Specifications
MODEL | EP30-1KW PLUS | EP30-1.5KW PLUS | EP30-2KW PLUS | EP30-3KW PLUS | EP30-4KW PLUS | EP30-5KW PLUS | EP30-6KW PLUS | |||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Default Battery System Voltage | 12VDC | 24VDC | 12VDC | 24VDC | 12VDC | 24VDC | 24VDC | 48VDC | 24VDC | 48VDC | 48VDC | 48VDC |
INVERTER OUTPUT | ||||||||||||
Reted Power | 1.0KW | 1.5KW | 2KW | 3KW | 4KW | 5KW | 6KW | |||||
Surge Rating (20ms) | 3.0KVA | 4.5KVA | 6.0KVA | 9.0KVA | 12KVA | 15KVA | 18KVA | |||||
Capable Of Starting Electric Motor | 1HP | 1.5HP | 2HP | 3HP | ||||||||
Waveform | Pure sine wave/ same as input (bypass mode) | |||||||||||
Nominal Output Voltage RMS | 220V/230V/240VAC(±10% RMS) | |||||||||||
Output Frequency | 5OHz/60Hz±0.3 Hz | |||||||||||
Inverter Efficiency(Peak) | >85% | |||||||||||
Line Mode Efficiency | >95% | |||||||||||
Power Factor | 1.0 | |||||||||||
Typical Transfer Time | 10ms(max) | |||||||||||
AC INPUT | ||||||||||||
Voltage | 230VAC | |||||||||||
Selectable Voltage Range | 96~132VAC 155~280VAC(For Personal Computers) | |||||||||||
Frequency Range | 50Hz/60Hz (Auto sensing) 40~80Hz | |||||||||||
BATTERY | ||||||||||||
Minimum Start Voltage | 10.0VDC /10.5VDC for12VDC mode (*2 for 24VDC,*4 for 48VDC ) | |||||||||||
Low Battery Alarm | 10.5VDC±0.3V for12VDC mode (*2 for 24VDC,*4 for 48VDC ) | |||||||||||
Low Battery Cutoff | 10.0VDC±0.3V for12VDC mode (*2 for 24VDC, *4 for 48VDC) | |||||||||||
High Voltage Alarm | 16.0VDC±0.3V for12VDC mode (*2 for 24VDC, *4 for 48VDC) | |||||||||||
High Battery Voltage Recover | 15.5VDC±0.3V for12VDC mode | |||||||||||
Idle Consumption-Search Mode | <25W when power saver on | |||||||||||
CHARGER | ||||||||||||
Output Voltage | Depends on battery tvpe | |||||||||||
Charger AC Input Breaker Rrating | 10A | 30A | 30A | 30A | 40A | |||||||
Overcharge Protection S.D. | 15.7VDC for 12VDC mode (*2 for 24VDC mode,*4 for 48VDC mode) | |||||||||||
Maximum Charge Current | 35A | 20A | 45A | 25A | 60A | 30A | 40A | 20A | 60A | 30A | 35A | 40A |
BYPASS & PROTECTION | ||||||||||||
Input Voltage Waveform | Sine wave (grid or generator) | |||||||||||
Nominal Input Frequency | 50Hz or 60Hz | |||||||||||
Overload Protection (SMPS Load) | Circuit breaker | |||||||||||
Output Short Circuit Protection | Circuit breaker | |||||||||||
Bypass Breaker Rating | 10A | 30A | 30A | 30A | 30A | 40A | ||||||
Max Bypass Current | 30Amp | |||||||||||
MECHANICAL SPECIFICATIONS | ||||||||||||
Mounting | Wall mount | |||||||||||
Dimensions (W*H*D) | 426*206*178 mm | 601*206*178 | ||||||||||
Net Weight (Solar CHG) kg | 16.5 | 17 | 21.1 | 20 | 24.5 | 24.8 | 38.2 | 35.8 | 45 | 45 | ||
Shipping Dimensions(W*H*D) | 570*335*300mm | 750*335*300mm | ||||||||||
Shipping Weight (Solar CHG) kg | 19.3 | 20 | 24.1 | 22.8 | 27.5 | 27.5 | 42.3 | 40 | 49.3 | 49.3 | ||
OTHER | ||||||||||||
Operation Temperature Range | 0°C to 40°C | |||||||||||
Storage Temperature | -15°C to 60°C | |||||||||||
Audible Noise | 60dB MAX | |||||||||||
Display | LED+LCD | |||||||||||
Standard Warranty | 1 year |
Do you know MUST POWER LIMITED?
Q1: How to choose a right inverter?
A1:Tell us your demand, then our sales will recommend a suitable inverter to you.
Q2: What's the different between inverter and solar inverter?
A2: Inverter is only accept AC input, but solar inverter not only accept AC input but also can connect with solar panel to accept PV input, it more save power.
Q3: How about the delivery time?
A3: 7 days for sample; 25 days for bulk order.
Q4: What is the warranty of inverter?
A4: One year warranty on Must-Solar product.
Q5: How to solve the technical problem?
A5: 24 hours after-service consultancy just for you and to make your problem to solve easily.