | Resolution | Accuracy of readings | Resolution | Accuracy of readings | 1 – 20 th | 0.1% | ±2% | 0.1 V | ±2% ±0.5V | 21 – 49 th | 4% of reading ±2.0% | 4% of reading ±0.5A | 50 – 99 th | 6% of reading ±2.0% | 6% of reading ±0.5A |
|
Harmonics of AC Current in % and in Magnitude Model 6830+6801(100A)(1 to 99th order, minimum current at 50 or 60 Hz is greater than 10% of the range) | Range | In Percentage | In magnitude | Resolution | Accuracy of reading | Resolution | Accuracy of reading | 1 – 10 th | 0.1% | ±0.2 of reading ±1% | 0.1mA / 0.1A | ±0.2% of reading ±7dgts | 11 – 20 th | ±2% of reading ±1% | ±2% of reading ±7dgts | 2 1 – 50 th (A range) | ±5% of reading ±1% | ±5% of reading ±7dgts | 2 1 – 50 th (mA range) | ±10% of reading ±1% | ±10% of reading ±7dgts | 5 1 – 99 th | ±35% of reading ±1% | ±35% of reading ±7dgts |
|
Model 6830+6802(1000A);6830+3007(3000A)(1 to 99th order, minimum current at the 50 or 60 Hz>20A) | Range | In Percentage | In Magnitude | Resolution | Accuracy of reading | Resolution | Accuracy of reading | 1 – 20 th | 0.1% | ±2% | 0.1A(6802) / 0.3A(3007) | ±2% of reading ±0.4A/0.6A | 21 – 49 th | 4% of reading ±2.0% | ±4% of reading ± 0.4A/0.6A | 50 – 99 th | 6% of reading ±2.0% | ±6% of reading ± 0.4A/0.6A |
|
Total Harmonic Distortion | Range | Resolution | Accuracy(6801) | Accuracy(6802) | Accuracy(3007) | 0.0 – 20% | 0.1% | ±1% | ±2% | ±2% | 20 – 100% | 0.1% | ±3% of reading ±5% | ±6% of reading ±1% | ±6% of Range ±1% | 100 – 999.9% | 0.1% | ±10% of reading ±10% | ±10% of reading ±1% | ±10% of Range ±1% |
|
Peak Value of Ac Voltage or AC Current ,VT=1 | Range | Sampling Time | Accuracy of reading | 50Hz | 39 μS | ±5% ±30digits | 60Hz | 33 μS | ±5% ±30 digits |
|
Crest Factor (C.F.) of ACV or ACA ,VT=1 | Range | Resolution | Accuracy of reading | 1.00 – 99.99 | 0.01 | ±5% ±30digits |
|
Range | Resolution | Accuracy of reading | 45 – 65Hz | 0.1Hz | 0.1Hz |
|
Range | Resolution | Accuracy of reading | 0.00 – 1.00 | 0.01 | ± 0.04 |
|
Range | Resolution | Accuracy of reading | -180 to 180 | 0.1 | ± 1 |
|
Conductor Size (6801) | 30mm (approx) | Conductor Size (6802) | 55mm(approx.), 64 X 24mm(Bus Bar) | Battery Type | 1.5V SUM-3 x 8 | Display | Dot Matrix LCD with backlight | Power Consumption | 140mA (approx.) | External DC Input | DC 12V adaptor (for safety purpose, the adaptor must be certified with 600Visolation protection) | LCD update rate | 1 times / sec | No. Of Samples/Period | 1024 | Operating Humidity | < 85% relative | Operating Temperature | -10°C to 50°C | Storage Humidity | < 75% relative | Storage Temperature | - 20°C to 60°C | Weight(6830) | 1160g | Weight(6801) | 200g | Weight(6802) | 600g | Dimension(6830) | 257 (L) x 155 (W) x 57 (H) mm ,10.1"(L) x 6.1" (W) x 2.3" (H) | Dimension(6801) | 210 (L) x 62 (W) x 36 (H) mm ,8.3 " (L) x 2.5" (W) x 1.4" (H) | Dimension(6802) | 244 (L) x 97 (W) x 46 (H) mm ,9.6 " (L) x 3.8" (W) x 1.8" (H) | Accessories | Test leads x 4,alligator clips x 4,Carrying bag x 1,Users manual x 1,Batteries 1.5V x 8 |
|