1.Overall dimensions of the instrument
|
510*380*415mm(W*D*H)
|
2.Test space
|
360mm×330mm×100mm(W*D*H) Visualize the sample bin and observe the sample during the test
|
3.Spot size
|
Φ0.1mm,Φ0.3mm,Φ0.7mm,Φ1.2mm,Φ2mm,Φ5mm,Φ7mm
|
4.Weight
|
|
5.Working temperature
|
|
6.Working Relative humidity:
|
≤75% (non-condensing)
|
7.Test element range:
|
elements in S-U
|
8.Function description
|
Can be applied to RoHS directive, halogen-free directive, WEEE directive, ore, alloy analysis; Pb (lead), Cd (cadmium), Hg (mercury), total Cr (chromium) and halogen total Br (bromine) in electronic and electrical plastic products , Cl (chlorine) element control.
|
9.Types of analysis samples
|
Solid, liquid, powder, paste, etc .;
|
10.Test range:
|
1ppm—99.99%
|
11.Measurement time
|
60-240s (software automatic adjustment)
|
12.Warranty period
|
Two-year warranty (14 months), including three core components: X-ray Tube, detector, high voltage power supply.
|
13.Detector
|
Amptek X-123, resolution 145eV, full set of original imported integrated (probe + digital pulse processor)
|
14.X-ray tube
|
The maximum power is 50W, molybdenum target side window X-ray tube (Be), service life: more than 20,000 hours.
|
15.High voltage power supply
|
Maximum power 50W (50kV, 2mA) (0 ~ 2mA continuously adjustable)
|
16.Input power supply
|
AC 220V±10%,50Hz
|
17.Maximum power
|
330W
|
18.Filter / collimator
|
6 kinds of composite filters; 6 kinds of collimators; automatic switching;
|
19.Camera
|
5 million pixels
|
20.Software algorithm
|
Empirical coefficient method, internal standard method, standard curve method, basic parameter method
|
22.Software operating system
|
Open analysis model function, triple-ray protection system (software, hard Parts, labyrinth design), automatic warning system for opening test, self-protection for overvoltage Protection, self-recovery. Circuit hardware safety interlock, misoperation 0.1uS fast cut X-ray source
|
23.Report format
|
WORD, PDF, EXCEL, report format can be set according to customer needs.
|
24. Sample shape:
|
Solid, liquid, powder, etc., not limited
|
25. Sample thickness:
|
Not limited
|
26. Test requirements (features)
|
1.Positionable test; 2. The test completion software automatically determines whether it is qualified or not, and automatically exports the test report with product pictures and spectrum diagrams; 3. There is a spectrum of the test elements and a spectrum comparison function.
|
27.Sample test diameter:
|
Φ0.1mm—Φ25mm optional
|
28.Analytical detection limition:
|
1ppm
|
29.RoHS measurement accuracy:
|
The measurement accuracy deviation of samples around 1000ppm is ± 50ppm; around 100ppm is ± 10ppm; the maximum detection limits of Cr, Hg, Pb, and Cd are ≤2ppm
|