1.Five detectors are optional
Detectors | Application range | ||||
Thermal Conductivity Detector (TCD) | Constant Analysis for Gases and Liquids | ||||
Hydrogen Flame Ionization Detector (FID) | Organic matter analysis in the hydrocarbon industry and other fields | ||||
Flame Photometric Detector (FPD) | Detection of trace sulfur and phosphorus compounds | ||||
Nitrogen and Phosphorus Detector (NPD) | Detection of trace sulfur and phosphorus compounds | ||||
Electron Capture Detector (ECD) | Detection of compounds that capture electrons |
2. Unit-type overall structure design, easy to install and maintain
3. Large volume oven, can install three columns at the same time
4. The instrument design is reasonable and flexible. It can install any three detectors at the same time, and has three independent circuit systems and three signal outputs.
5. Flexible packed column and capillary column system, can be connected to different diameter capillary columns.
6. Stable temperature control system, 10th-order temperature programming, injector and detector can independently control temperature, and have over-temperature protection function; heating zone can control temperature of seven channels
7. Host through the workstation automatic ignition analysis
8. Automatic rear door opening control to speed up the cooling rate (optional)
9. New regulated, multi-pneumatic system: single, dual, and three gas paths (optional), 3-way pressure flow digital display, pressure display resolution 0.1pis
Detection limit | Noise | Linear range | Drift | |
TCD | Sensitivity≥8000mv.ml/mg(benzene) | ≤0.1mv | ||
FID | M≤1×10-11g/sec (n-hexadecane) | ≤5×10-14A | 1×107 | 1×10-13A/30min |
ECD | M≤1×10-13g/ml(r-666) | ≤0.01mv | 1×104 | 0.02mv/30min |
FPD | Mp≤2×10-12g/s(1605) Ms≤5×10-11g/s (thiophene) | ≤2×10-12A | 1×104 | 4×10-12A/30min |
NPD | Mn≤5×10-13g/s Mp≤1×10-12g/s | ≤2×10-13A | 1×104 | 2.5×10-12A/h |
1.OVEN
Oven volume | 300 × 300 × 200mm | ||||
Temperature range | room temperature +5 ° C ~ 420 ° C | ||||
Temperature accuracy | 1% of the set value | ||||
Temperature control accuracy | ±0.1 °C | ||||
Overheat protection | can set any temperature within 420 °C | ||||
Running time | 24 hours continuous operation |
2. Large-screen LCD display, showing temperature, external events, operating conditions, etc.
3. Temperature program
Program order: man-machine dialogue setting constant temperature or 10th-order program temperature
Heating rate: 0-40 ° C / min (increment 0.1 ° C / min)
Temperature repeatability: ≤0.2%
4. Injection method
Capillary split/splitless injection, packed column injection, cold on-column injection (up to 3 inlets can be installed at the same time)