Optical Transmission Network SDH Equipment Huawei OptiX OSN 8800 T16
♥ OptiX OSN 8800 T16 is mainly applicable to the metropolitan convergence layers.
The OptiX OSN 8800 T16 can be used with the metropolitan DWDM equipment, SDH equipment, and data communication equipment at the backbone layer to provide a large-capacity transport channel for services and network egresses. The OptiX OSN 8800 T16 applies to the long-distance and large-capacity transmission of nation-level trunk and inter-province trunk to maximally meet the requirements of large-capacity and ultra-long haul transmission for carriers. In addition, the OptiX OSN 8800 T16 provides carriers with a stable platform for multi-service operation and future network capacity expansion.
♥ The OptiX OSN 8800 T16 use dense wavelength division multiplexing (DWDM) technologies to achieve transparent transmission with multiple services and large capacity. It not only provides service grooming at the optical layer on a wavelength basis by using the ROADM technology, but also provides sub-wavelength grooming based on ODUflex/ODU3/ODU2/ODU1/ODU0. This improves the flexibility in service grooming and
bandwidth utilization to a great extent.
♥ The OptiX OSN 8800 can interconnect with the OptiX OSN 6800/OptiX OSN 3800/OptiX
OSN 1800 to form an end-to-end OTN network. Also, they can interconnect with the OptiX
BWS 1600G to form a WDM network. Typically, the OptiX OSN 8800 is applied to the OTN
network.
1.Appearance
1. Board area 2. Fiber cabling area 3. Fan tray assembly
4. Air filter 5. Fiber spool 6. Mounting ear
• Board area: All the boards are installed in this area. 24 slots are available.
• Fiber cabling area: Fiber jumpers from the ports on the front panel of each board are routed to the fiber cabling area before being routed on a side of the open rack.
• Fan tray assembly: Fan tray assembly contains ten fans that provide ventilation and heat
dissipation for the subrack. The front panel of the fan tray assembly has four indicators
that indicate fan status and related information.
2.Slot Distribution
The board area and interface area of the OptiX OSN 8800 T16 subrack provide 25 slots.
3.Functional Board
4.Product Feature
As a one-box product (OTN+OCS), the equipment integrates functions such as WDM transport, ROADM, 40G, cross-connections of any granularity in the range of 100M to 40G, ASON, and rich management and protection.
♦ The equipment is of high integration, which enables flexible service configuration. A network built with the equipment is easy to design, to expand, and to maintain, and requires a smaller number of spare parts.
♦ The equipment supports access of massive services and centralized cross-connections and management of the services. This avoids assembly of multiple subracks. The equipment is of high integration. For example, one PID chip is integrated with tens of photoelectric components to achieve 12 x 10G transmission.
♦ When used as an 80/40-channel system, the OptiX OSN 8800 supports:
♦ The OptiX OSN 8800 CWDM systems support service access over eight wavelengths. Each wavelength supports a maximum rate of 2.5 Gbit/s.
♦ The ASIC and PID technologies enable design of a board with high density and help reduce power consumption of each port. Ultra cross-connections help reduce bridging at many ODF and also save space in telecommunications rooms.
DC: –48/–60V The OptiX OSN 8800 T16 supports centralized cross-connections through a cross-connect board. The OptiX OSN 8800 T16 provides one type of cross-connection boards, that is, XCH. It supports hybrid cross-connections of ODU0, ODU1, ODU2, ODU3, and ODUflex signals, and supports a 640 Gbit/s cross-connect capacity to the maximum
Dynamic intra-ring grooming and inter-ring grooming can be realized using the ROADM board.
Dynamic optical layer grooming can be classified into intra-ring grooming and inter-ring grooming, or into two-dimensional grooming and multi-dimensional grooming.
Dimension refers to transmission direction. Two-dimensional grooming refers to wavelength grooming in two transmission directions. Multi-dimensional grooming refers to wavelength grooming in multiple transmission directions
• Flexible Electrical-Layer Cross-Connections
The equipment supports non-blocking electrical cross-connections, centralized cross-connections of massive services, and complex networking.
The ODUk sub-wavelengths can be flexibly combined to share 10G/40G line bandwidth for transmission. This enables uniform carrying of any services over one wavelength and therefore improves wavelength utilization to a great extent.
