Handheld ultrasonic water flow meter clamp-on sensors to measure liquid flow. Installation process is very simple, all Chinese human-machine interface, more easy to operate. Particularly suitable flow balance testing and flow monitoring: drinking water, river water, sea water, cooling water, hot water, industrial waste water, lubricating oil, diesel oil, fuel oil, chemical liquids.
The principle of ultrasonic water flow meter:
1) Time difference measuring principle: a probe transmission signal after passing through the wall, the media, the other side of the wall, another probe is received, while the second probe, also launched a probe signal is first received, due to the media the impact velocity, there is a time difference Δt between the two, according to projections can be drawn in terms of the relationship between flow velocity V, and the time difference Δt between V = (C2 / 2L) × Δt, in turn, can obtain flow values Q.
2) Measuring principle: difference correlation principle flow rate: 0.01 ~ 25 m / s Resolution: 0.025 cm / s Repeatability: 0.15% of reading, depending on the application accuracy :( fully developed flow field and radially symmetric) Volume flow: ± 1% reading, depending on the application ± 0.5% of reading, calibrated flow rate: ± 0.5% of reading, depending on the application can be measured media: all acoustically conductive fluid, and the volume content of bubbles or solid particles of <10%
About the Ultrasonic Flow Meter:1.Handheld ultrasonic flow meter 2.portable ultrasonic flow meter 3.wall mounted ultrasonic flow meter and Pipeline ultrasonic flow meter.