MARINE GENERATOR WITH CUMMINS ENGINE MODEL: CCFJ-250J5
50HZ
MARINE POWER
MARINE DIESEL GENERATING SET 400/230 V - 50 Hz - 3PHASE
POWER RATING | PRIME POWER | STANDBY POWER | |
Power | KVA | 313 | 344 |
KW | 250 | 275 | |
Rated Speed | r.p.m | 1500 | |
Standard Voltage | V | 400 | |
Available Voltages | V | 400/230 - 380/220-415/240V-440/254 etc | |
Rated at power factor | Cos Phi | 0.8 |
P.R.P. Prime Power - ISO 8528 : Prime power is the maximum power available during a variable power sequence, which may be run for an unlimited number of hours per year,between stated maintenance intervals. The permissible average power output during a 24 hours period shall not exceed 80% of the prime power.
Standby Power (ISO 3046 Fuel Stop power): power available for use at variable loads for limited annual time (500h), within the following limits of maximum operating time: 100% load 25h per year – 90% load 200h per year. No overload available.
ENGINE | PRIME | STANDBY | |||
Rated Output | KW | 284 | 321 | ||
Engine Manufacturer | Cummins | ||||
Model | NTA855-D(M) | ||||
No. of Cylindirs and Build | 4 Cycle, 6 Cylinder in Line | ||||
Aspiration and Cooling | Turbocharged/Aftercooled | ||||
Bore/Stroke | mm | 140X152 | |||
Compress the ratio | 14.0:1 | ||||
Cooling system | Water-cooled | ||||
Engine Speed/Frequency | rpm/Hz | 1500/50HZ | |||
Starting System | Electric 24 volt DC | ||||
Displacement | L | 14 | |||
Lubricant system Capacity | L | 30 | |||
Battery Volatge / Capacity | 24VDC | ||||
Governing Type | Type | Electronic | |||
Air Filter | Type | Dry | |||
Fuel Consumption | Load | 100% | 75% | 50% | 25% |
L/H | 70 | 53 | 36 | 19 |
ENGINE--Industrial 4 stroke cooled diesel engine complete with air,fuel and oil filters,electric starting and charging equipment,engine protection against low water level.
COOLING--Radiator and colling fan complete with protection guards,designed to cool engine at specified output in air temperatures upto 50 ℃,radiators suitable for higher temperatures are available.Low water level protection fitted as standard.
ELECTRICAL SYSTEM--24V upto.Axial type starter motor,battery charging alternator,high capacity lead acid battery,and battery tray mounted on the generator base frame,and heavy duty interconnecting cable with terminations.
EXHAUST SYSTEM--Heavy duty industrial exhauset silencer with flexible piping.
ALTERNATOR BRAND | STAMFORD | Marathon | |
Model | S4L1M-E4 | MP-H-250-4 | |
Exciter System | Self-excited, brushless | ||
Poles | Numbers | 4 | |
Connection Type | Reconnectable | ||
Insulation Type | Class | Class H | |
Voltage Regulator | A.V.R. (Electronic) | ||
Steady Voltage Precision | ± 1% | ||
Underspeed Protection | Standard | ||
Overexcitation Protection | IP23 | ||
TIF (1960 Weightings) | <50 |
ALTERNATOR--Brushless,self exciting,self regulation,sreen protected,drip proof rated in accordance with IEC60034.Voltage regulation maintainted within ±0.5% from no load to full load.between 0.8 lagging and unity.All standard voltages available.
AMF Control Panel- ComAp AMF9 Or DSE7320
Main Features:
ΔAutomatic mains failure
ΔEngine control,Generator protection
ΔBuilt in alarms and warnings
ΔRemote Start operation available
ΔWeekly operation schedule programs
DISPLAY:Engine speed,Oil pressure,Coolant temperature,Run time,Battery volts,Voltage (L-N),Current (L1-L2-L3),Frequency,MAINS
WARNING:Battery charge failure, Low battery voltage,SHUT DOWNS,Fail to start,Emergency stop,Low oil pressure,High engine temperature,Over /Under speed,Under/over generator frequency,Failed to reach loading voltage,ELECTRICAL TRIP.
Voltage Regulation:
Voltage regulation maintanined within ±0.5% From no load to full load
Between 0.8 and 1.0 lagging and unity At speed droop variation upto 4.5%
Frequency Adjustable Ratio:
Change load from 0-100%,within 1.0%( electric speed regulator),within 4.5%( mechanical speed regulator)
Frequency Undulation:
Load from 0-100%,frequency undulation within 0.25% Effect factor of Telecom
No load wire volts max undulation ration\ within 1.8% TIF better than 50
Three Phrase balanced load in the order of 5% THF to IEC60034 Part 40 better than 2%
Generating Sets Optional Features:
ΔLow fuel level alarm shutdown ΔAuto Transfter Switch( ATS)
ΔAutomatic Fuel Filling System ΔParallel control panels
ΔEngine oil feeding and drain pump ΔTrailer type Gensets
Quality Standards:
ISO9001:2000,ISO14000,ISO3046 BS5514,AS1359,ICE34
ISO8528 BS4999 CE Compliance
Gensets Dimensions & Weight:
Open type:LxWxH (mm) Net Weight Kgs: 2800*1000*1800, 3100kgs
Factory and Production facilities:
FUZHOU PIRME POWER CO.,LTD
Whatsapp/ Wechat/ Mobile:008613705041170
www.primepowergenset.com
Skype:sunshinebenjamin
PRIME POWER reserves the right to modify the characteristics of its product at any time in order to incorporate the latest technological developments.The information contained in this document may therefore be changed without notice.