Bandwidth is tailored for services. This improves the efficiency of transmission bandwidth and achieves "zero waste" of bandwidth.
• Hybrid O/E Cross-Connections and Quick Service Deployment
Hybrid O/E cross-connections achieve flexible cross-connections of wavelength or sub-wavelength services. Quick service deployment helps reduce CapEx. On a flattened network, services are easy to plan, deploy, and expand. Much less time needs to be taken to provision a service.
• High Reliability
The tributary/line separated structure maximizes the return on investment and reduces the number of spare parts. When service type changes, users only need to replace the tributary boards but fully reuse the existing line boards. The use of independent line and tributary boards reduces the number and type of spare parts from N x M to N + M (N, M > 2), thereby helping operators reduce construction costs.
• Rich OAM, Easy Maintenance, and Lower OpEx
♦The rich O/E overhead information on OTN equipment leads to a more transparent network, facilitates fault identification, and helps reduce maintenance costs.
♦The PRBS function enables quick self-check of OTUs, quick assessment of channel performance, and quick fault identification.
♦The "5A" auto-adjustment function:
♦Support monitor channel power, central wavelength, OSNR, and overall optical spectrum, and
also supports remote real-time measurement of optical spectrum parameters.
6.Specification
OptiX OSN 8800 | ||
---|---|---|
Dimensions (H*W*D) | 450mm×498mm ×295 mm | |
Number of Slots | 16 | |
Cross-Connect Capability | Optical | 2/4/9-degree ROADM, colorless and directionless |
Electrical | 640G/1.6T ODUk (k = 0, 1, 2, 2e, 3)/ODUflex integrated electrical cross-connection |
|
Number of Wavelengths | 40/80 | |
Wavelength Range | 192.1 THz to 196.05 THz (Band-C, ITU-T G.694.1) | |
Max. Rate per Channel | 100 Gbit/s (OTU4) | |
Reach | 40G transmission over 2,000 km without REG, 10G transmission over 5,000 km without REG, and 1 x 72 dB single hop by 40G, 1 x 82 dB single hop by 10G |
|
Client-Side Interface | Service Type | STM-1/4/16/64/256 OC-3/12/48/192/768 OTU1/OTU2/OTU2e/OTU3/OTU3e FE/GE/10GE/ESCON/FICON/FICONExpress/FC100/FC200/FC400/FC1200/ HDTV/DVB-ASI/DVB-SDI/SDI/FDDI |
Fiber Type | G.652, G.653, G.654, G.655 | |
WDM-Side Interface | Service Type | OTU1/OTU2/OTU3/OTU4 (2.5/10/40/100 Gbit/s) |
Fiber Type | G.652, G.653, G.654, G.655 | |
Topology | Point-to-point, chain, ring, and mesh | |
Synchronization | IEEE 1588v2 clock and synchronous Ethernet | |
Protection | Hardware | XCS/SCC/STG in one board (XCH) with 1+1 backup, power board 1+1 backup |
Protocol | OTN network level protection: optical line protection, optical channel protection, ODUk (k = 0, 1, 2, 3)/ODUflex SNCP protection, ODUk (k = 0, 1, 2, 3) SPRing protection, optical wavelength shared protection (OWSP) |
|
ASON | Optical and electrical ASON, providing higher reliability up to 99.9999% | |
Installation | ETSI 300 cabinet, 23-inch rack with four subracks |
|
Operating temperature | –5°C to 45°C (typical) –40°C to 65°C (specific configuration) |
|
Cooling | Fan cooling | |
Relative Humidity | 10% to 90% | |
Power Supply | DC: –48/–60V | |
Power Consumption | 700 w (typical) |
7.Other product information
Trade Information
1) Trade terms: FOB,CIF,CFR,etc
2) Price Terms: L/C,D/P,T/T,Western Union,PAYPAL
3) Payment Terms: T/T in advance
4) Port: Shanghai
5) Lead time: Within 7 working days after receipt payment.
6) Shipment: Express, Air, Sea
7) Sample availability: Yes( not free)
After-Sales Service
1) We can provide detail documents and remote help for device installation and configuration.
2) Warranty: 1 year. ( After the quality guarantee period began to charge appropriate maintenance service fee.)
3) Our company promises goods enjoy full return due to quality problem since goods delivered within 7 days or 15 days , returned goods must keep original state and it’s accessories are complete.